Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA057387R1 is a SACE Emax E3N-A three-pole fixed air circuit breaker rated at 2000 A and 600 V with rear horizontal terminals and a PR122/P-LSIG electronic release providing long-time, short-time, instantaneous and ground-fault protection.
£12,940.25
The ABB 1SDA057387R1 is a SACE Emax E3N-A air circuit breaker designed for protection and switching in demanding low-voltage power distribution systems. Identified as E3N-A 2000 PR122/P-LSIG In=2000A 3p F HR, this three-pole fixed breaker combines a 2000 A rated current with the ABB PR122/P-LSIG electronic overcurrent release.
As part of the ABB SACE Emax E3 platform, this UL 1066 breaker is designed for industrial, commercial and infrastructure installations requiring dependable high-current circuit protection. Its fixed construction and rear flat horizontal terminals provide a robust arrangement for permanent installation within compatible low-voltage switchgear.
The integrated PR122/P-LSIG electronic trip unit provides long-time, short-time, instantaneous and ground-fault protection. The breaker is also fitted with four auxiliary contacts and open/closed position indication, supporting status signalling and integration with switchboard monitoring and control systems.
Air circuit breakers such as the ABB SACE Emax E3N-A are used to switch and protect substantial low-voltage electrical loads. When abnormal current conditions occur, the electronic trip unit evaluates the fault against its configured protection settings and initiates circuit interruption when required, helping safeguard switchgear, conductors, transformers, generators and connected electrical equipment.
The PR122/P-LSIG release provides four principal protection functions. Long-time protection responds to sustained overload conditions, short-time protection supports controlled short-circuit response and selective coordination, instantaneous protection provides rapid interruption during severe short circuits, and ground-fault protection detects potentially damaging current flowing to earth.
| Product group | 310513-New Emax |
|---|---|
| Series | SACE Emax |
| ABB order code | 1SDA057387R1 |
| Product type | Air circuit breaker |
| Frame | E3 |
| Performance level | N |
| Rated current (In) | 2000 A |
| Rated operational current (Ie) | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Rated voltage (Ur) | 600 V |
| Overcurrent release rating | R2000 |
| Instantaneous reference | Im 30000 A |
| Number of poles | 3 |
| Execution | Fixed |
| Terminal arrangement | Rear flat horizontal |
| Trip unit | PR122/P-LSIG electronic overcurrent release |
| Protection functions | Long-time, short-time, instantaneous and ground-fault |
| Long-time protection | L |
| Short-time protection | S |
| Instantaneous protection | I |
| Ground-fault protection | G |
| Rated service short-circuit breaking capacity (Ics) at 240 V AC | 65 kA |
| Rated service short-circuit breaking capacity (Ics) at 480 V AC | 50 kA |
| Rated service short-circuit breaking capacity (Ics) at 600 V AC | 50 kA |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Current type | AC |
| Release type | Electronic |
| Standard | UL 1066 |
| Electrical durability | 8,000 cycles |
| Electrical operating frequency | 30 cycles per hour |
| Mechanical durability | 15,000 cycles |
| Mechanical operating frequency | 30 cycles per hour |
| Power loss | 130 W per pole at rated operating conditions |
| Product net width | 404 mm |
| Product net height | 418 mm |
| Product net depth | 302 mm |
| Net weight | 60 kg |
| EAN | 8015644596507 |
| HS code | 85362090 |
The ABB 1SDA057387R1 is a 2000 A three-pole SACE Emax E3N-A air circuit breaker used for switching and protecting low-voltage electrical distribution systems against overloads, short circuits and ground faults.
The breaker has a rated current of 2000 A and is equipped with an R2000 electronic overcurrent release configuration.
The 1SDA057387R1 is fitted with an ABB PR122/P-LSIG electronic overcurrent release, providing long-time, short-time, instantaneous and ground-fault protection.
This model is a three-pole fixed air circuit breaker with rear flat horizontal terminals for permanent installation within compatible SACE Emax low-voltage switchgear.
The rated service short-circuit breaking capacity is 65 kA at 240 V AC and 50 kA at both 480 V AC and 600 V AC.
ABB SACE Emax air circuit breakers provide dependable switching and electronic overcurrent protection for demanding low-voltage power distribution systems, combining robust breaker construction, high short-circuit performance and comprehensive LSIG protection for industrial, commercial and infrastructure applications.
We use cookies