ABB 1SDA059324R1 E2S1000 is a 1000 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LSIG R1000 electronic trip unit providing overload, short-circuit and earth-fault protection.
£11,534.72
The ABB E2S1000 PR122/P-LSIG, order code 1SDA059324R1, is a high-performance 1000 A four-pole withdrawable air circuit breaker moving part designed for switching and protecting demanding low-voltage power distribution systems. As part of the proven ABB SACE Emax E2S series, it combines robust high-current switching capability with comprehensive electronic overcurrent and earth-fault protection for industrial, commercial and infrastructure switchgear.
This Emax circuit breaker is equipped with the PR122/P-LSIG R1000 electronic trip unit, providing long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. Its adjustable protection functions support selective coordination while helping safeguard cables, busbars, transformers, switchgear and connected equipment against overload, short-circuit and earth-fault conditions.
With a rated uninterrupted current of 1000 A, rated voltage of 690 V AC and an ultimate short-circuit breaking capacity of 85 kA at 400 V AC, the E2S1000 is suited to demanding distribution systems with high prospective fault currents. This model is supplied as the four-pole moving part of a withdrawable circuit breaker and includes four auxiliary contacts with open/closed position indication for integration into compatible SACE Emax switchgear.
Air circuit breakers such as the ABB SACE Emax E2S are designed to switch and protect high-current low-voltage distribution circuits. The electronic trip unit monitors circuit conditions and initiates breaker operation when configured protection thresholds are exceeded, helping safeguard cables, busbars, transformers, switchgear and connected equipment against damaging overload, short-circuit and earth-fault conditions.
The PR122/P-LSIG release provides long-time, short-time, instantaneous and earth-fault protection with adjustable settings for coordinated distribution protection. Combined with the E2S high short-circuit performance level and four-pole withdrawable construction, the E2S1000 is well suited to critical installations where strong fault interruption capability, neutral switching and service-friendly breaker removal are required.
| Series | SACE Emax |
|---|---|
| ABB order code | 1SDA059324R1 |
| EAN | 8015644616854 |
| Product group | 310513-New Emax |
| Customs tariff number | 85362090 |
| Product type | Air circuit breaker moving part |
| Frame / subtype | E2 |
| Short-circuit performance level | S |
| Rated current (In) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Number of poles | 4 |
| Current type | AC |
| Rated voltage | 690 V AC |
| Trip unit | PR122/P-LSIG R1000 |
| Release type | Electronic |
| Protection functions | L (overload), S (short-time short-circuit), I (instantaneous short-circuit) and G (earth fault) |
| Overload release adjustment range | 400–1000 A |
| Short-time short-circuit release adjustment range | 600–10000 A |
| Instantaneous short-circuit release adjustment range | 1500–15000 A |
| Rated ultimate short-circuit breaking capacity (Icu) | 85 kA at 400 V AC, 50 Hz |
| Integrated earth-fault protection | Yes |
| Version | Withdrawable moving part |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Circuit breaker open / closed |
| Trip indication | Available |
| Motor drive | Optional |
| Integrated motor drive | No |
| Protection rating | IP2X |
| Net weight | approx. 73 kg |
The ABB 1SDA059324R1 is a 1000 A four-pole SACE Emax air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution circuits.
This circuit breaker is equipped with the ABB PR122/P-LSIG R1000 electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and integrated earth-fault protection.
The E2S1000 has a rated ultimate short-circuit breaking capacity of 85 kA at 400 V AC, 50 Hz, making it suitable for demanding low-voltage distribution systems with high prospective fault currents.
The 1SDA059324R1 is the moving part of a four-pole withdrawable air circuit breaker, designed for use with the appropriate compatible SACE Emax fixed part.
LSIG denotes long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, providing comprehensive electronic protection for low-voltage distribution circuits.
ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining robust switching performance, comprehensive electronic protection and service-friendly withdrawable construction for demanding industrial and commercial switchgear.