1SDA056860R1 ABB E4H4000 PR122/P-LSI 4000 A 4-Pole Fixed Air Circuit Breaker

1SDA056860R1 ABB E4H4000 PR122/P-LSI 4000 A 4-Pole Fixed Air Circuit Breaker

ABB 1SDA056860R1 E4H4000 is a 4000 A four-pole fixed SACE Emax air circuit breaker with rear horizontal terminals and a PR122/P-LSI R4000 electronic release providing long-time, short-time and instantaneous overcurrent protection.

SKU: 1SDA056860R1MPN: 1SDA056860R1
Price
List Price £44,931.09 ex VAT
Your Price (ex VAT) Save 25%
£33,698.32 25% OFF
You save £11,232.77 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £33,698.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£33,698.32

Why Choose the ABB E4H4000 PR122/P-LSI Air Circuit Breaker?

The ABB E4H4000 PR122/P-LSI, order code 1SDA056860R1, is a high-performance SACE Emax air circuit breaker designed for switching and overcurrent protection in demanding low-voltage power-distribution systems. Part of the ABB SACE Emax E4 series, this four-pole fixed circuit breaker combines a 4000 A rated uninterrupted current with the PR122/P-LSI R4000 electronic overcurrent release.

The PR122/P-LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. These LSI functions help protect high-current conductors, busbars, switchboards and connected equipment against sustained overloads and short circuits while supporting selective protection and coordinated fault clearing across complex power-distribution networks.

This configuration is a four-pole fixed circuit breaker equipped with rear horizontal terminals. Its E4H high short-circuit performance level provides an ultimate breaking capacity of 100 kA at 400 V AC and 85 kA at 690 V AC, making it suitable for installations with substantial prospective fault currents.

Key Advantages

  • High-current 4000 A SACE Emax air circuit breaker for major low-voltage distribution systems.
  • PR122/P-LSI R4000 electronic release provides comprehensive LSI overcurrent protection.
  • Long-time, short-time and instantaneous protection supports selective and coordinated fault clearing.
  • Four-pole configuration supports three-phase systems requiring neutral switching.
  • Fixed construction with rear horizontal terminals provides robust permanent switchboard integration.
  • 100 kA ultimate short-circuit breaking capacity at 400 V AC suits demanding high-fault-level installations.
  • 100 kA short-time withstand current for 1 s supports selective power-distribution designs.
  • Four auxiliary contacts and open/closed indication support switchboard signalling and control.

Key Features

  • ABB SACE Emax E4H4000 air circuit breaker.
  • 4000 A rated uninterrupted current.
  • Four-pole fixed configuration.
  • PR122/P-LSI R4000 electronic overcurrent release.
  • L protection: long-time overload protection.
  • S protection: short-time short-circuit protection.
  • I protection: instantaneous short-circuit protection.
  • H short-circuit performance level.
  • 100 kA Icu at 400 V AC.
  • 85 kA Icu at 690 V AC.
  • 100 kA Icw for 1 s.
  • 75 kA Icw for 3 s.
  • Rear horizontal terminal arrangement.
  • Four auxiliary contacts for signalling and control.
  • Integrated circuit-breaker open/closed position indication.

Reliable LSI Protection for High-Fault-Level Power Distribution

The ABB SACE Emax E4H4000 is engineered for switching and protection at main incomer, bus-coupler and high-current feeder levels within substantial low-voltage distribution systems. Its PR122/P-LSI electronic release combines long-time protection against sustained overloads, short-time protection for coordinated fault clearing and instantaneous intervention against severe short-circuit currents.

The combination of a 4000 A current rating, four-pole construction and 100 kA short-circuit breaking capacity at 400 V AC makes the 1SDA056860R1 particularly suitable for installations with high prospective fault currents. Its fixed construction and rear horizontal terminals provide permanent switchboard integration, while the auxiliary contacts provide useful status information for associated monitoring, signalling and control systems.

Typical Applications

  • Main low-voltage distribution switchboards.
  • High-fault-level industrial power-distribution systems.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical installations.
  • Transformer secondary and main incomer protection.
  • High-current feeder protection.
  • Bus-coupler and power-distribution assemblies.

Technical Specifications

Product group New Emax
Series SACE Emax E4
ABB order code 1SDA056860R1
Extended product type E4H4000PR122/P-LSIIn=4000A4pFHR
Catalog description E4H 4000 PR122/P-LSI In=4000A 4p F HR
Product type Air circuit breaker
Frame E4
Short-circuit performance level H
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Number of poles 4P
Current type AC
Release PR122/P-LSI R4000
Release type Electronic overcurrent release
Protection functions LSI — long-time, short-time and instantaneous
Long-time overload protection Yes
Short-time short-circuit protection Yes
Instantaneous short-circuit protection Yes
Integrated earth-fault protection No
Version Fixed
Terminal connection Rear horizontal
Rated ultimate short-circuit breaking capacity (Icu) at 220 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 230 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 660 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Electrical durability at Ue ≤ 440 V 5000 cycles
Electrical durability at Ue 500–690 V 4000 cycles
Electrical operating frequency 10 cycles per hour
Mechanical durability 15,000 cycles
Auxiliary contacts 4
Position indication Open / closed
Product width 656 mm
Product height 418 mm
Product depth 302 mm
Product net weight 92 kg
EAN 8015644582005
HS code 85362090
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA056860R1 used for?

The ABB 1SDA056860R1 is a 4000 A four-pole SACE Emax air circuit breaker designed for switching and LSI overcurrent protection in demanding high-current, high-fault-level low-voltage power-distribution systems.

What protection release is fitted to the ABB E4H4000?

This circuit breaker is fitted with the ABB PR122/P-LSI R4000 electronic overcurrent release, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the rated current of the ABB E4H4000 PR122/P-LSI?

The ABB E4H4000 PR122/P-LSI has a rated uninterrupted current of 4000 A.

Is the ABB 1SDA056860R1 fixed or withdrawable?

The 1SDA056860R1 is a four-pole fixed circuit breaker equipped with rear horizontal terminals for permanent installation within a compatible low-voltage switchboard.

What does LSI mean on the PR122/P release?

LSI denotes long-time overload, short-time short-circuit and instantaneous short-circuit protection. This release configuration does not incorporate the G earth-fault protection function found on PR122/P-LSIG versions.

Trusted Protection for Industrial Power Systems

ABB SACE Emax air circuit breakers provide dependable switching and electronic protection for demanding low-voltage distribution systems, combining high current capability, high short-circuit performance and configurable electronic protection for critical electrical infrastructure.