1SDA057339R1 ABB E2N-A 1600 PR121/P-LSI 1600A 3P Air Circuit Breaker

1SDA057339R1 ABB E2N-A 1600 PR121/P-LSI 1600A 3P Air Circuit Breaker

ABB 1SDA057339R1 E2N-A 1600 PR121/P-LSI is a 1600 A three-pole SACE Emax air circuit breaker with LSI electronic overcurrent protection for high-current low-voltage power distribution systems.

SKU: 1SDA057339R1MPN: 1SDA057339R1
Price
List Price £10,229.43 ex VAT
Your Price (ex VAT) Save 25%
£7,672.07 25% OFF
You save £2,557.36 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,672.07
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,672.07

Why Choose the ABB E2N-A 1600 PR121/P-LSI 1600A 3P Air Circuit Breaker?

The ABB E2N-A 1600 PR121/P-LSI, order code 1SDA057339R1, is a high-current SACE Emax air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. Built on the ABB E2N-A platform, this three-pole breaker has a rated current of 1600 A and is suited to major industrial, commercial and infrastructure distribution circuits.

The breaker is equipped with an ABB PR121/P-LSI electronic overcurrent release, providing long-time, short-time and instantaneous protection. This LSI protection arrangement helps safeguard cables, busbars, switchgear and connected equipment against sustained overloads and short-circuit currents while supporting coordinated protection throughout the electrical distribution network.

With its three-pole configuration, 1600 A rated current and N performance level, the E2N-A 1600 PR121/P-LSI provides dependable high-current circuit protection for main incomers and distribution feeders. ABB's SACE Emax platform combines robust switching performance with electronic protection for critical low-voltage installations.

Key Advantages

  • High-capacity 1600 A SACE Emax air circuit breaker for major distribution circuits.
  • Three-pole configuration for three-phase low-voltage systems.
  • Advanced PR121/P-LSI electronic overcurrent release.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • Short-time protection supports coordination with downstream protective devices.
  • N performance level for demanding power distribution applications.
  • Electronic trip technology provides dependable high-current circuit protection.
  • Suitable for main incomer and feeder protection in industrial switchboards.

Key Features

  • ABB SACE Emax E2N-A air circuit breaker.
  • 1600 A rated current.
  • Three-pole (3P) configuration.
  • PR121/P-LSI electronic protection release.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • N short-circuit performance level.
  • Electronic overcurrent protection for critical distribution circuits.
  • Suitable for selective protection strategies within low-voltage networks.
  • Designed for industrial and commercial power distribution systems.

Reliable LSI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E2N-A provide switching, isolation and overcurrent protection for major low-voltage distribution circuits. The PR121/P electronic release monitors circuit current and initiates tripping when configured protection thresholds are exceeded, helping protect electrical infrastructure from damaging overload and short-circuit conditions.

The PR121/P-LSI release combines long-time protection against sustained overloads with short-time and instantaneous short-circuit protection. The short-time function provides additional flexibility for coordinating upstream and downstream protective devices, helping improve selectivity and reduce unnecessary interruption of unaffected sections of the distribution system.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main incomer circuit protection.
  • High-current distribution feeders.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Infrastructure electrical systems.
  • Transformer secondary distribution.
  • Power distribution centres and switchgear assemblies.

Technical Specifications

Series SACE Emax
ABB order code 1SDA057339R1
Product group 310513-New Emax
Product type Air circuit breaker (ACB)
Frame / size E2
Performance level N
Rated current (In) 1600 A
Number of poles 3P
Trip unit PR121/P-LSI electronic release
Protection functions Long-time (L), short-time (S), instantaneous (I)
Current type AC

Frequently Asked Questions

What is the ABB 1SDA057339R1 used for?

The ABB 1SDA057339R1 is a 1600 A three-pole SACE Emax air circuit breaker designed for protection, switching and isolation of high-current low-voltage power distribution circuits.

What trip unit is fitted to the ABB E2N-A 1600?

This circuit breaker is equipped with an ABB PR121/P-LSI electronic release, providing long-time, short-time and instantaneous overcurrent protection.

What is the rated current of the ABB 1SDA057339R1?

The ABB E2N-A circuit breaker has a rated current of 1600 A.

What protection functions does PR121/P-LSI provide?

The PR121/P-LSI provides long-time overload protection together with short-time and instantaneous short-circuit protection.

What applications suit the ABB E2N-A 1600 PR121/P-LSI?

The breaker is suited to main incomers, high-current feeders, industrial switchboards, transformer secondary distribution and power distribution centres requiring electronic LSI overcurrent protection.

Trusted Power Distribution Protection from ABB

ABB SACE Emax air circuit breakers combine robust power switching with electronic overcurrent protection for demanding low-voltage distribution systems, helping protect critical incomers, feeders and electrical infrastructure.