Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056840R1 E4H3200 is a 3200 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LI electronic trip unit providing long-time overload and instantaneous short-circuit protection for high-current low-voltage power distribution systems.
£32,079.86
The ABB 1SDA056840R1 is a high-performance SACE Emax E4H air circuit breaker moving part designed for switching and protection in high-current low-voltage electrical distribution systems. Identified as E4H3200 PR121/P-LI, this four-pole withdrawable circuit breaker combines a 3200 A rated current with ABB's PR121/P-LI electronic overcurrent release for dependable overload and instantaneous short-circuit protection.
As part of the ABB SACE Emax / New Emax range, the E4H3200 is engineered for demanding industrial, commercial and infrastructure power distribution applications. Its H short-circuit performance level provides an ultimate short-circuit breaking capacity of 100 kA at 400 V AC and 85 kA at 690 V AC. Its withdrawable moving-part construction supports convenient inspection, servicing and replacement when installed with the corresponding fixed part.
The integrated PR121/P-LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. With a rated operational voltage of up to 690 V AC, four-pole configuration and 3200 A rated uninterrupted current, the 1SDA056840R1 is well suited to main incoming and distribution protection duties where high breaking capacity, four-pole switching and withdrawable construction are required.
Air circuit breakers such as the ABB E4H3200 provide switching and protection for high-current low-voltage distribution systems. The E4H performance level is designed for installations with substantial prospective fault currents, offering an ultimate short-circuit breaking capacity of 100 kA through the 400–500 V AC range and 85 kA at 660–690 V AC.
The PR121/P-LI electronic release provides long-time overload and instantaneous short-circuit protection, while the four-pole construction enables switching across three-phase four-wire systems. Combined with high breaking performance and withdrawable moving-part construction, the 1SDA056840R1 is suitable for major switchboards and industrial distribution systems where dependable protection and straightforward circuit breaker maintenance are required.
| Series | SACE Emax / New Emax |
|---|---|
| Product group | 310513-New Emax |
| ABB order code | 1SDA056840R1 |
| Product type | Air circuit breaker moving part |
| Frame | E4 |
| Short-circuit performance level | H |
| Rated current (In) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 4 |
| Current type | AC |
| Trip unit | PR121/P-LI |
| Trip unit type | Electronic |
| Protection functions | L and I |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 660 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Installation type | Withdrawable |
| Component type | Moving part (MP) |
| Version | W |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Standard | IEC |
| EAN | 8015644581800 |
The ABB 1SDA056840R1 is a 3200 A four-pole withdrawable air circuit breaker moving part used for switching and protecting high-current low-voltage electrical distribution systems.
This circuit breaker is fitted with the ABB PR121/P-LI electronic trip unit, providing long-time overload and instantaneous short-circuit protection.
The circuit breaker has a rated uninterrupted current of 3200 A.
The E4H3200 has an ultimate short-circuit breaking capacity (Icu) of 100 kA at 400 V AC and 85 kA at 690 V AC, making it suitable for high-fault-level low-voltage distribution systems.
Yes. The 1SDA056840R1 is a withdrawable four-pole SACE Emax circuit breaker moving part designed for use with the corresponding fixed part or cradle, supporting convenient inspection, servicing and maintenance.
ABB SACE Emax air circuit breakers are designed for demanding low-voltage power distribution applications, combining high breaking performance, electronic protection and serviceable withdrawable construction for dependable high-current electrical system protection.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.