1SDA059186R1 ABB E1B 1000A 3-Pole Withdrawable Air Circuit Breaker Moving Part PR122/P-LSI

1SDA059186R1 ABB E1B 1000A 3-Pole Withdrawable Air Circuit Breaker Moving Part PR122/P-LSI

ABB 1SDA059186R1 SACE Emax E1B 1000 A three-pole withdrawable air circuit breaker moving part with PR122/P-LSI electronic protection and four auxiliary contacts for low-voltage power distribution systems.

SKU: 1SDA059186R1MPN: 1SDA059186R1
Price
List Price £10,804.38 ex VAT
Your Price (ex VAT) Save 25%
£8,103.29 25% OFF
You save £2,701.10 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,103.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,103.29

Why Choose the ABB 1SDA059186R1 E1B 1000 PR122/P-LSI Air Circuit Breaker?

The ABB 1SDA059186R1 is a SACE Emax E1B 1000 air circuit breaker moving part designed for protection and switching in demanding low-voltage power distribution systems. Rated at 1000 A, this three-pole withdrawable breaker is equipped with an ABB PR122/P-LSI electronic overcurrent release for comprehensive circuit protection.

As part of the ABB SACE Emax range, the E1B 1000 provides high-current switching and protection for industrial, commercial and infrastructure switchboards. The 1SDA059186R1 is supplied as the withdrawable moving part and includes four auxiliary contacts for circuit-breaker open/closed position signalling.

The integrated PR122/P-LSI release provides long-time, short-time and instantaneous protection functions. With a rated operational current of 1000 A, rated operational voltage of 690 V AC and three-pole construction, the 1SDA059186R1 provides dependable protection for substantial low-voltage distribution circuits.

Key Advantages

  • 1000 A rated current for substantial low-voltage distribution loads.
  • PR122/P-LSI electronic overcurrent release provides long-time, short-time and instantaneous protection.
  • Three-pole configuration for three-phase electrical distribution systems.
  • Withdrawable moving-part construction supports inspection, maintenance and breaker replacement.
  • Four auxiliary contacts provide circuit-breaker open/closed position signalling.
  • 42 kA ultimate and service breaking capacity across the specified 220–690 V AC range.
  • Part of the established ABB SACE Emax E1B air circuit breaker platform.
  • Designed for demanding industrial and commercial power distribution systems.

Key Features

  • ABB SACE Emax E1B 1000 air circuit breaker moving part.
  • 1000 A rated current (In).
  • Three-pole construction.
  • Withdrawable version.
  • Electronic PR122/P-LSI overcurrent release.
  • LSI protection functions: long-time, short-time and instantaneous.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 42 kA rated ultimate and service short-circuit breaking capacity.
  • Four auxiliary contacts for open/closed breaker position indication.
  • Designed in accordance with applicable IEC requirements.

Advanced Electronic Protection for Low-Voltage Distribution

Air circuit breakers protect and control high-current low-voltage distribution circuits by interrupting overload and short-circuit faults while providing a means of circuit switching and isolation. A withdrawable breaker configuration allows the moving part to be removed from its compatible fixed assembly, supporting inspection, servicing and replacement within maintainable switchboard installations.

The PR122/P-LSI electronic release fitted to the ABB 1SDA059186R1 provides long-time protection against sustained overloads, short-time protection for selected short-circuit conditions and instantaneous protection against severe faults. Combined with the E1B platform's 42 kA breaking capacity and 1000 A current rating, it provides a capable protection solution for demanding power distribution applications.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • High-current feeder protection.
  • Transformer and installation protection.
  • Manufacturing and process plant switchgear.
  • Commercial building electrical distribution.
  • Infrastructure and utility distribution assemblies.
  • Withdrawable low-voltage switchgear installations.

Technical Specifications

Series SACE Emax
Product group 310513-New Emax
Extended product type E1B1000PR122/P-LSIIn=1000A3pWMP
Order code 1SDA059186R1
Product type Air circuit breaker moving part
Frame E1B
Short-circuit performance level B
Current type AC
Rated current (In) 1000 A
Rated operational current (Ie) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) 42 kA at 220–690 V AC
Rated service short-circuit breaking capacity (Ics) 42 kA at 220–690 V AC
Rated short-time withstand current (Icw) 42 kA for 1 s; 36 kA for 3 s
Number of poles 3
Installation Withdrawable
Component Moving part
Trip unit PR122/P-LSI
Release type Electronic
Protection functions LSI
Auxiliary contacts 4
Position indication Circuit breaker open/closed
Electrical durability 10,000 cycles at Ue ≤ 440 V; 8,000 cycles at 500–690 V
Mechanical durability 25,000 cycles
Power loss 147.2 W
Product net width 324 mm
Product net height 461 mm
Product net depth 396.5 mm
Product net weight 44 kg
EAN 8015644615475
Customs tariff number 85362090
Standards IEC

Frequently Asked Questions

What is the ABB 1SDA059186R1 used for?

The ABB 1SDA059186R1 is a SACE Emax E1B air circuit breaker moving part used for switching and protecting high-current low-voltage electrical distribution circuits.

What current and voltage ratings does the ABB 1SDA059186R1 have?

The 1SDA059186R1 is rated at 1000 A with a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V and rated impulse withstand voltage of 12 kV.

What protection unit is fitted to the ABB 1SDA059186R1?

The breaker is fitted with an ABB PR122/P-LSI electronic overcurrent release providing long-time, short-time and instantaneous protection functions.

What is the breaking capacity of the ABB 1SDA059186R1?

The E1B breaker has a rated ultimate short-circuit breaking capacity (Icu) and rated service short-circuit breaking capacity (Ics) of 42 kA across the specified 220–690 V AC range.

Is the ABB 1SDA059186R1 fixed or withdrawable?

The 1SDA059186R1 is a three-pole withdrawable moving part designed for use with the corresponding compatible ABB SACE Emax fixed switchgear assembly.

Trusted ABB Power Distribution Technology

ABB SACE Emax air circuit breakers combine high-current switching, electronic protection and serviceable withdrawable construction, supporting dependable circuit protection and control across industrial, commercial and infrastructure low-voltage power distribution systems.