ABB 1SDA056936R1 E4V4000 PR121/P-LI is a 4000 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LI electronic release providing long-time overload and instantaneous short-circuit protection.

SKU: 1SDA056936R1MPN: 1SDA056936R1
Price
List Price £55,513.13 ex VAT
Your Price (ex VAT) Save 25%
£41,634.85 25% OFF
You save £13,878.28 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £41,634.85
Trade pricing is personalised to your account

Manufacturer Lead Time

£41,634.85

Why Choose the ABB E4V4000 PR121/P-LI 4000A 4P Withdrawable Air Circuit Breaker?

The ABB E4V4000 PR121/P-LI, order code 1SDA056936R1, is a high-performance SACE Emax E4V air circuit breaker moving part designed for protection and switching in demanding low-voltage electrical distribution systems. Rated at 4000 A, this four-pole withdrawable configuration combines the ABB SACE Emax platform with a PR121/P-LI R4000 electronic overcurrent release.

The PR121/P-LI release provides long-time (L) and instantaneous (I) overcurrent protection, helping protect electrical installations against sustained overloads and severe short-circuit conditions. The E4V performance level delivers substantial fault-interruption capability, including 150 kA ultimate and service short-circuit breaking capacity at 400–440 V AC and 100 kA at 690 V AC.

This version is supplied as the four-pole withdrawable moving part of the E4V4000 circuit breaker and is designed for use with the corresponding ABB SACE Emax fixed part. Its withdrawable construction facilitates inspection, maintenance and replacement in critical switchboards, while the 690 V AC operational rating and high short-circuit performance make it suitable for demanding industrial, commercial and infrastructure power systems.

Key Advantages

  • High-current 4000 A SACE Emax E4V circuit breaker moving part for demanding low-voltage distribution.
  • Four-pole configuration supports four-conductor electrical distribution systems.
  • PR121/P-LI R4000 electronic release provides long-time and instantaneous overcurrent protection.
  • Withdrawable moving-part construction facilitates inspection, maintenance and replacement.
  • High 150 kA Icu and Ics at 400–440 V AC for systems with substantial prospective fault levels.
  • Maintains 100 kA Icu and Ics at 690 V AC.
  • 100 kA short-time withstand current for 1 s supports demanding distribution applications.
  • Rated for operation up to 690 V AC.

Key Features

  • ABB SACE Emax E4V series.
  • 4000 A rated current.
  • Four-pole circuit-breaker configuration.
  • PR121/P-LI R4000 electronic overcurrent release.
  • Long-time overload protection (L).
  • Instantaneous short-circuit protection (I).
  • Withdrawable moving-part execution.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • E4 V short-circuit performance level.
  • IEC-compliant SACE Emax construction.

High-Performance 4000A Protection with Withdrawable Serviceability

The ABB SACE Emax E4V platform is engineered for high-capacity low-voltage distribution systems where exceptional short-circuit performance and dependable electronic protection are required. The PR121/P-LI release combines long-time overload protection with instantaneous short-circuit protection, helping safeguard busbars, feeders and connected electrical equipment against damaging overcurrent conditions.

The withdrawable E4V4000 configuration is particularly suited to critical switchboards where serviceability and operational flexibility are important. Its 4000 A rating, 150 kA breaking capacity at 400–440 V AC and 100 kA breaking capacity at 690 V AC provide substantial protection capability, while the moving-part construction allows the breaker to be withdrawn from its corresponding fixed part for inspection, maintenance or replacement.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • High-capacity industrial power distribution systems.
  • Main incoming and high-current feeder protection.
  • Installations with high prospective short-circuit currents.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry switchgear.
  • Transformer and generator distribution systems.
  • Switchboards requiring withdrawable circuit breakers for improved serviceability.

Technical Specifications

Series SACE Emax E4V
ABB order code 1SDA056936R1
Product group 310513-New Emax
Product type Air circuit breaker moving part
Rated current (In) 4000 A
Rated operational current (Ie) 4000 A
Rated uninterrupted current (Iu) 4000 A
Number of poles 4
Execution Withdrawable
Component Moving part
Protection release PR121/P-LI
Release type Electronic
Protection functions Long-time (L) and instantaneous (I)
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 130 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 415 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 440 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 130 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Short-circuit performance level V
Mechanical endurance 15000 cycles
Mechanical operating frequency 60 cycles per hour
Electrical endurance at ≤440 V AC 5000 cycles
Electrical endurance at 500–690 V AC 4000 cycles
Electrical operating frequency 10 cycles per hour
Power loss 660 W
Dimensions (W × H × D) 684 × 461 × 396.5 mm
Net weight 96 kg
Standard IEC
EAN 8015644582760
HS code 85362090

Frequently Asked Questions

What is the ABB 1SDA056936R1?

The ABB 1SDA056936R1 is the withdrawable moving part of an E4V4000 SACE Emax air circuit breaker rated at 4000 A, with four poles and a PR121/P-LI electronic overcurrent release.

What is the rated current of the E4V4000 PR121/P-LI?

The ABB E4V4000 PR121/P-LI 1SDA056936R1 has a rated operational and uninterrupted current of 4000 A.

What protection functions does the PR121/P-LI release provide?

The PR121/P-LI electronic release provides long-time overload protection (L) and instantaneous short-circuit protection (I).

Is ABB 1SDA056936R1 fixed or withdrawable?

ABB 1SDA056936R1 is a withdrawable four-pole circuit-breaker moving part designed for use with the corresponding ABB SACE Emax fixed part.

What is the short-circuit breaking capacity of ABB 1SDA056936R1?

The E4V4000 provides ultimate and service short-circuit breaking capacities of 150 kA at 400–440 V AC, 130 kA at 500 V AC and 100 kA at 690 V AC.

What is the rated operational voltage of ABB 1SDA056936R1?

The E4V4000 PR121/P-LI is rated for operation at 690 V AC, with a rated insulation voltage of 1000 V and rated impulse withstand voltage of 12 kV.

What are the dimensions and weight of ABB 1SDA056936R1?

The ABB 1SDA056936R1 measures approximately 684 × 461 × 396.5 mm and has a net product weight of 96 kg.

Trusted by Electrical Engineers Worldwide

ABB SACE Emax air circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems where dependable high-current switching, electronic overcurrent protection, high short-circuit performance and serviceable withdrawable construction are required.