ABB 1SDA056826R1 E4H3200 is a 3200 A four-pole fixed SACE Emax air circuit breaker with rear flat horizontal terminals and a PR121/P-LSIG R3200 electronic release providing long-time, short-time, instantaneous and earth-fault protection.
£28,304.78
The ABB E4H3200 PR121/P-LSIG, order code 1SDA056826R1, is a high-performance SACE Emax air circuit breaker designed for switching and comprehensive protection in demanding low-voltage power-distribution systems. Part of the ABB SACE Emax E4 series, this four-pole fixed circuit breaker combines a 3200 A rated uninterrupted current with the PR121/P-LSIG R3200 electronic overcurrent release.
The PR121/P-LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. These LSIG functions provide comprehensive protection against sustained overloads, short circuits and earth faults, making the breaker well suited to high-capacity industrial and infrastructure distribution networks where selective and dependable circuit protection is required.
This configuration is a four-pole fixed circuit breaker with rear flat horizontal terminals. The E4H performance level provides an ultimate short-circuit breaking capacity of 100 kA at 400 V AC, while the breaker is supplied with four auxiliary contacts and open/closed position indication for integration into switchboard monitoring and control systems.
The ABB SACE Emax E4H3200 is engineered for switching and protection at main incomer, bus-coupler and high-current feeder levels within substantial low-voltage distribution systems. Its PR121/P-LSIG electronic release combines long-time protection against sustained overloads, short-time protection for coordinated fault clearing, instantaneous intervention against severe short circuits and earth-fault protection.
The combination of a 3200 A current rating, four-pole construction and 100 kA short-circuit breaking capacity at 400 V AC makes the 1SDA056826R1 particularly suitable for installations with high prospective fault currents. Its fixed construction and rear horizontal terminals provide robust permanent switchboard integration, while the auxiliary contacts provide useful status information for associated monitoring, signalling and control systems.
| Product group | New Emax |
|---|---|
| Series | SACE Emax E4 |
| ABB order code | 1SDA056826R1 |
| Extended product type | E4H3200PR121/P-LSIGIn=3200A4pFHR |
| Product type | Air circuit breaker |
| Frame | E4 |
| Short-circuit performance level | H |
| Rated current (In) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Number of poles | 4P |
| Release | PR121/P-LSIG R3200 |
| Release type | Electronic |
| Protection functions | LSIG — long-time, short-time, instantaneous and earth-fault |
| Long-time overload protection | Yes |
| Short-time short-circuit protection | Yes |
| Instantaneous short-circuit protection | Yes |
| Earth-fault protection | Yes |
| Version | Fixed |
| Terminal connection | Rear flat horizontal |
| Rated ultimate short-circuit breaking capacity (Icu) at 220 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 230 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 660 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| EAN | 8015644581664 |
| Standard | IEC |
The ABB 1SDA056826R1 is a 3200 A four-pole SACE Emax air circuit breaker designed for switching and comprehensive overcurrent and earth-fault protection in high-current, high-fault-level low-voltage power-distribution systems.
This circuit breaker is fitted with the ABB PR121/P-LSIG R3200 electronic overcurrent release, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.
The circuit breaker has a rated uninterrupted current of 3200 A.
The 1SDA056826R1 is a four-pole fixed circuit breaker with rear flat horizontal terminals for permanent installation within a compatible low-voltage switchboard.
LSIG denotes long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, providing comprehensive electronic protection against a broad range of electrical fault conditions.
ABB SACE Emax air circuit breakers provide dependable switching and electronic protection for demanding low-voltage distribution systems, combining high current capability, high short-circuit performance and comprehensive LSIG protection for critical electrical infrastructure.