1SDA057132R1 ABB E6V5000 PR122/P-LSI 5000A 4-Pole Withdrawable Air Circuit Breaker Moving Part

1SDA057132R1 ABB E6V5000 PR122/P-LSI 5000A 4-Pole Withdrawable Air Circuit Breaker Moving Part

ABB 1SDA057132R1 SACE Emax E6V5000 four-pole withdrawable air circuit breaker moving part with a 5000 A rated current, PR122/P-LSI R5000 electronic protection release and ultimate short-circuit breaking capacity of up to 150 kA.

SKU: 1SDA057132R1MPN: 1SDA057132R1
Price
List Price £95,757.37 ex VAT
Your Price (ex VAT) Save 25%
£71,818.03 25% OFF
You save £23,939.34 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £71,818.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£71,818.03

Why Choose the ABB E6V5000 PR122/P-LSI 5000A 4-Pole Withdrawable Air Circuit Breaker?

The ABB 1SDA057132R1 is a high-performance SACE Emax E6V air circuit breaker moving part designed for protection and switching of high-current low-voltage electrical distribution systems. Part of the ABB New Emax series, the E6V5000 combines a 5000 A current rating with the PR122/P-LSI electronic overcurrent release for dependable protection in demanding industrial, commercial and infrastructure power distribution applications.

This four-pole withdrawable circuit breaker moving part is equipped with the PR122/P-LSI R5000 electronic trip unit. Its LSI protection functions provide long-time overload (L), selective short-circuit (S) and instantaneous short-circuit (I) protection, supporting coordinated protection strategies in high-capacity electrical distribution networks.

The E6V5000 provides an ultimate short-circuit breaking capacity of up to 150 kA at 220–440 V AC, with 130 kA at 500 V AC and 100 kA at 660–690 V AC. Combined with its 5000 A current capability, four-pole construction and withdrawable configuration, the 1SDA057132R1 is suited to critical distribution systems requiring high fault-clearing performance and serviceable switchgear.

Key Advantages

  • High-capacity 5000 A air circuit breaker moving part for low-voltage power distribution.
  • Four-pole configuration for three-phase systems requiring neutral switching.
  • Advanced PR122/P-LSI R5000 electronic protection release.
  • LSI protection provides long-time overload, selective short-circuit and instantaneous short-circuit protection.
  • Ultimate short-circuit breaking capacity of up to 150 kA.
  • Withdrawable moving-part design supports maintenance and servicing of critical switchgear.
  • Four auxiliary contacts with circuit-breaker open / closed position indication.
  • High short-time withstand capability for demanding electrical distribution systems.

Key Features

  • ABB SACE Emax E6V series.
  • 5000 A rated operational and uninterrupted current.
  • 4-pole withdrawable moving part.
  • PR122/P-LSI R5000 electronic trip unit.
  • Long-time overload (L) protection.
  • Selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Ultimate short-circuit breaking capacity up to 150 kA.
  • 100 kA short-time withstand current for 1 s.
  • 85 kA short-time withstand current for 3 s.
  • V high short-circuit performance level.
  • Four auxiliary contacts with open / closed position indication.

High-Performance Protection for Critical Power Distribution

Air circuit breakers such as the ABB SACE Emax E6V5000 provide switching and protection for high-current low-voltage distribution circuits. The electronic trip unit monitors electrical conditions and initiates circuit interruption when configured protection thresholds are exceeded, helping protect busbars, cables, transformers and connected equipment against damaging overload and short-circuit currents.

The PR122/P-LSI release combines long-time overload, selective short-circuit and instantaneous short-circuit protection, supporting coordinated protection within complex electrical distribution networks. Together with the E6V5000's 5000 A current capability, short-circuit breaking capacity of up to 150 kA, four-pole construction and withdrawable design, the 1SDA057132R1 is particularly suited to critical installations requiring robust protection and maintainable switchgear.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Withdrawable industrial switchgear assemblies.
  • High-current incoming and feeder circuits.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Transformer secondary protection and switching.
  • Generator and utility distribution systems.
  • Four-wire electrical systems requiring neutral switching.

Technical Specifications

Series SACE Emax / New Emax
Order code 1SDA057132R1
Product group 310513-New Emax
Product type Air circuit breaker moving part
Frame / sub-type E6
Short-circuit performance level V
Rated current (In) 5000 A
Rated operational current (Ie) 5000 A
Rated uninterrupted current (Iu) 5000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 4
Trip unit PR122/P-LSI R5000
Trip unit type Electronic
Protection functions Long-time overload, selective short-circuit and instantaneous short-circuit protection (LSI)
Ultimate short-circuit breaking capacity (Icu), 220–440 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu), 500 V AC 130 kA
Ultimate short-circuit breaking capacity (Icu), 660–690 V AC 100 kA
Service short-circuit breaking capacity (Ics), 220–415 V AC 150 kA
Service short-circuit breaking capacity (Ics), 440 V AC 125 kA
Service short-circuit breaking capacity (Ics), 500–690 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 85 kA
Version Withdrawable
Installation component Moving part (MP)
Terminal connection type Withdrawable circuit breaker
Auxiliary contacts 4 contacts with open / closed circuit-breaker position indication
Power loss 700 W
Electrical durability at Ue ≤ 440 V 3000 cycles
Electrical durability at Ue 500–690 V 2000 cycles
Mechanical durability 12,000 cycles
Maximum electrical operating frequency 10 cycles per hour
Maximum mechanical operating frequency 60 cycles per hour
Dimensions (W × H × D) 936 × 461 × 396.5 mm
Net weight 134 kg
EAN 8015644584726
Customs tariff number 85362090
Current type AC
Reference standard IEC

Frequently Asked Questions

What is the ABB 1SDA057132R1 used for?

The ABB 1SDA057132R1 is a 5000 A four-pole withdrawable air circuit breaker moving part designed for switching and protection of high-current low-voltage electrical distribution systems.

What is the current rating of the ABB E6V5000?

The E6V5000 has a rated operational and uninterrupted current of 5000 A, making it suitable for major high-capacity power distribution applications.

What protection unit is fitted to the ABB 1SDA057132R1?

The circuit breaker is fitted with an electronic ABB PR122/P-LSI R5000 overcurrent release providing long-time overload, selective short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E6V5000?

The E6V5000 has an ultimate short-circuit breaking capacity of 150 kA at 220–440 V AC, 130 kA at 500 V AC and 100 kA at 660–690 V AC.

Is the ABB 1SDA057132R1 fixed or withdrawable?

The 1SDA057132R1 is a four-pole withdrawable moving part designed for use with the corresponding fixed part of an ABB SACE Emax E6 withdrawable circuit-breaker installation.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers are engineered for reliable protection and switching in demanding low-voltage power distribution systems, combining high current capacity, advanced electronic protection, robust short-circuit performance and serviceable withdrawable configurations for industrial and infrastructure applications.