1sda057186r1  t4s 250 ul/csa tmd 40-500 3 pole abb mccb

1sda057186r1 t4s 250 ul/csa tmd 40-500 3 pole abb mccb

ABB 1SDA057186R1 Tmax T4S 250 UL/CSA moulded case circuit breaker with TMD thermomagnetic release, 40 A rating, three-pole fixed configuration and front terminals for industrial circuit protection.

SKU: 1SDA057186R1Alt SKU: T4S 250 UL/CSA TMD 40-500 3p F FMPN: 1SDA057186R1
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the ABB 1SDA057186R1 Tmax T4S 250 UL/CSA MCCB?

The ABB 1SDA057186R1 is a dependable Tmax T4S 250 UL/CSA moulded case circuit breaker (MCCB) designed for reliable protection in industrial and commercial electrical distribution systems. As part of the ABB SACE Tmax T series, it provides robust overload and short circuit protection for switchboards, machinery panels, OEM equipment and power distribution installations.

This breaker is supplied as a fixed three-pole MCCB with front terminals and a TMD thermomagnetic release, providing combined thermal overload and magnetic short circuit protection. Its UL/CSA format makes it suitable for applications requiring North American approval standards, including export machinery, control panels and internationally specified electrical systems.

With a 40 A rated current, three-pole configuration and compact Tmax T4S frame, the ABB 1SDA057186R1 is well suited to industrial distribution and machinery applications where reliability, safety and straightforward installation are essential.

Key Advantages

  • ABB Tmax T4S 250 UL/CSA MCCB for dependable industrial circuit protection.
  • 40 A rated current suitable for machinery, control panels and distribution circuits.
  • Three-pole fixed configuration with front terminal connections.
  • TMD thermomagnetic release for overload and short circuit protection.
  • Adjustable magnetic protection up to 500 A for flexible installation requirements.
  • Suitable for UL/CSA compliant panel building and export machinery.
  • Compact ABB MCCB design for switchboards, control panels and OEM equipment.

Key Features

  • ABB SACE Tmax T series.
  • T4S 250 frame size.
  • UL/CSA approved moulded case circuit breaker.
  • 40 A rated current.
  • Three-pole MCCB.
  • Fixed version with front terminals.
  • TMD thermomagnetic trip unit.
  • Thermal and magnetic protection for industrial circuit protection.
  • Designed for electrical distribution, machinery, OEM panels and control systems.

Reliable Thermomagnetic Protection for Industrial Installations

Moulded case circuit breakers such as the ABB 1SDA057186R1 protect electrical circuits against overload and short circuit faults. The thermal element responds to sustained overcurrent conditions, while the magnetic element provides rapid tripping under short circuit conditions.

The TMD thermomagnetic release provides a practical and dependable protection solution for distribution and machinery circuits. Its compact fixed construction and front terminal layout make it straightforward to install within switchboards, machine cabinets and control panel assemblies.

Typical Applications

  • Industrial switchboards and distribution panels.
  • Machinery control panels.
  • OEM control systems and export machinery.
  • Commercial electrical distribution.
  • Automation and manufacturing equipment.
  • UL/CSA compliant panel building applications.
  • Three-phase circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Current 40 A
Phase Three Phase
Poles 3-pole
Device Type MCCB
Trip Unit Thermal-magnetic
Manufacturer ABB
Series SACE Tmax T
Model T4S 250 UL/CSA TMD 40-500 3P F F
Product code 1SDA057186R1
Alternative SKU T4S250UL/CSATMD40-5003PFF
Product type Moulded case circuit breaker
Frame size T4S 250
Rated current 40 A
Number of poles 3 pole
Trip unit TMD thermomagnetic release
Thermal protection Fixed / adjustable by breaker configuration
Magnetic protection Up to 500 A
Version Fixed
Terminal type Front terminals
Approvals UL/CSA
Mounting type Panel / switchboard mounting

Frequently Asked Questions

What is the ABB 1SDA057186R1 used for?

The ABB 1SDA057186R1 is used for overload and short circuit protection in industrial and commercial electrical distribution systems.

What current rating does this MCCB have?

This model has a 40 A rated current.

How many poles does the ABB 1SDA057186R1 have?

The breaker is supplied as a three-pole MCCB.

What trip unit is fitted to this breaker?

The ABB 1SDA057186R1 uses a TMD thermomagnetic release.

Is this breaker suitable for UL/CSA applications?

Yes, this is a UL/CSA version of the ABB Tmax T4S MCCB, suitable for applications requiring North American approval standards.

Trusted by Panel Builders Worldwide

ABB Tmax moulded case circuit breakers are widely used by electrical engineers, OEMs and panel builders for reliable circuit protection, compact installation and dependable performance in demanding industrial environments.