Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056909R1 is a four-pole 3200 A SACE Emax E4V withdrawable air circuit breaker moving part with PR122/P-LSIG electronic protection and a 150 kA ultimate short-circuit breaking capacity at 400 V AC.
£36,171.42
The ABB 1SDA056909R1 is a high-performance SACE Emax E4V 3200 air circuit breaker (ACB) moving part designed for protection and switching in demanding high-current low-voltage electrical distribution systems. Part of the ABB New Emax / SACE Emax range, this four-pole withdrawable circuit-breaker moving part combines a 3200 A rated current with the advanced PR122/P-LSIG electronic overcurrent release.
The PR122/P-LSIG electronic trip unit provides comprehensive LSIG protection, combining long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. This combination helps safeguard conductors, busbars, switchgear and connected equipment against a wide range of electrical fault conditions while supporting coordinated protection in sophisticated power-distribution systems.
With a rated uninterrupted current of 3200 A, a four-pole withdrawable configuration and rated operational voltage of 690 V AC, the 1SDA056909R1 is designed as the moving part of a compatible ABB SACE Emax withdrawable circuit-breaker assembly. The E4V performance level provides rated ultimate and service short-circuit breaking capacities of 150 kA at 400 V AC, 130 kA at 500 V AC and 100 kA at 690 V AC.
Air circuit breakers such as the ABB SACE Emax E4V provide switching and protection for high-current low-voltage distribution networks. The electronic trip unit monitors electrical conditions and initiates circuit interruption when configured protection thresholds are exceeded, helping protect switchgear, cables, busbars and connected equipment against potentially damaging overload, short-circuit and ground-fault conditions.
The PR122/P-LSIG release combines long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. Together with the E4V circuit breaker's 3200 A current rating, 150 kA breaking capacity at 400 V AC and four-pole withdrawable construction, this makes the 1SDA056909R1 particularly suitable for critical main distribution and industrial switchgear installations requiring comprehensive protection, high fault-current performance and convenient serviceability.
| Series | SACE Emax / New Emax |
|---|---|
| ABB order code | 1SDA056909R1 |
| Product type | Air circuit breaker moving part |
| Product group | 310513-New Emax |
| Frame / performance level | E4V |
| Rated current (In) | 3200 A |
| Rated operational current (Ie) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Rated operational voltage | 690 V AC |
| Rated voltage (Ur) | 690 V |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–440 V AC | 150 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 660–690 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 220–440 V AC | 150 kA |
| Rated service short-circuit breaking capacity (Ics) at 500 V AC | 130 kA |
| Rated service short-circuit breaking capacity (Ics) at 660–690 V AC | 100 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Number of poles | 4 |
| Current type | AC |
| Protection release | PR122/P-LSIG R3200 |
| Release type | Electronic |
| Protection functions | L, S, I and G |
| Ground-fault protection | Integrated |
| Short-circuit performance level | V |
| Installation version | Withdrawable |
| Component type | Withdrawable circuit-breaker moving part |
| Terminal connection type | Withdrawable circuit breaker |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Power loss | 425 W |
| Electrical durability | 7000 cycles at ≤440 V AC; 7000 cycles at 500–690 V AC |
| Mechanical durability | 15000 cycles |
| Product net dimensions (W × H × D) | 684 × 461 × 396.5 mm |
| Product net weight | 96 kg |
| EAN | 8015644582494 |
| HS code | 85362090 |
| Standards | IEC |
The ABB 1SDA056909R1 is a 3200 A four-pole air circuit breaker moving part designed for switching and comprehensive protection in high-current low-voltage electrical distribution systems, particularly where very high short-circuit performance is required.
The circuit-breaker moving part is fitted with an ABB PR122/P-LSIG R3200 electronic overcurrent release, providing long-time, short-time, instantaneous and ground-fault protection.
LSIG refers to long-time (L), short-time (S), instantaneous (I) and ground-fault (G) protection. These functions provide comprehensive protection against sustained overloads, short circuits and earth-fault conditions.
The E4V 3200 provides rated ultimate and service short-circuit breaking capacities of 150 kA at 400 V AC, 130 kA at 500 V AC and 100 kA at 690 V AC.
The 1SDA056909R1 is a withdrawable four-pole circuit-breaker moving part designed for use within a compatible ABB SACE Emax withdrawable circuit-breaker assembly.
ABB SACE Emax E4V air circuit breakers are engineered for demanding low-voltage power distribution applications, combining high current-carrying capability, advanced electronic LSIG protection, very high short-circuit performance and withdrawable construction for industrial, commercial and infrastructure electrical systems.