1SDA057397R1 ABB E3N-A 2000 PR123/P-LSIG 2000A 3P Air Circuit Breaker

1SDA057397R1 ABB E3N-A 2000 PR123/P-LSIG 2000A 3P Air Circuit Breaker

ABB 1SDA057397R1 E3N-A 2000 PR123/P-LSIG is a 2000 A three-pole SACE Emax air circuit breaker with advanced long-time, short-time, instantaneous and ground-fault electronic protection for high-current low-voltage distribution systems.

SKU: 1SDA057397R1MPN: 1SDA057397R1
Price
List Price £25,624.04 ex VAT
Your Price (ex VAT) Save 25%
£19,218.03 25% OFF
You save £6,406.01 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £19,218.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£19,218.03

Why Choose the ABB E3N-A 2000 PR123/P-LSIG 2000A 3P Air Circuit Breaker?

The ABB E3N-A 2000 PR123/P-LSIG, order code 1SDA057397R1, is a high-current SACE Emax air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. Built on the ABB E3N-A platform, this three-pole breaker has a rated current of 2000 A and is intended for major industrial, commercial and infrastructure distribution circuits.

The breaker is equipped with the advanced ABB PR123/P-LSIG electronic overcurrent release. Its LSIG protection functions provide long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection, delivering comprehensive safeguarding for cables, busbars, switchgear and connected electrical equipment.

With its three-pole configuration, 2000 A rated current and N performance level, the E3N-A 2000 PR123/P-LSIG is suited to critical main incomer and high-current feeder duties. The advanced PR123/P release also provides greater protection functionality than basic LI or LSI releases, making this configuration particularly suitable where comprehensive fault protection and distribution-system coordination are required.

Key Advantages

  • High-capacity 2000 A SACE Emax air circuit breaker for major low-voltage distribution circuits.
  • Three-pole configuration for three-phase electrical systems.
  • Advanced PR123/P-LSIG electronic overcurrent release.
  • LSIG functionality provides long-time, short-time, instantaneous and ground-fault protection.
  • Ground-fault protection adds an important additional layer of protection for distribution systems.
  • N performance level for demanding power distribution applications.
  • Electronic protection supports coordinated operation within complex distribution networks.
  • Suitable for main incomers, high-current feeders and critical distribution circuits.

Key Features

  • ABB SACE Emax E3N-A air circuit breaker.
  • 2000 A rated current.
  • Three-pole (3P) configuration.
  • PR123/P-LSIG electronic protection release.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • N performance level.
  • Electronic overcurrent protection for critical high-current circuits.
  • Suitable for selective and coordinated protection strategies.
  • Designed for demanding industrial and commercial low-voltage distribution systems.

Advanced LSIG Protection for 2000A Power Distribution

The ABB SACE Emax E3N-A is designed to provide switching, isolation and electronic overcurrent protection for major low-voltage distribution circuits. Its PR123/P release continuously evaluates circuit current and provides dedicated responses to different fault conditions, helping protect electrical infrastructure against overloads, short circuits and ground faults.

The LSIG protection arrangement combines long-time protection for sustained overloads with short-time and instantaneous functions for short-circuit faults, while the ground-fault function extends protection to earth-fault conditions. This comprehensive protection package makes the E3N-A 2000 particularly suitable for high-capacity distribution networks where selectivity, equipment protection and dependable system operation are priorities.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main incomer circuit protection.
  • High-current distribution feeders.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Infrastructure electrical systems.
  • Transformer secondary distribution.
  • Power distribution centres and major switchgear assemblies.

Technical Specifications

Series SACE Emax
ABB order code 1SDA057397R1
Product group 310513-New Emax
Product type Air circuit breaker (ACB)
Frame / size E3
Performance level N
Rated current (In) 2000 A
Number of poles 3P
Trip unit PR123/P-LSIG electronic release
Protection functions Long-time (L), short-time (S), instantaneous (I), ground fault (G)
Current type AC

Frequently Asked Questions

What is the ABB 1SDA057397R1 used for?

The ABB 1SDA057397R1 is a 2000 A three-pole SACE Emax air circuit breaker designed for protection, switching and isolation of high-current low-voltage power distribution circuits.

What trip unit is fitted to the ABB E3N-A 2000?

This circuit breaker is equipped with the advanced ABB PR123/P-LSIG electronic release for comprehensive electronic overcurrent and ground-fault protection.

What protection functions does PR123/P-LSIG provide?

The PR123/P-LSIG provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.

What is the rated current of the ABB 1SDA057397R1?

The ABB E3N-A circuit breaker has a rated current of 2000 A and a three-pole configuration.

Where is the ABB E3N-A 2000 PR123/P-LSIG typically used?

This breaker is suited to main incomers, high-current feeders, industrial switchboards, transformer secondary distribution and power distribution centres requiring comprehensive LSIG electronic protection.

Trusted High-Current Protection from ABB

ABB SACE Emax air circuit breakers combine robust power switching with advanced electronic protection, providing dependable protection for critical incomers, feeders and low-voltage distribution infrastructure.