ABB 1SDA057277R1 E2B-A 1600 PR121/P-LSI is a 1600 A three-pole SACE Emax air circuit breaker with a PR121/P-LSI electronic overcurrent release providing long-time, short-time and instantaneous protection for low-voltage power distribution.

SKU: 1SDA057277R1MPN: 1SDA057277R1
Price
List Price £11,354.87 ex VAT
Your Price (ex VAT) Save 25%
£8,516.15 25% OFF
You save £2,838.72 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,516.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,516.15

Why Choose the ABB E2B-A 1600 PR121/P-LSI 1600 A Air Circuit Breaker?

The ABB E2B-A 1600 PR121/P-LSI, order code 1SDA057277R1, is a SACE Emax E2B-A air circuit breaker designed for protection, switching and isolation in low-voltage power distribution systems. Rated at 1600 A, this three-pole breaker combines ABB's E2 frame with a PR121/P-LSI electronic overcurrent release.

As part of the ABB SACE Emax family, this breaker is suited to industrial switchboards, distribution systems and infrastructure applications requiring reliable electronic overcurrent protection. The PR121/P-LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection for important incoming and feeder circuits.

With its 1600 A rating and three-pole configuration, the E2B-A 1600 provides a robust solution for three-phase power distribution. Its LSI protection functions support selective coordination strategies while helping protect conductors, busbars, transformers and connected equipment against damaging overcurrent and short-circuit conditions.

Key Advantages

  • 1600 A rated current for substantial low-voltage power distribution circuits.
  • PR121/P-LSI electronic overcurrent release for dependable circuit protection.
  • LSI protection functions provide long-time overload, short-time short-circuit and instantaneous short-circuit protection.
  • Three-pole configuration for three-phase electrical distribution systems.
  • Short-time protection supports selective coordination with downstream protective devices.
  • Electronic trip technology provides accurate protection for high-current circuits.
  • Suitable for incoming, feeder and transformer secondary protection duties.
  • Part of ABB's proven SACE Emax E2 air circuit breaker platform.

Key Features

  • ABB SACE Emax E2B-A series.
  • 1600 A rated current.
  • Three-pole configuration.
  • PR121/P-LSI electronic overcurrent release.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Electronic overcurrent protection technology.
  • Designed for high-current low-voltage distribution circuits.
  • Suitable for industrial, commercial and infrastructure switchboards.

Advanced LSI Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax E2 provide switching, isolation and overcurrent protection for substantial low-voltage electrical distribution systems. The E2 frame and 1600 A current rating make this configuration suitable for important incoming and feeder circuits where dependable operation and effective fault protection are essential.

The PR121/P-LSI electronic release combines long-time overload, short-time short-circuit and instantaneous short-circuit protection. The short-time function supports selective coordination with downstream protective devices, helping minimise unnecessary interruption while protecting busbars, conductors, transformers and connected equipment against fault currents.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial incoming and feeder circuits.
  • Manufacturing and process plant electrical systems.
  • Commercial building power distribution.
  • Transformer secondary distribution circuits.
  • High-current feeder and busbar protection.
  • Infrastructure and critical low-voltage power systems.

Technical Specifications

Series SACE Emax
Frame E2
Performance level B-A
ABB order code 1SDA057277R1
Product group 310513-New Emax
Product type Air circuit breaker
Rated current 1600 A
Number of poles 3
Trip unit PR121/P-LSI
Trip unit rated current 1600 A
Protection functions L, S, I
Long-time protection Overload protection
Short-time protection Delayed short-circuit protection
Instantaneous protection Short-circuit protection
Protection type Electronic overcurrent protection
Breaker family Emax E2B-A

Frequently Asked Questions

What is the ABB E2B-A 1600 PR121/P-LSI used for?

This SACE Emax air circuit breaker is designed for switching and protecting high-current low-voltage power distribution circuits in industrial, commercial and infrastructure installations.

What is the rated current of the ABB 1SDA057277R1?

The ABB 1SDA057277R1 has a rated current of 1600 A and is equipped with a PR121/P-LSI electronic overcurrent release.

What protection functions does the PR121/P-LSI trip unit provide?

The PR121/P-LSI provides LSI protection, comprising long-time overload, short-time short-circuit and instantaneous short-circuit protection.

How many poles does the ABB E2B-A 1600 PR121/P-LSI have?

ABB order code 1SDA057277R1 is a three-pole air circuit breaker configuration for three-phase low-voltage distribution systems.

Where is the ABB E2B-A 1600 PR121/P-LSI typically used?

It is suited to main switchboards, industrial distribution systems, transformer secondary circuits and high-current feeders requiring electronic LSI overcurrent protection.

Trusted by Electrical Professionals Worldwide

ABB SACE Emax air circuit breakers are engineered for dependable low-voltage power distribution, combining robust high-current switching capability with electronic overcurrent protection for industrial switchboards, infrastructure and critical electrical systems.