ABB 1SDA057129R1 E6V5000 PR121/P-LSI is a 5000 A four-pole withdrawable SACE Emax air circuit breaker moving part with electronic LSI protection and high short-circuit performance for demanding low-voltage power distribution systems.
£71,710.77
The ABB 1SDA057129R1, product designation E6V5000PR121/P-LSIIn=5000A4pW, is a high-performance SACE Emax air circuit breaker moving part designed for switching and protection in demanding low-voltage electrical distribution systems. Part of the ABB SACE Emax E6V series, this four-pole withdrawable unit combines a 5000 A rated current with the PR121/P-LSI electronic overcurrent release.
The E6V5000 is engineered for high-current industrial, commercial and infrastructure distribution applications where dependable overload and short-circuit protection is essential. Its PR121/P-LSI electronic trip unit provides long-time, short-time and instantaneous protection functions, helping protect busbars, cables, switchgear and connected equipment while supporting selective coordination within complex electrical distribution networks.
This version uses a four-pole withdrawable configuration for integration with compatible ABB SACE Emax switchgear. The E6V performance class provides substantial fault-clearing capability, including an ultimate short-circuit breaking capacity of 150 kA at 415 V AC, making it suitable for installations with high prospective fault currents.
Air circuit breakers such as the ABB SACE Emax E6V5000 provide switching and protection for high-capacity low-voltage distribution networks. With a rated current of 5000 A and V-level short-circuit performance, the E6V platform is particularly suited to main incoming supplies, large switchboards, transformer secondary systems and industrial distribution networks where substantial electrical loads and high prospective fault currents must be safely managed.
The PR121/P-LSI electronic release provides three complementary protection functions. Long-time protection responds to sustained overload conditions, short-time protection enables controlled fault clearing and supports selective coordination, and instantaneous protection provides rapid interruption during severe short-circuit faults. The withdrawable construction further supports maintainability by allowing the breaker moving part to be removed from its compatible fixed section when inspection, servicing or replacement is required.
| Series | SACE Emax E6V |
|---|---|
| ABB product group | 310513-New Emax |
| ABB order code | 1SDA057129R1 |
| Product designation | E6V5000PR121/P-LSIIn=5000A4pW |
| Product type | Air circuit breaker moving part |
| Rated current (In) | 5000 A |
| Rated operational current (Ie) | 5000 A |
| Rated uninterrupted current (Iu) | 5000 A |
| Number of poles | 4 |
| Version | Withdrawable |
| Trip unit | PR121/P-LSI |
| Release type | Electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Performance level | V |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 660–690 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 400–415 V AC | 150 kA |
| Rated service short-circuit breaking capacity (Ics) at 440 V AC | 125 kA |
| Rated service short-circuit breaking capacity (Ics) at 500 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 660–690 V AC | 100 kA |
| Rated short-time withstand current (Icw) | 100 kA for 1 s; 85 kA for 3 s |
| Standard | IEC |
The ABB 1SDA057129R1 is a SACE Emax E6V air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution systems, including main switchboards, transformer secondary systems and major industrial installations.
The E6V5000 has a rated current of 5000 A, making it suitable for high-current industrial, commercial and infrastructure power distribution applications.
The PR121/P-LSI electronic overcurrent release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection functions.
The E6V5000 provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC. Its rated short-time withstand current is 100 kA for 1 s and 85 kA for 3 s, supporting demanding high-current distribution applications.
The 1SDA057129R1 is a four-pole withdrawable air circuit breaker moving part designed for use with a compatible ABB SACE Emax fixed part.
ABB SACE Emax air circuit breakers are engineered for dependable switching and protection in demanding low-voltage power distribution systems, combining high current capacity and substantial short-circuit performance with electronic protection for industrial, commercial and infrastructure installations.