1SDA057867R1 ABB E4S-A 3600 PR122/P-LSIG 3600 A 3-Pole Fixed Air Circuit Breaker

1SDA057867R1 ABB E4S-A 3600 PR122/P-LSIG 3600 A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA057867R1 is a SACE Emax E4S-A 3600 A three-pole fixed air circuit breaker with rear horizontal terminals and a PR122/P-LSIG R3600 electronic overcurrent release providing long-time, short-time, instantaneous and ground-fault protection.

SKU: 1SDA057867R1MPN: 1SDA057867R1
Price
List Price £32,210.05 ex VAT
Your Price (ex VAT) Save 25%
£24,157.54 25% OFF
You save £8,052.51 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £24,157.54
Trade pricing is personalised to your account

Manufacturer Lead Time

£24,157.54

Why Choose the ABB E4S-A 3600 PR122/P-LSIG Air Circuit Breaker?

The ABB E4S-A 3600 PR122/P-LSIG, order code 1SDA057867R1, is a high-performance SACE Emax air circuit breaker designed for demanding low-voltage power distribution systems. This three-pole fixed breaker combines the E4S-A platform with a PR122/P-LSIG R3600 electronic overcurrent release, providing comprehensive protection for critical high-current electrical circuits.

Rated at 3600 A, the breaker provides LSIG protection comprising long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault functions. Its electronic protection capabilities support coordinated fault management in industrial, commercial and infrastructure distribution networks where dependable protection and continuity of electrical service are important.

The 1SDA057867R1 is a three-pole fixed version with rear horizontal terminals. Its configuration also includes four auxiliary contacts and open/closed position indication, providing useful breaker status information for integration with switchboard signalling, monitoring and control systems.

Key Advantages

  • High-current 3600 A SACE Emax air circuit breaker.
  • PR122/P-LSIG R3600 electronic overcurrent release for comprehensive protection.
  • LSIG functionality provides long-time, short-time, instantaneous and ground-fault protection.
  • Three-pole fixed configuration for three-phase power distribution.
  • Rear horizontal terminals for fixed switchboard installation.
  • Four auxiliary contacts support breaker status signalling and control integration.
  • ABB E4S-A platform designed for demanding high-current distribution duties.

Key Features

  • ABB SACE Emax E4S-A circuit breaker platform.
  • 3600 A rated current.
  • Three-pole construction.
  • Fixed breaker execution.
  • Rear horizontal terminals.
  • PR122/P-LSIG R3600 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • Four auxiliary contacts with open/closed position indication.

Advanced LSIG Protection for High-Current Distribution

Air circuit breakers such as the ABB SACE Emax E4S-A provide switching, isolation and fault protection within high-current low-voltage distribution systems. Electronic trip technology monitors circuit conditions and initiates breaker operation when configured protection thresholds are exceeded, helping protect switchgear, conductors and connected electrical equipment.

The PR122/P-LSIG release combines long-time overload protection, short-time protection for selective coordination, instantaneous protection against severe short circuits and ground-fault protection. This comprehensive protection arrangement makes the E4S-A 3600 suitable for main distribution circuits and high-current feeders where reliable and coordinated electrical protection is required.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main incoming electrical distribution circuits.
  • High-current distribution feeders.
  • Manufacturing and process plants.
  • Commercial and infrastructure power systems.
  • Transformer and generator distribution systems.

Technical Specifications

Series SACE Emax / New Emax
ABB order code 1SDA057867R1
Product group 310513-New Emax
Product type Air circuit breaker
Frame E4S-A
Rated current 3600 A
Number of poles 3
Trip unit PR122/P-LSIG R3600
Protection functions Long-time, short-time, instantaneous and ground fault (LSIG)
Execution Fixed
Terminals Rear horizontal
Auxiliary contacts 4
Position indication Open / closed
Version UL
Weight 81 kg
EAN 8015644601300

Frequently Asked Questions

What is the ABB 1SDA057867R1?

The ABB 1SDA057867R1 is a SACE Emax E4S-A three-pole fixed air circuit breaker rated at 3600 A and fitted with a PR122/P-LSIG R3600 electronic overcurrent release.

What protection does the PR122/P-LSIG release provide?

The PR122/P-LSIG provides long-time, short-time, instantaneous and ground-fault protection, collectively identified as LSIG protection.

What is the rated current of the ABB E4S-A 3600?

The ABB 1SDA057867R1 has a rated current of 3600 A, making it suitable for demanding high-current low-voltage distribution applications.

Is the ABB 1SDA057867R1 fixed or withdrawable?

The 1SDA057867R1 is a fixed three-pole air circuit breaker with rear horizontal terminals for installation within a suitable low-voltage switchboard.

What auxiliary signalling is included?

The breaker is fitted with four auxiliary contacts and open/closed position indication, supporting integration with switchboard signalling, monitoring and control systems.

Trusted Protection from ABB

ABB SACE Emax air circuit breakers combine robust high-current switching, advanced electronic protection and practical switchboard integration for demanding industrial, commercial and infrastructure low-voltage power distribution systems.