1SDA056832R1 ABB E4H 3200 PR121/P-LI 3200 A 3-Pole Withdrawable Air Circuit Breaker Moving Part

1SDA056832R1 ABB E4H 3200 PR121/P-LI 3200 A 3-Pole Withdrawable Air Circuit Breaker Moving Part

ABB 1SDA056832R1 is a three-pole 3200 A SACE Emax E4H withdrawable air circuit breaker moving part with PR121/P-LI electronic protection and a 100 kA ultimate short-circuit breaking capacity at 400 V AC.

SKU: 1SDA056832R1MPN: 1SDA056832R1
Price
List Price £34,129.02 ex VAT
Your Price (ex VAT) Save 25%
£25,596.77 25% OFF
You save £8,532.26 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £25,596.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£25,596.77

Why Choose the ABB 1SDA056832R1 E4H 3200 Air Circuit Breaker?

The ABB 1SDA056832R1 is a high-performance SACE Emax E4H 3200 air circuit breaker (ACB) moving part designed for protection and switching in demanding high-current low-voltage electrical distribution systems. Part of the ABB New Emax / SACE Emax range, this three-pole withdrawable circuit-breaker moving part combines a 3200 A rated current with the PR121/P-LI electronic overcurrent release.

The PR121/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection, helping safeguard conductors, busbars, switchgear and connected equipment against damaging overcurrent conditions. The E4H high-performance configuration is engineered for installations with substantial prospective fault currents, while the withdrawable design supports convenient servicing and maintenance within compatible switchgear assemblies.

With a rated uninterrupted current of 3200 A, a three-pole withdrawable configuration and rated operational voltage up to 690 V AC, the 1SDA056832R1 is suited to high-capacity industrial and commercial power distribution. The E4H performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 400 V AC and 85 kA at 690 V AC.

Key Advantages

  • High-capacity 3200 A air circuit breaker moving part for low-voltage power distribution.
  • Withdrawable three-pole design supports maintainable switchboard installations.
  • PR121/P-LI electronic protection release provides overload and instantaneous short-circuit protection.
  • E4H high-breaking-capacity performance level for systems with substantial prospective fault currents.
  • 100 kA ultimate short-circuit breaking capacity at 400 V AC.
  • 85 kA ultimate short-circuit breaking capacity at 690 V AC.
  • 100 kA short-time withstand current for 1 s supports demanding distribution applications.
  • Four auxiliary contacts provide circuit-breaker open/closed status indication.

Key Features

  • ABB SACE Emax E4H 3200 series.
  • 3200 A rated uninterrupted current.
  • Three-pole circuit-breaker configuration.
  • Withdrawable moving part construction.
  • PR121/P-LI R3200 electronic overcurrent release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • 100 kA Icu at 220–500 V AC.
  • 85 kA Icu at 660–690 V AC.
  • 100 kA short-time withstand current for 1 s.
  • 75 kA short-time withstand current for 3 s.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.

High-Performance Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax E4H provide switching and protection for high-current low-voltage distribution networks. The electronic trip unit monitors electrical conditions and initiates circuit interruption when configured protection thresholds are exceeded, helping protect switchgear, cables, busbars and connected equipment from damaging overload and short-circuit currents.

The PR121/P-LI release combines long-time overload protection with instantaneous short-circuit protection. Together with the E4H circuit breaker's high fault-breaking and short-time withstand capabilities, the 1SDA056832R1 is well suited to demanding main distribution and industrial switchgear applications where high current capacity and maintainable withdrawable construction are required.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical installations.
  • Transformer secondary circuit protection.
  • Main incomer and high-current feeder protection.
  • Withdrawable switchgear requiring serviceable circuit-breaker assemblies.
  • Electrical systems with high prospective short-circuit currents.

Technical Specifications

Series SACE Emax / New Emax
ABB order code 1SDA056832R1
Product type Air circuit breaker moving part
Product group 310513-New Emax
Frame / performance level E4H
Rated current (In) 3200 A
Rated uninterrupted current (Iu) 3200 A
Rated operational voltage up to 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 220 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 230 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 660 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Number of poles 3
Current type AC
Protection release PR121/P-LI R3200
Release type Electronic
Protection functions L and I
Short-circuit performance level H
Installation version Withdrawable
Component type Withdrawable circuit-breaker moving part
Auxiliary contacts 4
Position indication Circuit breaker open / closed
EAN 8015644581725
Standards IEC

Frequently Asked Questions

What is the ABB 1SDA056832R1 used for?

The ABB 1SDA056832R1 is a 3200 A three-pole air circuit breaker moving part designed for switching and protection in high-current low-voltage electrical distribution systems.

What protection release is fitted to the ABB 1SDA056832R1?

The circuit breaker is fitted with an ABB PR121/P-LI R3200 electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection.

What is the short-circuit breaking capacity of the ABB E4H 3200?

The E4H 3200 has a rated ultimate short-circuit breaking capacity of 100 kA at 400 V AC and 85 kA at 690 V AC.

Is the ABB 1SDA056832R1 fixed or withdrawable?

The 1SDA056832R1 is a withdrawable circuit-breaker moving part designed for use within a compatible ABB SACE Emax withdrawable circuit-breaker assembly.

How many poles does the ABB 1SDA056832R1 have?

The 1SDA056832R1 is a three-pole circuit-breaker moving part with a rated current of 3200 A.

Trusted High-Current Circuit Protection

ABB SACE Emax E4H air circuit breakers are engineered for demanding low-voltage power distribution applications, combining high current-carrying capability, electronic protection, high short-circuit performance and withdrawable switchgear options for industrial, commercial and infrastructure electrical systems.