1sda058156r1  t5s 400ul csapr221ds-ls/i 300 3 pole abb mccb

1sda058156r1 t5s 400ul csapr221ds-ls/i 300 3 pole abb mccb

ABB 1SDA058156R1 Tmax T5S 300 A three-pole moulded case circuit breaker with PR221DS-LS/I electronic release, fixed front terminals and UL/CSA configuration for low voltage circuit protection.

SKU: 1SDA058156R1Alt SKU: T5S 400 UL/CSA PR221DS-LS/I 300 3p F FMPN: 1SDA058156R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA058156R1 Tmax T5S Moulded Case Circuit Breaker?

The ABB 1SDA058156R1 is a dependable Tmax T5S moulded case circuit breaker (MCCB) designed for low voltage electrical protection in industrial, commercial and OEM applications. Part of the established ABB SACE Tmax T series, this breaker provides reliable overload and short-circuit protection for switchboards, distribution panels and machinery control systems.

This model features a PR221DS-LS/I solid-state electronic release, providing long-time, short-time and instantaneous protection functions for accurate fault response. Its UL/CSA configuration makes it suitable for installations requiring North American approval standards, while the fixed three-pole format with front terminals supports straightforward panel integration.

With a 300 A rated current, 400 A frame rating and 600 V AC rated operational voltage, the ABB 1SDA058156R1 is ideal for demanding power distribution applications where consistent electrical protection, robust construction and trusted ABB performance are required.

Key Advantages

  • Reliable ABB Tmax T5S moulded case circuit breaker for industrial distribution.
  • 300 A rated current with a 400 A frame size.
  • PR221DS-LS/I electronic release for accurate circuit protection.
  • Three-pole fixed breaker with front terminal connections.
  • UL/CSA approved configuration for compliant installations.
  • Suitable for switchboards, distribution panels, machinery and OEM systems.

Key Features

  • ABB SACE Tmax T5S series.
  • Product code: 1SDA058156R1.
  • Rated current: 300 A.
  • Rated uninterrupted current: 400 A.
  • Three-pole fixed circuit breaker.
  • PR221DS-LS/I solid-state release.
  • 600 V AC rated operational voltage.
  • Fixed front terminal connection for switchboard installation.

Reliable Protection for Low Voltage Distribution

Moulded case circuit breakers such as the ABB Tmax T5S help protect electrical installations by disconnecting circuits during overload or short-circuit conditions. This reduces the risk of damage to cables, switchgear and connected equipment while supporting safer operation across electrical distribution networks.

The PR221DS-LS/I electronic trip unit provides dependable protection performance for feeder circuits, panel boards and industrial machinery. Its compact fixed construction and front terminal arrangement make the ABB 1SDA058156R1 a practical choice for panel builders and engineers working with space-conscious electrical assemblies.

Typical Applications

  • Industrial switchboards and control panels.
  • Commercial power distribution systems.
  • Motor control centres.
  • OEM machinery and automation systems.
  • Feeder and sub-distribution circuit protection.
  • Installations requiring UL/CSA compliant MCCB protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 300 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Electronic
Manufacturer ABB
Series SACE Tmax T5S
Model 1SDA058156R1
Extended product type T5S 400 UL/CSA PR221DS-LS/I 300 3p F F
Product type Moulded case circuit breaker
Frame size T5
Rated current (In) 300 A
Rated uninterrupted current (Iu) 400 A
Number of poles 3P
Release PR221DS-LS/I
Release type Electronic
Rated operational voltage 600 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Terminal connection Fixed front terminals
Mechanical durability 20,000 cycles
Power loss 9.3 W per pole at rated operating conditions
Standards UL / CSA
Dimensions (H × W × D) approx. 205 × 140 × 103.5 mm
Weight approx. 5.1 kg

Frequently Asked Questions

What is the ABB 1SDA058156R1 used for?

The ABB 1SDA058156R1 is used to protect low voltage electrical distribution systems from overloads and short circuits.

What is the rated current of this breaker?

This model has a 300 A rated current and is built on a 400 A Tmax T5 frame.

What trip unit is fitted to the ABB 1SDA058156R1?

It is fitted with a PR221DS-LS/I solid-state electronic release for long-time, short-time and instantaneous protection functions.

How many poles does this circuit breaker have?

The ABB 1SDA058156R1 is a three-pole fixed circuit breaker with front terminal connections.

Is the ABB 1SDA058156R1 suitable for UL/CSA installations?

Yes, this version is designed for UL/CSA applications, making it suitable for installations where those approval standards are required.

Trusted by Electrical Professionals Worldwide

ABB Tmax moulded case circuit breakers are widely used by panel builders, electrical contractors and industrial engineers for reliable low voltage circuit protection, durable construction and trusted performance in demanding installations.