1sda058162r1  t5h 400ul csapr221ds-ls/i 400 3 pole abb mccb

1sda058162r1 t5h 400ul csapr221ds-ls/i 400 3 pole abb mccb

ABB 1SDA058162R1 SACE Tmax T5H moulded case circuit breaker with 400 A rating, PR221DS-LS/I solid-state electronic release, three-pole fixed construction, front terminals and UL/CSA certification for industrial power distribution.

SKU: 1SDA058162R1Alt SKU: T5H 400 UL/CSA PR221DS-LS/I 400 3p F FMPN: 1SDA058162R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA058162R1 Tmax T5H UL/CSA Moulded Case Circuit Breaker?

The ABB 1SDA058162R1 is a high performance Tmax T5H UL/CSA moulded case circuit breaker (MCCB) designed to provide dependable protection for low voltage electrical distribution systems. As part of the proven ABB SACE Tmax T series, this circuit breaker is engineered for industrial, commercial and OEM applications requiring reliable overload and short circuit protection.

This model features a 400 A rated current within a 400 A frame size and is fitted with a PR221DS-LS/I solid-state electronic release. The release provides accurate electronic protection for AC applications, helping improve selectivity and maintain dependable operation across demanding electrical installations.

With a fixed three-pole construction, front terminals and UL/CSA certification, the ABB 1SDA058162R1 is ideal for switchboards, distribution panels, control systems and industrial feeder circuits requiring robust circuit protection for North American standard applications.

Key Advantages

  • High performance ABB Tmax T5H moulded case circuit breaker.
  • 400 A rated current in a 400 A frame size.
  • Three-pole fixed configuration for three-phase electrical systems.
  • PR221DS-LS/I electronic trip unit for accurate protection.
  • UL/CSA certified for North American electrical installations.
  • Front terminal connections for straightforward panel installation.

Key Features

  • ABB SACE Tmax T series.
  • Model: T5H 400 UL/CSA PR221DS-LS/I 400.
  • 400 A rated current.
  • 400 A frame size.
  • Three-pole (3P) MCCB configuration.
  • PR221DS-LS/I solid-state release.
  • Fixed version with front terminal connections.
  • Designed for UL/CSA low voltage circuit protection.

Reliable Protection for UL/CSA Power Distribution

The ABB Tmax T5H UL/CSA range is designed to protect electrical installations by detecting overload and short circuit conditions quickly and reliably. The PR221DS-LS/I solid-state release provides accurate protection characteristics, helping improve safety, selectivity and equipment availability.

The ABB 1SDA058162R1 is well suited to applications requiring dependable three-pole protection in North American electrical systems. Its fixed front terminal design, high interrupting ratings and proven ABB engineering make it a reliable choice for industrial panels, machinery and commercial low voltage distribution systems.

Typical Applications

  • Industrial power distribution systems.
  • UL/CSA switchboards and control panels.
  • Main incoming and outgoing feeders.
  • Three-phase electrical installations.
  • Commercial distribution boards.
  • OEM machinery and automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Current 300 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T
Model T5H 400 UL/CSA PR221DS-LS/I 400 3p F F
Product code 1SDA058162R1
EAN 8015644604271
Product type Moulded case circuit breaker (MCCB)
Rated current (In) 400 A
Rated uninterrupted current (Iu) 400 A
Frame size T5 400
Number of poles 3
Trip unit PR221DS-LS/I electronic release
Release type Solid-state electronic
Rated operational voltage 600 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Interrupting rating 150 kA at 240 V AC, 65 kA at 480 V AC, 35 kA at 600 V AC
Short-circuit performance level H
Terminal type Fixed front terminals
Mounting Panel mounted
Electrical durability 5,000 cycles
Mechanical durability 20,000 cycles
Standards UL / CSA
Dimensions (H × W × D) 205 × 140 × 103.5 mm
Weight Approx. 5.1 kg

Frequently Asked Questions

What is the ABB 1SDA058162R1 used for?

It is used to protect low voltage electrical distribution systems against overloads and short circuits in industrial, commercial and OEM applications.

What is the rated current of this MCCB?

The ABB 1SDA058162R1 has a rated current of 400 A.

How many poles does this circuit breaker have?

This model has a three-pole (3P) configuration, making it suitable for three-phase electrical systems.

Which trip unit is fitted?

The breaker is fitted with a PR221DS-LS/I solid-state electronic release for accurate AC circuit protection.

Is this circuit breaker UL/CSA certified?

Yes, the ABB 1SDA058162R1 is a UL/CSA version designed for installations requiring North American certification.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax moulded case circuit breakers are trusted by electrical engineers, panel builders and industrial maintenance teams worldwide for dependable circuit protection, compact installation and long-term reliability in demanding power distribution applications.