1SDA056811R1 ABB E4S4000 PR122/P-LI 4000 A 4-Pole Withdrawable Air Circuit Breaker

1SDA056811R1 ABB E4S4000 PR122/P-LI 4000 A 4-Pole Withdrawable Air Circuit Breaker

ABB 1SDA056811R1 E4S4000 is a 4000 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LI R4000 electronic release providing long-time overload and instantaneous short-circuit protection.

SKU: 1SDA056811R1MPN: 1SDA056811R1
Price
List Price £50,625.97 ex VAT
Your Price (ex VAT) Save 25%
£37,969.48 25% OFF
You save £12,656.49 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £37,969.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£37,969.48

Why Choose the ABB E4S4000 PR122/P-LI Air Circuit Breaker?

The ABB E4S4000 PR122/P-LI, order code 1SDA056811R1, is a high-current SACE Emax air circuit breaker moving part designed for switching and overcurrent protection in demanding low-voltage power-distribution systems. Part of the ABB SACE Emax E4 series, this four-pole withdrawable configuration combines a 4000 A rated uninterrupted current with the PR122/P-LI R4000 electronic overcurrent release.

The PR122/P-LI release provides long-time overload and instantaneous short-circuit protection. These LI functions protect high-current conductors, switchboards and connected equipment against sustained overloads and severe short-circuit faults, making the breaker suitable for major industrial, commercial and infrastructure power-distribution networks.

This model is the four-pole withdrawable moving part of the E4S4000 circuit breaker and is designed for use with the corresponding ABB SACE Emax fixed part. It combines a 75 kA ultimate short-circuit breaking capacity at 400 V AC with four auxiliary contacts and open/closed position indication, providing robust protection together with service-friendly withdrawable construction.

Key Advantages

  • High-current 4000 A SACE Emax air circuit breaker moving part.
  • PR122/P-LI R4000 electronic release provides long-time overload and instantaneous short-circuit protection.
  • Four-pole configuration supports three-phase distribution systems requiring neutral switching.
  • Withdrawable construction facilitates inspection, maintenance and circuit-breaker servicing.
  • 75 kA ultimate and service short-circuit breaking capacity across the specified AC voltage range.
  • 75 kA short-time withstand current for both 1 s and 3 s.
  • Four auxiliary contacts and open/closed position indication support switchboard signalling and control.

Key Features

  • ABB SACE Emax E4S4000 air circuit breaker moving part.
  • 4000 A rated uninterrupted current.
  • Four-pole withdrawable version.
  • PR122/P-LI R4000 electronic overcurrent release.
  • L protection: long-time overload protection.
  • I protection: instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 75 kA rated ultimate short-circuit breaking capacity.
  • 75 kA rated service short-circuit breaking capacity.
  • Four auxiliary contacts for signalling and control.
  • Integrated circuit-breaker open/closed position indication.

Reliable LI Protection for 4000 A Power Distribution

The ABB SACE Emax E4S4000 is designed for switching and protection at main incomer and high-current feeder levels within substantial low-voltage distribution systems. Its PR122/P-LI electronic release provides long-time protection against sustained overload conditions together with instantaneous intervention against severe short-circuit currents, helping protect conductors, switchboards and connected electrical equipment.

The combination of a 4000 A current rating, four-pole construction, 75 kA short-circuit capability and withdrawable design makes the 1SDA056811R1 suitable for critical high-capacity switchboards where electrical performance and serviceability are both important. When installed with the corresponding fixed part, the moving circuit breaker can be withdrawn for inspection and maintenance, supporting efficient servicing of major power-distribution assemblies.

Typical Applications

  • Main low-voltage distribution switchboards.
  • High-current industrial power-distribution systems.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical installations.
  • Transformer secondary and main incomer protection.
  • High-current feeder protection.
  • Withdrawable switchgear and power-distribution assemblies.

Technical Specifications

Product group New Emax
Series SACE Emax E4
ABB order code 1SDA056811R1
Extended product type E4S4000PR122/P-LIIn=4000A4pWMP
Product type Air circuit breaker moving part
Frame E4
Short-circuit performance level S
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Rated operational current (Ie) 4000 A
Number of poles 4P
Current type AC
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Release PR122/P-LI R4000
Release type Electronic
Protection functions LI — long-time and instantaneous
Overload release adjustment range 1600–4000 A
Instantaneous short-circuit release adjustment range 6000–60,000 A
Version Withdrawable moving part
Rated ultimate short-circuit breaking capacity (Icu) at 220–690 V AC 75 kA
Rated service short-circuit breaking capacity (Ics) at 220–690 V AC 75 kA
Rated short-time withstand current (Icw), 1 s 75 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Auxiliary contacts 4
Position indication Open / closed
Product net weight 116 kg
EAN 8015644581510
HS code 85362090
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA056811R1 used for?

The ABB 1SDA056811R1 is a 4000 A four-pole SACE Emax air circuit breaker moving part designed for switching and overcurrent protection in high-current low-voltage power-distribution systems.

What protection release is fitted to the ABB E4S4000?

This circuit breaker is fitted with the ABB PR122/P-LI R4000 electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection.

What is the rated current of the ABB E4S4000 PR122/P-LI?

The circuit breaker has a rated uninterrupted current of 4000 A and a rated operational voltage of 690 V AC.

Is the ABB 1SDA056811R1 fixed or withdrawable?

The 1SDA056811R1 is a four-pole withdrawable moving part designed for use with the corresponding ABB SACE Emax fixed part.

What does LI mean on the PR122/P release?

LI denotes long-time overload and instantaneous short-circuit protection, providing electronic protection against sustained overcurrents and severe short-circuit faults.

Trusted Protection for Industrial Power Systems

ABB SACE Emax air circuit breakers provide dependable switching and electronic protection for demanding low-voltage distribution systems, combining high current capability, robust short-circuit performance and service-friendly withdrawable construction for critical electrical infrastructure.