Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056924R1 E4V 4000 four-pole fixed SACE Emax air circuit breaker rated at 4000 A with rear horizontal terminals and a PR122/P-LSI R4000 electronic overcurrent release.
£36,344.06
The ABB E4V 4000 PR122/P-LSI, order code 1SDA056924R1, is a high-performance four-pole fixed air circuit breaker (ACB) designed for protection and switching in high-current low-voltage electrical distribution systems. Part of the proven ABB SACE Emax E4 series, it combines a rated uninterrupted current of 4000 A with the advanced PR122/P-LSI R4000 electronic overcurrent release.
The E4V performance level provides very high short-circuit interruption capability for demanding industrial, commercial and infrastructure power systems. Its PR122/P-LSI electronic release provides long-time, short-time and instantaneous protection functions, helping protect conductors, switchboards and connected equipment against overload and short-circuit conditions while supporting selective protection coordination.
This configuration is a four-pole fixed circuit breaker with rear flat horizontal terminals. Rated for operation up to 690 V AC and providing an ultimate short-circuit breaking capacity of 150 kA at 400 V AC, the E4V 4000 is well suited to major switchboards, transformer distribution systems, industrial power centres and other installations with substantial prospective fault currents.
Air circuit breakers such as the ABB E4V 4000 provide primary switching and protection for high-current low-voltage electrical systems. The E4V performance level is designed for installations with particularly high prospective fault currents, combining a continuous current capability of 4000 A with short-circuit interruption performance reaching 150 kA at common industrial voltages.
The PR122/P-LSI electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. These functions enable protection settings to be coordinated across the distribution system, helping achieve reliable fault clearance and selectivity for major incoming supplies, feeders and critical electrical loads.
| Product family | SACE Emax |
|---|---|
| Series / frame | E4V |
| ABB order code | 1SDA056924R1 |
| EAN | 8015644582647 |
| Product type | Air circuit breaker (ACB) |
| Rated current (In) | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated operational current (Ie) | 4000 A |
| Number of poles | 4 |
| Version | Fixed |
| Terminal connection | Rear flat horizontal |
| Trip unit | PR122/P-LSI electronic release |
| Rating plug | R4000 |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–440 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 660–690 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 220–440 V AC | 150 kA |
| Rated service short-circuit breaking capacity (Ics) at 500 V AC | 130 kA |
| Rated service short-circuit breaking capacity (Ics) at 660–690 V AC | 100 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Current type | AC |
| Release type | Electronic |
| Short-circuit performance level | V |
| Standard | IEC |
| Power loss | 360 W |
| Mechanical durability | 15,000 operating cycles |
| Electrical durability at ≤440 V | 5,000 operating cycles |
| Electrical durability at 500–690 V | 4,000 operating cycles |
| Dimensions (W × H × D) | 656 × 418 × 302 mm |
| Product net weight | 92 kg |
The ABB 1SDA056924R1 is an E4V 4000 four-pole fixed SACE Emax air circuit breaker rated at 4000 A and equipped with a PR122/P-LSI R4000 electronic overcurrent release.
The PR122/P-LSI provides long-time overload, short-time short-circuit and instantaneous short-circuit protection functions.
The E4V 4000 has an ultimate short-circuit breaking capacity of 150 kA at 220–440 V AC, 130 kA at 500 V AC and 100 kA at 660–690 V AC.
This model is a fixed four-pole air circuit breaker with rear flat horizontal main terminals for integration into compatible low-voltage switchgear assemblies.
It is designed for high-current low-voltage distribution applications including industrial switchboards, transformer distribution systems, power centres, data centres, large commercial facilities and critical infrastructure installations.
ABB SACE Emax air circuit breakers provide high-performance switching and protection for demanding low-voltage power distribution systems, combining high current capacity, advanced electronic protection and substantial short-circuit interruption capability.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.