ABB 1SDA057367R1 E3N-A 2000 PR121/P-LI is a 2000 A three-pole fixed SACE Emax air circuit breaker with LI electronic overcurrent protection for high-current low-voltage power distribution systems.

SKU: 1SDA057367R1MPN: 1SDA057367R1
Price
List Price £15,312.10 ex VAT
Your Price (ex VAT) Save 25%
£11,484.08 25% OFF
You save £3,828.03 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,484.08
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,484.08

Why Choose the ABB E3N-A 2000 PR121/P-LI 2000A 3P Fixed Air Circuit Breaker?

The ABB E3N-A 2000 PR121/P-LI, order code 1SDA057367R1, is a high-current SACE Emax air circuit breaker (ACB) designed for protection, switching and isolation in low-voltage power distribution systems. Built on the ABB E3N-A platform, this three-pole circuit breaker has a rated current of 2000 A and is intended for demanding industrial and commercial power distribution duties.

The breaker is equipped with an ABB PR121/P-LI electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection. This LI protection arrangement helps safeguard cables, busbars, switchgear and connected equipment against sustained overcurrents and severe short-circuit faults.

Configured as a three-pole fixed circuit breaker, the E3N-A 2000 PR121/P-LI is suited to permanent installation within low-voltage switchgear assemblies. Its 2000 A rated current, N performance level and electronic trip technology make it a dependable choice for main incomers, high-current feeders and major distribution circuits.

Key Advantages

  • High-capacity 2000 A SACE Emax air circuit breaker for major distribution circuits.
  • Three-pole fixed configuration for permanent switchboard installation.
  • Integrated PR121/P-LI electronic overcurrent release.
  • LI functionality provides long-time overload and instantaneous short-circuit protection.
  • N performance level for demanding low-voltage distribution applications.
  • Electronic trip technology provides dependable protection for high-current circuits.
  • Suitable for main incomer and high-current feeder protection.
  • ABB SACE Emax construction combines switching, isolation and circuit protection in one device.

Key Features

  • ABB SACE Emax E3N-A air circuit breaker.
  • 2000 A rated current.
  • Three-pole (3P) configuration.
  • Fixed (F) installation version.
  • PR121/P-LI electronic protection release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • N performance level.
  • Electronic overcurrent protection for critical distribution circuits.
  • Designed for high-current low-voltage power distribution.
  • Suitable for fixed switchboard and power distribution assemblies.

Reliable LI Protection for 2000A Power Distribution

Air circuit breakers such as the ABB SACE Emax E3N-A provide switching, isolation and overcurrent protection for major low-voltage distribution circuits. The PR121/P electronic release monitors current conditions and initiates circuit interruption when configured protection thresholds are exceeded, helping protect electrical infrastructure against damaging overload and short-circuit conditions.

The PR121/P-LI release combines long-time protection against sustained overloads with instantaneous protection against severe short-circuit currents. Together with the fixed E3N-A construction and 2000 A current rating, this provides a robust protection solution for high-capacity incomers, feeders and distribution circuits.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main incomer circuit protection.
  • High-current distribution feeders.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Transformer secondary distribution systems.
  • Power distribution centres.
  • Fixed low-voltage switchgear assemblies.

Technical Specifications

Series SACE Emax
ABB order code 1SDA057367R1
Product group 310513-New Emax
Product type Air circuit breaker (ACB)
Frame / size E3
Performance level N
Rated current (In) 2000 A
Number of poles 3P
Installation version Fixed
Trip unit PR121/P-LI electronic release
Protection functions Long-time (L), instantaneous (I)
Current type AC

Frequently Asked Questions

What is the ABB 1SDA057367R1 used for?

The ABB 1SDA057367R1 is a 2000 A three-pole SACE Emax air circuit breaker designed for protection, switching and isolation of high-current low-voltage power distribution circuits.

What trip unit is fitted to the ABB E3N-A 2000?

This circuit breaker is equipped with an ABB PR121/P-LI electronic release, providing long-time overload and instantaneous short-circuit protection.

What is the rated current of the ABB 1SDA057367R1?

The ABB E3N-A circuit breaker has a rated current of 2000 A.

What protection functions does PR121/P-LI provide?

The PR121/P-LI provides long-time protection against sustained overloads and instantaneous protection against severe short-circuit currents.

Is the ABB 1SDA057367R1 fixed or withdrawable?

The 1SDA057367R1 is a fixed three-pole circuit breaker intended for permanent installation within a compatible low-voltage switchgear assembly.

Trusted High-Current Protection from ABB

ABB SACE Emax air circuit breakers combine robust switching capability with electronic overcurrent protection for demanding low-voltage distribution systems, helping protect critical incomers, feeders and electrical infrastructure.