1SDA056896R1 ABB E4V 3200 PR121/P-LI 3200A 3P Withdrawable Air Circuit Breaker Moving Part

1SDA056896R1 ABB E4V 3200 PR121/P-LI 3200A 3P Withdrawable Air Circuit Breaker Moving Part

ABB 1SDA056896R1 E4V 3200 three-pole withdrawable SACE Emax air circuit breaker moving part rated at 3200 A with a PR121/P-LI R3200 electronic overcurrent release providing LI protection.

SKU: 1SDA056896R1MPN: 1SDA056896R1
Price
List Price £38,827.44 ex VAT
Your Price (ex VAT) Save 25%
£29,120.58 25% OFF
You save £9,706.86 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £29,120.58
Trade pricing is personalised to your account

Manufacturer Lead Time

£29,120.58

Why Choose the ABB E4V 3200 PR121/P-LI 3200A 3P Withdrawable Air Circuit Breaker?

The ABB E4V 3200 PR121/P-LI, order code 1SDA056896R1, is a high-performance three-pole withdrawable air circuit breaker moving part designed for protection and switching in high-current low-voltage electrical distribution systems. Part of the proven ABB SACE Emax E4 series, it combines a rated uninterrupted current of 3200 A with the PR121/P-LI electronic overcurrent release.

The E4V performance level is engineered for electrical installations with high prospective short-circuit currents. Its PR121/P-LI electronic release provides long-time overload and instantaneous short-circuit protection, helping safeguard conductors, switchboards and connected equipment while providing dependable fault interruption in demanding industrial and infrastructure applications.

This configuration is the moving part of a withdrawable circuit breaker, allowing it to be disconnected and removed from the compatible fixed part for maintenance, inspection or replacement. With a 3200 A current rating, three-pole construction and rated operational voltage up to 690 V AC, the E4V 3200 is suitable for major switchboards, transformer distribution systems and high-capacity industrial power networks.

Key Advantages

  • High-capacity 3200 A air circuit breaker moving part for demanding low-voltage distribution systems.
  • Three-pole configuration for three-phase power distribution applications.
  • PR121/P-LI electronic overcurrent release with R3200 rating.
  • Provides long-time overload and instantaneous short-circuit protection.
  • Exceptional 150 kA short-circuit breaking capacity at 400 V AC.
  • Withdrawable construction supports efficient maintenance, inspection and replacement.
  • ABB SACE Emax platform engineered for dependable protection of critical electrical distribution systems.

Key Features

  • ABB SACE Emax E4V air circuit breaker moving part.
  • 3200 A rated uninterrupted current.
  • 3-pole configuration.
  • PR121/P-LI R3200 electronic overcurrent release.
  • Withdrawable version for use with a compatible fixed part.
  • Rated operational voltage up to 690 V AC.
  • Rated insulation voltage of 1000 V.
  • Rated impulse withstand voltage of 12 kV.
  • V short-circuit performance level.
  • Fitted with four auxiliary contacts for circuit-breaker open/closed position indication.
  • Designed to IEC requirements for low-voltage circuit breakers.

High-Performance Protection for Critical Power Distribution

Air circuit breakers such as the ABB E4V 3200 provide primary switching and protection for high-current low-voltage electrical systems. The V performance level is intended for installations requiring particularly high fault-interruption capability, making this 3200 A Emax breaker suitable for substantial industrial and infrastructure distribution networks.

The PR121/P-LI electronic release provides long-time overload and instantaneous short-circuit protection. Combined with the withdrawable Emax architecture, this provides reliable circuit protection while allowing the breaker moving part to be isolated and removed from compatible switchgear for servicing, inspection or replacement.

Typical Applications

  • Main incoming protection in high-capacity low-voltage switchboards.
  • Industrial power distribution and process plants.
  • Transformer secondary and distribution protection.
  • Generator and utility distribution systems.
  • Data centres and critical infrastructure power systems.
  • Large commercial and manufacturing facilities.
  • High-current feeder and distribution protection.

Technical Specifications

Product family SACE Emax
Series / frame E4V
ABB order code 1SDA056896R1
EAN 8015644582364
Product type Air circuit breaker moving part
Rated uninterrupted current (Iu) 3200 A
Rated operational current (Ie) 3200 A
Number of poles 3
Version Withdrawable (W / moving part)
Trip unit PR121/P-LI electronic release
Rating plug R3200
Protection functions Long-time and instantaneous (LI)
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated service short-circuit breaking capacity (Ics) at 220–440 V AC 150 kA
Rated service short-circuit breaking capacity (Ics) at 500 V AC 130 kA
Rated service short-circuit breaking capacity (Ics) at 660–690 V AC 100 kA
Current type AC
Release type Electronic
Short-circuit performance level V
Standard IEC
Power loss 425 W
Mechanical durability 15,000 operating cycles
Electrical durability at ≤440 V 7,000 operating cycles
Electrical durability at 500–690 V 7,000 operating cycles
Product dimensions (W × H × D) 594 × 461 × 396.5 mm
Product net weight 85 kg
Auxiliary contacts 4
Position indication Circuit breaker open / closed

Frequently Asked Questions

What is the ABB 1SDA056896R1?

The ABB 1SDA056896R1 is the moving part of an E4V 3200 three-pole withdrawable SACE Emax air circuit breaker, rated at 3200 A and equipped with a PR121/P-LI R3200 electronic overcurrent release.

What protection functions does the PR121/P-LI release provide?

The PR121/P-LI provides long-time overload and instantaneous short-circuit protection functions.

What is the breaking capacity of the ABB E4V 3200?

The E4V 3200 provides a rated service short-circuit breaking capacity of 150 kA at 220–440 V AC, 130 kA at 500 V AC and 100 kA at 660–690 V AC.

Is the ABB 1SDA056896R1 fixed or withdrawable?

This product is the moving part of a withdrawable circuit breaker and is designed for use with the appropriate compatible fixed part in an ABB SACE Emax switchgear assembly.

Where is the E4V 3200 PR121/P-LI typically used?

It is designed for high-current low-voltage distribution applications including industrial switchboards, transformer distribution systems, power centres, critical infrastructure and other installations requiring high short-circuit breaking performance.

Trusted Protection for Critical Power Systems

ABB SACE Emax air circuit breakers provide high-performance switching and protection for demanding low-voltage power distribution systems, combining high current capacity, electronic protection and withdrawable construction for maintainable switchgear installations.