1SDA057148R1 ABB E6V6300 PR122/P-LSI 6300A 4P Fixed Air Circuit Breaker

1SDA057148R1 ABB E6V6300 PR122/P-LSI 6300A 4P Fixed Air Circuit Breaker

ABB 1SDA057148R1 E6V6300 PR122/P-LSI is a 6300 A four-pole fixed SACE Emax air circuit breaker with an electronic LSI overcurrent release for high-current low-voltage power distribution protection.

SKU: 1SDA057148R1MPN: 1SDA057148R1
Price
List Price £98,203.25 ex VAT
Your Price (ex VAT) Save 25%
£73,652.44 25% OFF
You save £24,550.81 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £73,652.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£73,652.44

Why Choose the ABB E6V6300 PR122/P-LSI 6300A 4P Fixed Air Circuit Breaker?

The ABB E6V6300 PR122/P-LSI, order code 1SDA057148R1, is a high-performance SACE Emax air circuit breaker (ACB) designed for protection and switching of high-current low-voltage electrical distribution systems. Part of the established ABB SACE Emax E6 series, this four-pole circuit breaker combines a 6300 A rated current with ABB's V short-circuit performance level for demanding industrial and infrastructure applications.

This fixed-version E6V circuit breaker is equipped with an ABB PR122/P-LSI electronic overcurrent release, providing long-time, short-time and instantaneous protection functions. The electronic trip unit enables effective protection against overload and short-circuit conditions while supporting selective coordination within complex low-voltage distribution networks.

With its four-pole configuration, fixed installation arrangement and rear horizontal terminals, the E6V6300 PR122/P-LSI is engineered for substantial switchboards and power distribution assemblies. The breaker has a rated operational voltage up to 690 V AC, a rated insulation voltage of 1000 V and a rated impulse withstand voltage of 12 kV.

Key Advantages

  • High-capacity 6300 A SACE Emax air circuit breaker for demanding power distribution systems.
  • Four-pole fixed configuration suitable for switching and protecting three-phase systems with neutral.
  • Advanced PR122/P-LSI electronic overcurrent release.
  • LSI protection provides long-time, short-time and instantaneous protection functions.
  • V performance level provides high short-circuit breaking capability.
  • Rated operational voltage up to 690 V AC.
  • Rear horizontal terminals support integration into high-current switchboard assemblies.
  • Designed for reliable protection and isolation of critical low-voltage distribution circuits.

Key Features

  • ABB SACE Emax E6V air circuit breaker.
  • 6300 A rated current.
  • Four-pole (4P) configuration.
  • Fixed circuit-breaker version.
  • PR122/P-LSI electronic release.
  • Long-time (L), short-time (S) and instantaneous (I) overcurrent protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Rear horizontal terminal arrangement.
  • High V-level short-circuit performance.
  • Supplied with auxiliary contacts and open/closed position indication.

Reliable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E6V are used to protect major feeders, incomers and distribution circuits against damaging overload and short-circuit currents. The E6V6300 combines a high continuous-current rating with substantial short-circuit interruption capability, making it suitable for installations where dependable protection and system availability are critical.

The integrated PR122/P-LSI electronic trip unit continuously monitors current and provides long-time, short-time and instantaneous protection. This combination enables the breaker to respond appropriately to different overcurrent conditions and assists engineers in achieving selective protection across large low-voltage distribution networks.

Typical Applications

  • Main incomers for high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Large manufacturing and process plants.
  • Power generation and utility distribution equipment.
  • Commercial and infrastructure electrical installations.
  • Transformer secondary protection.
  • High-current feeder protection and isolation.
  • Low-voltage power distribution centres and switchgear assemblies.

Technical Specifications

Series SACE Emax
ABB order code 1SDA057148R1
Product type Air circuit breaker (ACB)
Frame / size E6
Performance level V
Rated current (In) 6300 A
Rated uninterrupted current (Iu) 6300 A
Number of poles 4P
Installation version Fixed
Trip unit PR122/P-LSI electronic release
Protection functions Long-time (L), short-time (S), instantaneous (I)
Rated operational voltage up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400 / 415 V AC 150 kA
Rated service short-circuit breaking capacity (Ics) at 400 / 415 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) at 690 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 85 kA
Terminal arrangement Rear horizontal
Mechanical durability 12,000 operating cycles
Power loss 650 W
Standard IEC
EAN 8015644584887

Frequently Asked Questions

What is the ABB 1SDA057148R1 used for?

The ABB 1SDA057148R1 is a 6300 A four-pole SACE Emax air circuit breaker designed for protection and switching of high-current low-voltage power distribution circuits.

What trip unit is fitted to this E6V6300 circuit breaker?

This circuit breaker is equipped with an ABB PR122/P-LSI electronic overcurrent release, providing long-time, short-time and instantaneous protection functions.

What is the rated current of the ABB E6V6300 PR122/P-LSI?

The circuit breaker has a rated current of 6300 A and is intended for high-current low-voltage distribution applications.

Is the ABB 1SDA057148R1 a fixed or withdrawable circuit breaker?

The 1SDA057148R1 is a fixed-version circuit breaker with a four-pole configuration and rear horizontal terminals.

What is the maximum rated operational voltage?

The E6V6300 PR122/P-LSI has a rated operational voltage up to 690 V AC, with a rated insulation voltage of 1000 V.

Trusted High-Current Protection from ABB

ABB SACE Emax air circuit breakers are engineered for dependable protection, switching and isolation in demanding low-voltage power distribution systems, combining high current capability with advanced electronic protection technology.