ABB 1SDA057863R1 E4S-A 3600 PR122/P-LSI is a 3600 A three-pole fixed SACE Emax air circuit breaker with horizontal rear terminals and PR122/P electronic LSI overcurrent protection for demanding low-voltage power distribution systems.
£23,298.02
The ABB E4S-A 3600 PR122/P-LSI, order code 1SDA057863R1, is a high-performance SACE Emax air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. As part of the advanced ABB SACE Emax E4S series, this three-pole fixed breaker combines a 3600 A current rating with the PR122/P electronic overcurrent release.
The breaker is equipped with LSI protection, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection. The PR122/P electronic trip unit enables accurate protection and coordination of high-current distribution circuits, helping safeguard cables, busbars and connected electrical equipment.
With a rated current of 3600 A, a three-pole fixed configuration and horizontal rear terminals, the E4S-A 3600 PR122/P-LSI is well suited to main switchboards, industrial distribution assemblies and other critical low-voltage installations. The E4S-A 3600 platform provides a short-circuit breaking capacity of 65 kA at 480 V AC and a short-time withstand current of 65 kA.
Air circuit breakers such as the ABB SACE Emax E4S protect electrical distribution systems against overload and short-circuit conditions while providing dependable switching of high-current circuits. Their robust construction makes them particularly suitable for main distribution boards, industrial switchgear and other installations where continuity and electrical protection are critical.
The PR122/P electronic release provides advanced protection within the Emax platform. In this LSI configuration, the trip unit provides long-time protection against sustained overloads, short-time protection for coordinated short-circuit protection and instantaneous operation against severe fault currents.
| Series | SACE Emax E4S-A |
|---|---|
| ABB order code | 1SDA057863R1 |
| EAN | 8015644601263 |
| Product type | Air circuit breaker |
| Frame size | E4 |
| Rated current | 3600 A |
| Number of poles | 3 |
| Trip unit | PR122/P |
| Protection functions | LSI (long-time, short-time and instantaneous) |
| Short-circuit breaking capacity at 480 V AC | 65 kA |
| Short-time withstand current | 65 kA |
| Execution | Fixed |
| Terminal arrangement | Horizontal rear terminals |
| Auxiliary contacts | 4 |
| Net weight | 81 kg |
| Application | Low-voltage power distribution and circuit protection |
| ABB product group | 310513-New Emax |
The ABB 1SDA057863R1 is a SACE Emax E4S-A 3600 three-pole fixed air circuit breaker rated at 3600 A and equipped with a PR122/P-LSI electronic overcurrent release.
The E4S-A 3600 PR122/P-LSI has a rated current of 3600 A.
The LSI configuration provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.
This version is a fixed air circuit breaker equipped with horizontal rear terminals for integration into compatible low-voltage switchgear.
It is typically used in high-current low-voltage switchboards, industrial power distribution systems, manufacturing facilities and other installations requiring dependable overload and short-circuit protection.
ABB SACE Emax air circuit breakers are engineered for dependable protection and switching in demanding low-voltage power distribution systems, combining robust breaker technology with advanced electronic protection.