ABB 1SDA056906R1 E4V3200 is a 3200 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LSIG electronic trip unit providing long-time, short-time, instantaneous and ground-fault protection for demanding high-current low-voltage power distribution systems.
£36,017.06
The ABB 1SDA056906R1 is a high-performance SACE Emax E4V air circuit breaker moving part designed for switching and comprehensive protection in high-current low-voltage electrical distribution systems. Identified as E4V3200 PR121/P-LSIG, this four-pole withdrawable circuit breaker combines a 3200 A rated current with ABB's PR121/P-LSIG R3200 electronic overcurrent release.
As part of the ABB SACE Emax / New Emax range, the E4V3200 is engineered for installations with very high prospective fault currents. The V performance level provides a short-circuit breaking capacity of 150 kA at 415 V AC, while its rated short-time withstand current reaches 100 kA for 1 s. Its withdrawable moving-part construction enables the circuit breaker to be disconnected from the corresponding fixed part for inspection, servicing or replacement.
The integrated PR121/P-LSIG R3200 electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection. With a 3200 A rated uninterrupted current and four-pole configuration, the 1SDA056906R1 is well suited to critical main incoming, feeder and distribution protection duties requiring very high breaking capacity, ground-fault protection and serviceable withdrawable construction.
The ABB E4V3200 is designed for substantial low-voltage distribution systems where very high prospective fault currents demand robust interruption capability. Its V performance level provides 150 kA short-circuit breaking capacity at 415 V AC, while the 100 kA rated short-time withstand current for 1 s supports demanding high-current distribution applications.
The PR121/P-LSIG electronic release combines long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. This comprehensive LSIG arrangement helps protect conductors, busbars, switchgear and connected equipment against multiple fault conditions. Combined with its four-pole configuration and withdrawable moving-part construction, the 1SDA056906R1 provides a practical solution for critical switchboards where protection performance and maintainability are important requirements.
| Series | SACE Emax / New Emax |
|---|---|
| Product group | 310513-New Emax |
| Extended product type | E4V3200PR121/P-LSIGIn=3200A4pWMP |
| ABB order code | 1SDA056906R1 |
| Product type | Air circuit breaker moving part |
| Frame | E4 |
| Short-circuit performance level | V |
| Rated current (In) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Number of poles | 4 |
| Trip unit | PR121/P-LSIG |
| Trip unit rating | R3200 |
| Trip unit type | Electronic |
| Protection functions | L, S, I and G |
| Long-time overload protection | Yes |
| Short-time short-circuit protection | Yes |
| Instantaneous short-circuit protection | Yes |
| Ground-fault protection | Yes |
| Short-circuit breaking capacity at 415 V AC | 150 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Installation type | Withdrawable |
| Component type | Moving part (MP) |
| Version | W |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Net weight | 116 kg |
| EAN | 8015644582463 |
| Customs tariff number | 85362090 |
The ABB 1SDA056906R1 is a 3200 A four-pole withdrawable air circuit breaker moving part used for switching and protecting high-current low-voltage electrical distribution systems, particularly where very high short-circuit breaking capacity is required.
This circuit breaker is fitted with the ABB PR121/P-LSIG R3200 electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.
LSIG denotes long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection, providing comprehensive protection against multiple electrical fault conditions.
The E4V3200 has a short-circuit breaking capacity of 150 kA at 415 V AC and a rated short-time withstand current of 100 kA for 1 s, making it suitable for systems with very high prospective fault currents.
Yes. The 1SDA056906R1 is a withdrawable four-pole SACE Emax circuit breaker moving part designed for use with the corresponding fixed part, supporting convenient inspection, servicing and replacement.
ABB SACE Emax air circuit breakers are designed for demanding low-voltage power distribution applications, combining very high breaking performance, comprehensive electronic protection and serviceable withdrawable construction for dependable high-current electrical system protection.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.