1SDA058138R1 ABB T4L 250 UL/CSA TMA 150A 3P Moulded-Case Circuit Breaker

1SDA058138R1 ABB T4L 250 UL/CSA TMA 150A 3P Moulded-Case Circuit Breaker

ABB 1SDA058138R1 is a three-pole Tmax T4L 250 UL/CSA moulded-case circuit breaker with a 150 A TMA thermomagnetic trip unit and adjustable 750–1500 A magnetic short-circuit protection.

SKU: 1SDA058138R1Alt SKU: T4L250UL/CSATMA150MPN: 1SDA058138R1
Price
List Price £2,289.44 ex VAT
Your Price (ex VAT) Save 25%
£1,717.08 25% OFF
You save £572.36 per unit
Manufacturer Lead Time Estimated Delivery 4 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,717.08
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,717.08

Why Choose the ABB T4L 250 1SDA058138R1 Moulded-Case Circuit Breaker?

The ABB 1SDA058138R1 is a Tmax T4L 250 three-pole moulded-case circuit breaker (MCCB) designed for reliable protection of low-voltage industrial and commercial electrical distribution systems. As part of the ABB Tmax T4–T8 range, this breaker combines the T4 250 frame with a TMA thermomagnetic trip unit and is designed for applications requiring UL/CSA-compliant circuit protection.

The breaker incorporates a TMA adjustable thermomagnetic trip unit, providing thermal overload protection together with magnetic short-circuit protection. Its overload setting is based around a 150 A rating, while the instantaneous magnetic protection is adjustable from 750–1500 A, enabling protection to be coordinated with the requirements of the connected circuit.

The T4L 250 is supplied in a three-pole fixed configuration and is intended for three-phase distribution applications. Its high-performance L breaking-capacity version, adjustable protection and established ABB Tmax construction make the 1SDA058138R1 suitable for switchboards, distribution panels, machinery supplies and industrial feeder protection.

Key Advantages

  • Genuine ABB Tmax T4L 250 moulded-case circuit breaker.
  • 150 A TMA thermomagnetic protection for low-voltage distribution circuits.
  • Adjustable 750–1500 A instantaneous magnetic protection.
  • Three-pole configuration for three-phase electrical systems.
  • High-performance T4L breaking-capacity version.
  • Designed for UL/CSA applications and industrial power distribution.

Key Features

  • ABB Tmax T4L 250 circuit-breaker platform.
  • TMA adjustable thermomagnetic trip unit.
  • 150 A nominal trip-unit rating.
  • 750–1500 A magnetic trip adjustment range.
  • Three-pole (3P) construction.
  • Fixed circuit-breaker configuration.
  • Thermal overload and magnetic short-circuit protection.
  • UL/CSA version for North American industrial applications.

Reliable Thermomagnetic Protection for Power Distribution

Moulded-case circuit breakers protect electrical conductors and connected equipment against potentially damaging overcurrents. The TMA trip unit in the ABB T4L 250 combines a thermal protection element for sustained overload conditions with an adjustable magnetic element that provides rapid operation during high-current short circuits.

For the 1SDA058138R1, the magnetic protection range of 750–1500 A allows the instantaneous trip threshold to be selected to suit the application. Combined with the robust Tmax T4 platform and three-pole construction, this makes the breaker a practical solution for protecting three-phase feeders, machinery circuits and industrial distribution equipment.

Typical Applications

  • Industrial low-voltage power distribution.
  • Three-phase feeder protection.
  • Industrial machinery and equipment supplies.
  • Main and sub-distribution switchboards.
  • Commercial and industrial distribution panels.
  • UL/CSA electrical installations requiring adjustable thermomagnetic protection.

Technical Specifications

Series Tmax T4–T8
Order code 1SDA058138R1
Product type Moulded-case circuit breaker (MCCB)
Frame T4
Frame size 250 A
Breaking-capacity version L
Trip unit TMA thermomagnetic
Trip-unit rating 150 A
Magnetic protection setting 750–1500 A
Number of poles 3
Mounting / execution Fixed
Protection functions Thermal overload and magnetic short circuit
Certification version UL/CSA
ABB product group 310511-T-Max T4 - T8

Frequently Asked Questions

What is the ABB 1SDA058138R1 used for?

The ABB 1SDA058138R1 is a three-pole Tmax T4L 250 moulded-case circuit breaker used to provide overload and short-circuit protection in low-voltage electrical distribution systems.

What trip unit does the ABB 1SDA058138R1 use?

The breaker uses an ABB TMA adjustable thermomagnetic trip unit, combining thermal overload protection with magnetic short-circuit protection.

What is the current rating of the ABB 1SDA058138R1?

The TMA trip unit is rated at 150 A and is installed within the T4L 250 circuit-breaker platform.

What is the magnetic trip range of the ABB 1SDA058138R1?

The instantaneous magnetic protection is adjustable over a range of 750–1500 A, allowing the short-circuit trip threshold to be coordinated with the protected circuit.

How many poles does the ABB 1SDA058138R1 have?

The 1SDA058138R1 is a three-pole (3P) circuit breaker designed for applications including three-phase low-voltage distribution systems.

Trusted ABB Circuit Protection

ABB Tmax moulded-case circuit breakers provide dependable overload and short-circuit protection for industrial and commercial electrical distribution systems, combining robust breaker construction with coordinated trip-unit technology and a comprehensive range of installation accessories.