1SDA057759R1 ABB E3V-A 2000 PR121/P-LSIG 2000 A 3-Pole Air Circuit Breaker

1SDA057759R1 ABB E3V-A 2000 PR121/P-LSIG 2000 A 3-Pole Air Circuit Breaker

ABB 1SDA057759R1 is a SACE New Emax E3V-A three-pole air circuit breaker rated at 2000 A and equipped with a PR121/P-LSIG electronic overcurrent release for long-time, short-time, instantaneous and ground-fault protection.

SKU: 1SDA057759R1MPN: 1SDA057759R1
Price
List Price £17,425.76 ex VAT
Your Price (ex VAT) Save 25%
£13,069.32 25% OFF
You save £4,356.44 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £13,069.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£13,069.32

Why Choose the ABB E3V-A 2000 PR121/P-LSIG 1SDA057759R1 Air Circuit Breaker?

The ABB E3V-A 2000 PR121/P-LSIG, order code 1SDA057759R1, is a high-performance three-pole air circuit breaker (ACB) from the ABB SACE New Emax range, designed for protection and switching in demanding low-voltage electrical distribution systems. Rated at 2000 A, this E3V-A configuration combines robust Emax circuit breaker technology with the PR121/P-LSIG electronic overcurrent release.

The PR121/P-LSIG trip unit provides long-time, short-time, instantaneous and ground-fault protection, helping protect electrical installations, conductors and connected equipment against overloads, short circuits and earth faults. These LSIG protection functions provide comprehensive electronic protection for industrial and commercial distribution networks where effective fault management and protection coordination are required.

With a rated current of 2000 A and a three-pole configuration, the 1SDA057759R1 is designed for high-current three-phase power distribution. The E3V-A platform is intended for demanding low-voltage switchgear applications where high-performance circuit protection, dependable switching and electronic fault protection are essential.

Key Advantages

  • High-performance ABB SACE New Emax air circuit breaker for demanding low-voltage distribution.
  • 2000 A rated current for high-current industrial and commercial applications.
  • Three-pole configuration for three-phase electrical distribution systems.
  • PR121/P-LSIG electronic overcurrent release for comprehensive circuit protection.
  • LSIG functions provide long-time, short-time, instantaneous and ground-fault protection.
  • Electronic protection supports selective coordination and effective fault management.
  • Robust E3V-A construction for integration into compatible ABB SACE New Emax switchgear.

Key Features

  • ABB SACE New Emax E3V-A circuit breaker platform.
  • 2000 A rated current.
  • Three-pole configuration.
  • PR121/P-LSIG electronic trip unit.
  • 2000 A release rating.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • Electronic overcurrent protection for demanding distribution systems.
  • Designed for high-current low-voltage power distribution and switchgear applications.

Reliable Circuit Protection for Power Distribution

Air circuit breakers such as the ABB SACE New Emax E3V-A are designed to protect high-current low-voltage electrical distribution systems against overload, short-circuit and ground-fault conditions. The electronic trip unit monitors circuit current and initiates breaker operation when configured protection thresholds are exceeded, helping safeguard cables, switchgear and connected electrical equipment.

The PR121/P-LSIG electronic release provides four key protection functions covering long-time overloads, short-time faults, instantaneous short circuits and ground faults. Combined with the E3V-A breaker platform, these functions make the 1SDA057759R1 suitable for power distribution systems requiring comprehensive protection and coordinated fault management.

Typical Applications

  • Industrial low-voltage power distribution systems.
  • Main incoming and distribution switchboards.
  • Industrial plants and manufacturing facilities.
  • Commercial building electrical distribution.
  • High-current feeder and circuit protection.
  • Power distribution centres and switchgear assemblies.

Technical Specifications

Series SACE New Emax
ABB product group 310513-New Emax
Order code / MPN 1SDA057759R1
Product type Air circuit breaker
Frame E3V-A
Rated current 2000 A
Number of poles 3
Trip unit PR121/P-LSIG
Protection functions Long-time (L), short-time (S), instantaneous (I) and ground fault (G)
Release rating 2000 A
Current type AC

Frequently Asked Questions

What is the ABB 1SDA057759R1 used for?

The ABB 1SDA057759R1 is a SACE New Emax E3V-A air circuit breaker designed to protect and switch high-current low-voltage electrical distribution circuits in industrial and commercial installations.

What is the rated current of the ABB E3V-A 1SDA057759R1?

The circuit breaker has a rated current of 2000 A.

Which trip unit is fitted to the ABB 1SDA057759R1?

The breaker is fitted with an ABB PR121/P-LSIG electronic overcurrent release.

What protection functions does the PR121/P-LSIG provide?

The PR121/P-LSIG provides long-time, short-time, instantaneous and ground-fault protection, covering overload, short-circuit and earth-fault conditions.

How many poles does the ABB 1SDA057759R1 have?

The 1SDA057759R1 has a three-pole configuration for three-phase low-voltage electrical distribution applications.

Trusted ABB Power Distribution Technology

ABB SACE New Emax air circuit breakers are engineered for dependable protection and switching in demanding low-voltage power distribution systems, combining robust breaker construction with electronic protection for industrial and commercial switchgear.