1SDA059212R1 ABB E1B/MS 1000A 4-Pole Withdrawable Switch Disconnector Moving Part

1SDA059212R1 ABB E1B/MS 1000A 4-Pole Withdrawable Switch Disconnector Moving Part

ABB 1SDA059212R1 SACE Emax E1B/MS 1000 A four-pole withdrawable switch-disconnector moving part designed for high-current switching and isolation in low-voltage power distribution systems.

SKU: 1SDA059212R1MPN: 1SDA059212R1
Price
List Price £11,138.47 ex VAT
Your Price (ex VAT) Save 25%
£8,353.85 25% OFF
You save £2,784.62 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,353.85
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,353.85

Why Choose the ABB 1SDA059212R1 E1B/MS 1000 Switch Disconnector?

The ABB 1SDA059212R1 is a SACE Emax E1B/MS 1000 switch-disconnector moving part designed for high-current switching and isolation in low-voltage electrical distribution systems. Rated at 1000 A, this four-pole unit combines ABB's E1 frame with a withdrawable configuration for integration into compatible SACE Emax switchgear.

As part of the ABB SACE Emax platform, the E1B/MS is a switch-disconnector rather than a conventional overcurrent-protection circuit breaker. The 1SDA059212R1 is supplied as the withdrawable moving part (W MP), allowing it to be inserted into and removed from the corresponding compatible fixed part for servicing, inspection and switchboard maintenance.

With a rated uninterrupted current of 1000 A, rated operational voltage up to 690 V AC and 250 V DC, and a four-pole configuration, the 1SDA059212R1 provides a robust isolation solution for substantial industrial and commercial low-voltage distribution systems.

Key Advantages

  • 1000 A rated current for high-current low-voltage distribution systems.
  • Four-pole configuration for applications requiring switching and isolation across four conductors.
  • Withdrawable moving-part construction supports inspection, servicing and switchboard maintenance.
  • Purpose-designed switch-disconnector for switching and electrical isolation applications.
  • 690 V AC and 250 V DC rated operational voltage provides application flexibility.
  • 42 kA short-time withstand current for 1 s for demanding switchgear installations.
  • Part of the established ABB SACE Emax E1B/MS platform.
  • Designed for integration with the corresponding ABB SACE Emax withdrawable switchgear assembly.

Key Features

  • ABB SACE Emax E1B/MS 1000 switch disconnector.
  • 1000 A rated current (In).
  • Four-pole construction.
  • Withdrawable version.
  • Supplied as the moving part (MP).
  • 690 V AC rated operational voltage.
  • 250 V DC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 42 kA rated short-time withstand current for 1 s.
  • Mechanical durability of 25,000 cycles.
  • Designed in accordance with applicable IEC requirements.

High-Current Switching and Isolation with SACE Emax

Switch disconnectors provide switching and isolation functions within electrical distribution systems, allowing circuits or sections of an installation to be disconnected when required. Unlike an air circuit breaker fitted with an electronic overcurrent release, the E1B/MS configuration is intended primarily as a switch-disconnector and should be applied with the appropriate upstream or system protection required by the installation.

The ABB SACE Emax E1B/MS platform combines this isolation function with a high-current withdrawable design. The 1000 A rating, four-pole construction and short-time withstand capability of the 1SDA059212R1 make it suitable for demanding distribution switchboards, while the removable moving-part arrangement supports maintainability within compatible SACE Emax assemblies.

Typical Applications

  • Main low-voltage distribution switchboards.
  • High-current electrical isolation applications.
  • Industrial power distribution systems.
  • Manufacturing and process plant switchgear.
  • Commercial and infrastructure electrical distribution.
  • Busbar and distribution section isolation.
  • Withdrawable low-voltage switchgear installations.
  • OEM switchboard and power distribution assemblies.

Technical Specifications

Series SACE Emax
Product group 310513-New Emax
Extended product type E1B/MS10004pWMPnew
Order code 1SDA059212R1
Product name Switch Disconnector
Product type Air Circuit Breaker
Frame E1
Performance level B
Current type AC
Rated current (In) 1000 A
Rated operational current (Ie) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage 690 V AC / 250 V DC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated short-time withstand current (Icw) 42 kA for 1 s; 36 kA for 3 s
Number of poles 4
Installation Withdrawable
Component Moving part
Version W
Electrical durability 10,000 cycles
Electrical operating frequency 30 cycles per hour
Mechanical durability 25,000 cycles
Mechanical operating frequency 60 cycles per hour
Power loss 147.2 W
Product net width 414 mm
Product net height 461 mm
Product net depth 396.5 mm
Product net weight 54 kg
EAN 8015644615734
Customs tariff number 85362090
Standards IEC

Frequently Asked Questions

What is the ABB 1SDA059212R1 used for?

The ABB 1SDA059212R1 is a SACE Emax E1B/MS switch-disconnector moving part designed for high-current switching and isolation within compatible low-voltage electrical distribution systems.

What current rating does the ABB 1SDA059212R1 have?

The 1SDA059212R1 has a rated current of 1000 A, including a rated operational current and rated uninterrupted current of 1000 A.

How many poles does the ABB 1SDA059212R1 have?

The 1SDA059212R1 has a four-pole configuration for applications requiring four-pole switching and isolation.

Is the ABB 1SDA059212R1 fixed or withdrawable?

The 1SDA059212R1 is a withdrawable moving part designed for installation with the corresponding compatible ABB SACE Emax fixed part.

What is the short-time withstand rating of the ABB 1SDA059212R1?

The 1SDA059212R1 has a rated short-time withstand current (Icw) of 42 kA for 1 s and 36 kA for 3 s.