ABB 1SDA057535R1 E3S-A 2500 PR121/P-LSIG is a 2500 A three-pole SACE Emax air circuit breaker with long-time, short-time, instantaneous and earth-fault electronic protection for demanding low-voltage power distribution systems.
£13,144.01
The ABB E3S-A 2500 PR121/P-LSIG, order code 1SDA057535R1, is a high-current SACE Emax air circuit breaker designed for dependable switching and protection in demanding low-voltage power distribution systems. This E3S-A model has a rated current of 2500 A, three-pole construction and ABB's PR121/P-LSIG electronic overcurrent release.
The PR121/P-LSIG trip unit provides long-time, short-time, instantaneous and earth-fault protection. These LSIG functions help protect cables, busbars, switchgear and connected equipment against overloads, short circuits and earth faults while supporting coordinated protection throughout the electrical distribution system.
As part of the ABB SACE Emax family, the E3S-A combines robust air circuit breaker construction with electronic protection for high-current applications. Its 2500 A current rating and three-pole configuration make it suitable for substantial three-phase distribution circuits such as main incomers, high-current feeders and bus-coupler positions.
Air circuit breakers such as the ABB SACE Emax E3S-A provide controlled switching and protection for high-current low-voltage distribution circuits. The electronic trip unit monitors circuit conditions and initiates tripping when configured protection thresholds are exceeded, helping limit damage caused by overloads, short circuits and earth faults.
The PR121/P-LSIG release combines four key protection functions in one electronic trip unit. Together with the robust E3S-A platform, this makes 1SDA057535R1 suitable for important distribution points where dependable fault interruption, protection coordination and continuity of electrical service are required.
| Series | SACE Emax |
|---|---|
| ABB order code | 1SDA057535R1 |
| Product group | 310513-New Emax |
| Product type | Air circuit breaker |
| Frame | E3 |
| Performance level | S-A |
| Rated current (In) | 2500 A |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | PR121/P-LSIG |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and earth-fault (LSIG) |
| Application | Low-voltage power distribution |
It is a 2500 A three-pole SACE Emax air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems.
This model is fitted with the ABB PR121/P-LSIG electronic overcurrent release, providing comprehensive LSIG circuit protection.
The ABB E3S-A circuit breaker has a rated current of 2500 A.
The 1SDA057535R1 has a three-pole configuration suitable for three-phase low-voltage electrical distribution systems.
The PR121/P-LSIG provides long-time, short-time, instantaneous and earth-fault protection, collectively identified as LSIG protection.
ABB SACE Emax air circuit breakers are engineered for dependable switching and protection in demanding low-voltage power distribution systems, combining robust construction with electronic trip technology for accurate and coordinated circuit protection.