ABB 1SDA059274R1 SACE Emax E2N 1000 A three-pole withdrawable air circuit breaker moving part with PR122/P-LSI R1000 electronic protection for demanding low-voltage power distribution systems.
£8,183.99
The ABB 1SDA059274R1 is a SACE Emax E2N 1000 air circuit breaker moving part designed for protection and switching in demanding low-voltage power distribution systems. Rated at 1000 A, this three-pole withdrawable breaker is equipped with an ABB PR122/P-LSI R1000 electronic overcurrent release for dependable overload and short-circuit protection.
As part of the ABB SACE Emax range, the E2N 1000 combines substantial short-circuit performance with a serviceable withdrawable construction. The 1SDA059274R1 is supplied as the withdrawable moving part (W MP) for use with a compatible fixed part and incorporates four auxiliary contacts with circuit-breaker open/closed position indication.
With a rated operational current of 1000 A, rated operational voltage of 690 V AC and rated ultimate and service short-circuit breaking capacities of up to 65 kA, the 1SDA059274R1 provides robust protection for substantial three-phase low-voltage distribution circuits.
Air circuit breakers protect and control high-current low-voltage distribution circuits by interrupting overload and short-circuit faults while providing switching and isolation capability. The withdrawable construction of the ABB 1SDA059274R1 allows the breaker moving part to be removed from its compatible fixed assembly, supporting inspection, servicing and replacement within maintainable switchboard installations.
The PR122/P-LSI R1000 electronic overcurrent release provides long-time protection against sustained overload conditions, short-time protection for selected short-circuit conditions and instantaneous protection against severe faults. Combined with the E2N platform's short-circuit performance and 1000 A current rating, the 1SDA059274R1 provides dependable protection for demanding industrial, commercial and infrastructure power distribution applications.
| Series | SACE Emax |
|---|---|
| Product group | 310513-New Emax |
| Extended product type | E2N1000PR122/P-LSIIn=1000A3pWMP |
| Order code | 1SDA059274R1 |
| Product type | Air circuit breaker moving part |
| Frame | E2N |
| Sub-type | E2 |
| Short-circuit performance level | N |
| Current type | AC |
| Rated current (In) | 1000 A |
| Rated operational current (Ie) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Rated operational voltage | 690 V AC |
| Rated voltage (Ur) | 690 V |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) | 65 kA at 220–440 V AC; 55 kA at 500–690 V AC |
| Rated service short-circuit breaking capacity (Ics) | 65 kA at 220–440 V AC; 55 kA at 500–690 V AC |
| Rated short-time withstand current (Icw) | 55 kA for 1 s; 42 kA for 3 s |
| Number of poles | 3 |
| Installation | Withdrawable |
| Component | Moving part |
| Version | W |
| Trip unit | PR122/P-LSI R1000 |
| Release type | Electronic |
| Protection functions | LSI |
| Long-time protection | L |
| Short-time protection | S |
| Instantaneous protection | I |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open/closed |
| Electrical durability | 15,000 cycles |
| Electrical operating frequency | 30 cycles per hour |
| Mechanical durability | 25,000 cycles |
| Mechanical operating frequency | 60 cycles per hour |
| Power loss | 83.2 W |
| Product net width | 324 mm |
| Product net height | 461 mm |
| Product net depth | 396.5 mm |
| Product net weight | 49 kg |
| EAN | 8015644616359 |
| Customs tariff number | 85362090 |
| Standards | IEC |
The ABB 1SDA059274R1 is a SACE Emax E2N air circuit breaker moving part used for switching and protecting high-current low-voltage electrical distribution circuits.
The 1SDA059274R1 has a rated current of 1000 A and a rated operational voltage of 690 V AC, with a rated insulation voltage of 1000 V.
The breaker is fitted with an ABB PR122/P-LSI R1000 electronic overcurrent release, providing long-time, short-time and instantaneous protection functions.
The E2N breaker has rated ultimate and service short-circuit breaking capacities of 65 kA at 220–440 V AC and 55 kA at 500–690 V AC.
The 1SDA059274R1 is a three-pole withdrawable moving part designed for use with the corresponding compatible ABB SACE Emax fixed part, allowing the breaker to be removed for inspection, servicing or replacement.
ABB SACE Emax air circuit breakers combine high-current switching, electronic protection and serviceable withdrawable construction, supporting dependable circuit protection and control across industrial, commercial and infrastructure low-voltage power distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.