1sda058159r1  t5s 400ul csapr222ds/p-lsig 300 3 pole abb mccb

1sda058159r1 t5s 400ul csapr222ds/p-lsig 300 3 pole abb mccb

ABB 1SDA058159R1 Tmax T5S 300 A three-pole moulded case circuit breaker with PR222DS/P-LSIG electronic release, fixed front terminals and UL/CSA configuration for low voltage circuit protection.

SKU: 1SDA058159R1Alt SKU: T5S 400 UL/CSA PR222DS/P-LSIG 300 3p F FMPN: 1SDA058159R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA058159R1 Tmax T5S Moulded Case Circuit Breaker?

The ABB 1SDA058159R1 is a dependable Tmax T5S moulded case circuit breaker (MCCB) designed for low voltage electrical protection in industrial, commercial and OEM applications. Part of the trusted ABB SACE Tmax T series, this breaker provides reliable overload, short-circuit and earth fault protection for demanding power distribution systems.

This model features a PR222DS/P-LSIG solid-state electronic release, offering long-time, short-time, instantaneous and ground fault protection functions for enhanced system safety and selectivity. Its UL/CSA configuration makes it suitable for installations requiring North American approval standards, while the fixed three-pole design with front terminals supports straightforward panel and switchboard installation.

With a 300 A rated current, 400 A frame rating and 600 V AC rated operational voltage, the ABB 1SDA058159R1 is well suited to feeder protection, switchboards, motor control centres and industrial distribution systems where accurate circuit protection and robust ABB performance are required.

Key Advantages

  • Reliable ABB Tmax T5S moulded case circuit breaker for low voltage distribution.
  • 300 A rated current with a 400 A frame size.
  • PR222DS/P-LSIG electronic release with ground fault protection.
  • Three-pole fixed breaker with front terminal connections.
  • UL/CSA approved configuration for compliant installations.
  • Suitable for switchboards, MCCs, feeder circuits and OEM panels.

Key Features

  • ABB SACE Tmax T5S series.
  • Product code: 1SDA058159R1.
  • Rated current: 300 A.
  • Rated uninterrupted current: 400 A.
  • Three-pole fixed circuit breaker.
  • PR222DS/P-LSIG solid-state release.
  • 600 V AC rated operational voltage.
  • Fixed front terminal connection for switchboard installation.

Reliable Protection for Low Voltage Distribution

Moulded case circuit breakers such as the ABB Tmax T5S help protect electrical installations by disconnecting circuits during overload, short-circuit and earth fault conditions. This helps reduce damage to cables, switchgear and connected equipment while supporting safer operation across industrial distribution networks.

The PR222DS/P-LSIG electronic release provides flexible protection functions for applications requiring improved selectivity and fault control. Its fixed construction and front terminal layout make the ABB 1SDA058159R1 a practical choice for panel builders and engineers working with compact electrical assemblies.

Typical Applications

  • Industrial switchboards and control panels.
  • Commercial power distribution systems.
  • Motor control centres.
  • Feeder and sub-distribution circuit protection.
  • OEM machinery and automation systems.
  • Installations requiring UL/CSA compliant MCCB protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 300 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T5S
Model 1SDA058159R1
Extended product type T5S 400 UL/CSA PR222DS/P-LSIG 300 3p F F
Product type Moulded case circuit breaker
Frame size T5
Rated current (In) 300 A
Rated uninterrupted current (Iu) 400 A
Number of poles 3P
Release PR222DS/P-LSIG
Release type Electronic
Rated operational voltage 600 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Terminal connection Fixed front terminals
Mechanical durability 20,000 cycles
Power loss 9.3 W per pole at rated operating conditions
EAN 8015644604240
Standards UL / CSA
Dimensions (H × W × D) approx. 205 × 140 × 103.5 mm
Weight approx. 5.1 kg

Frequently Asked Questions

What is the ABB 1SDA058159R1 used for?

The ABB 1SDA058159R1 is used to protect low voltage electrical distribution systems from overloads, short circuits and earth fault conditions.

What is the rated current of this breaker?

This model has a 300 A rated current and is built on a 400 A Tmax T5 frame.

What trip unit is fitted to the ABB 1SDA058159R1?

It is fitted with a PR222DS/P-LSIG solid-state electronic release, providing long-time, short-time, instantaneous and ground fault protection functions.

How many poles does this circuit breaker have?

The ABB 1SDA058159R1 is a three-pole fixed circuit breaker with front terminal connections.

Is the ABB 1SDA058159R1 suitable for UL/CSA installations?

Yes, this version is designed for UL/CSA applications, making it suitable for installations where those approval standards are required.

Trusted by Electrical Professionals Worldwide

ABB Tmax moulded case circuit breakers are widely used by panel builders, electrical contractors and industrial engineers for reliable low voltage circuit protection, durable construction and trusted performance in demanding installations.