1SDA058311R1 ABB E2S800 PR122/P-LSIG 800A 4-Pole Withdrawable Air Circuit Breaker

1SDA058311R1 ABB E2S800 PR122/P-LSIG 800A 4-Pole Withdrawable Air Circuit Breaker

ABB E2S800 PR122/P-LSIG is an 800 A four-pole withdrawable SACE Emax air circuit breaker moving portion with LSIG electronic protection and an 85 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA058311R1MPN: 1SDA058311R1
Price
List Price £15,170.53 ex VAT
Your Price (ex VAT) Save 25%
£11,377.90 25% OFF
You save £3,792.63 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,377.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,377.90

Why Choose the ABB E2S800 PR122/P-LSIG 800A Air Circuit Breaker?

The ABB E2S800 PR122/P-LSIG is a high-performance 800 A air circuit breaker (ACB) moving portion designed for reliable protection and switching in low-voltage electrical distribution systems. As part of the proven ABB SACE Emax E2 series, this four-pole withdrawable configuration combines high short-circuit performance with the advanced PR122/P electronic trip unit for precise protection of industrial and commercial power networks.

Equipped with LSIG protection, the PR122/P trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. These functions allow the breaker to respond accurately to different fault conditions while supporting selective coordination and continuity of service within complex low-voltage distribution systems.

With a rated current of 800 A, rated operational voltage up to 690 V AC and an ultimate short-circuit breaking capacity of 85 kA at 415 V AC, the E2S800 provides robust performance for demanding power-distribution applications. This version is a four-pole withdrawable moving portion, enabling convenient installation, inspection and maintenance when used with the appropriate fixed part.

Key Advantages

  • Heavy-duty ABB SACE Emax air circuit breaker moving portion for low-voltage power distribution.
  • 800 A rated current for demanding industrial and commercial installations.
  • 85 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Advanced PR122/P electronic trip unit with LSIG protection.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Four-pole withdrawable configuration for maintainable switchgear installations.
  • 65 kA short-time withstand current for 1 s supports selective protection.
  • Fitted with auxiliary contacts and open/closed position indication for monitoring and control.

Key Features

  • ABB SACE Emax E2S 800 air circuit breaker moving portion.
  • 800 A rated uninterrupted current.
  • PR122/P-LSIG R800 electronic overcurrent release.
  • LSIG protection: long-time, short-time, instantaneous and ground fault.
  • Four-pole construction.
  • Withdrawable (W) moving portion configuration.
  • 690 V AC rated operational voltage.
  • 85 kA Icu and Ics at 415 V AC.
  • 65 kA Icw for 1 s.
  • 12 kV rated impulse withstand voltage.
  • Four auxiliary contacts and open/closed position indication.

Reliable Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB E2S800 protect electrical distribution equipment against overloads, short circuits and ground faults while providing controlled switching and isolation. The E2S performance level is engineered for systems with high prospective fault currents, making this breaker suitable for important incoming, feeder and distribution circuits.

The PR122/P electronic trip unit enhances protection flexibility through long-time, short-time, instantaneous and ground-fault functions. Combined with the withdrawable design, this configuration supports selective protection, convenient maintenance and dependable continuity of service in sophisticated low-voltage switchgear systems.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical installations.
  • Withdrawable switchgear and power distribution centres.
  • Transformer secondary and feeder protection.
  • Generator and utility distribution systems.
  • High-current machinery and plant distribution circuits.

Technical Specifications

Series SACE Emax E2
ABB order code 1SDA058311R1
Product type Air circuit breaker moving portion
Frame / breaker size E2S 800
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Rated operational current (Ie) 800 A
Trip unit PR122/P-LSIG R800
Release type Electronic
Protection functions LSIG (long-time, short-time, instantaneous and ground fault)
Number of poles 4
Version Withdrawable (W) moving portion
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 85 kA
Ultimate breaking capacity at 690 V AC 65 kA
Rated short-time withstand current (Icw) 65 kA for 1 s / 50 kA for 3 s
Power loss 53 W
Electrical durability 15,000 cycles
Mechanical durability 25,000 cycles
Dimensions (W × H × D) 414 × 461 × 396.5 mm
Net weight approx. 61 kg
EAN 8015644605995
HS code 85362090
Standard IEC
ABB product group 310513-New Emax

Frequently Asked Questions

What is the ABB E2S800 PR122/P-LSIG 1SDA058311R1 used for?

This air circuit breaker moving portion is used for switching and protecting high-current low-voltage electrical distribution circuits in industrial, commercial and infrastructure switchgear systems.

What is the current rating of the ABB 1SDA058311R1?

The E2S800 has a rated current of 800 A and is fitted with a PR122/P-LSIG R800 electronic overcurrent release.

What protection functions does the PR122/P-LSIG trip unit provide?

The PR122/P-LSIG provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection, commonly abbreviated as LSIG.

What is the breaking capacity of this E2S800 circuit breaker?

The E2S800 provides an ultimate short-circuit breaking capacity of 85 kA at 415 V AC and 65 kA at 690 V AC, with a rated short-time withstand current of 65 kA for 1 s.

Is the ABB 1SDA058311R1 a fixed or withdrawable breaker?

This model is a four-pole withdrawable moving portion designed for use with the corresponding SACE Emax fixed part, allowing the breaker to be withdrawn for inspection, servicing and replacement.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Emax air circuit breakers are engineered for dependable protection and switching in demanding low-voltage power distribution systems, combining high interruption performance, advanced electronic protection and service-friendly withdrawable construction.