Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056811R1 E4S4000 is a 4000 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR122/P-LI R4000 electronic release providing long-time overload and instantaneous short-circuit protection.
£37,969.48
The ABB E4S4000 PR122/P-LI, order code 1SDA056811R1, is a high-current SACE Emax air circuit breaker moving part designed for switching and overcurrent protection in demanding low-voltage power-distribution systems. Part of the ABB SACE Emax E4 series, this four-pole withdrawable configuration combines a 4000 A rated uninterrupted current with the PR122/P-LI R4000 electronic overcurrent release.
The PR122/P-LI release provides long-time overload and instantaneous short-circuit protection. These LI functions protect high-current conductors, switchboards and connected equipment against sustained overloads and severe short-circuit faults, making the breaker suitable for major industrial, commercial and infrastructure power-distribution networks.
This model is the four-pole withdrawable moving part of the E4S4000 circuit breaker and is designed for use with the corresponding ABB SACE Emax fixed part. It combines a 75 kA ultimate short-circuit breaking capacity at 400 V AC with four auxiliary contacts and open/closed position indication, providing robust protection together with service-friendly withdrawable construction.
The ABB SACE Emax E4S4000 is designed for switching and protection at main incomer and high-current feeder levels within substantial low-voltage distribution systems. Its PR122/P-LI electronic release provides long-time protection against sustained overload conditions together with instantaneous intervention against severe short-circuit currents, helping protect conductors, switchboards and connected electrical equipment.
The combination of a 4000 A current rating, four-pole construction, 75 kA short-circuit capability and withdrawable design makes the 1SDA056811R1 suitable for critical high-capacity switchboards where electrical performance and serviceability are both important. When installed with the corresponding fixed part, the moving circuit breaker can be withdrawn for inspection and maintenance, supporting efficient servicing of major power-distribution assemblies.
| Product group | New Emax |
|---|---|
| Series | SACE Emax E4 |
| ABB order code | 1SDA056811R1 |
| Extended product type | E4S4000PR122/P-LIIn=4000A4pWMP |
| Product type | Air circuit breaker moving part |
| Frame | E4 |
| Short-circuit performance level | S |
| Rated current (In) | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated operational current (Ie) | 4000 A |
| Number of poles | 4P |
| Current type | AC |
| Rated operational voltage | 690 V AC |
| Rated voltage (Ur) | 690 V |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Release | PR122/P-LI R4000 |
| Release type | Electronic |
| Protection functions | LI — long-time and instantaneous |
| Overload release adjustment range | 1600–4000 A |
| Instantaneous short-circuit release adjustment range | 6000–60,000 A |
| Version | Withdrawable moving part |
| Rated ultimate short-circuit breaking capacity (Icu) at 220–690 V AC | 75 kA |
| Rated service short-circuit breaking capacity (Ics) at 220–690 V AC | 75 kA |
| Rated short-time withstand current (Icw), 1 s | 75 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Product net weight | 116 kg |
| EAN | 8015644581510 |
| HS code | 85362090 |
| Standard | IEC |
The ABB 1SDA056811R1 is a 4000 A four-pole SACE Emax air circuit breaker moving part designed for switching and overcurrent protection in high-current low-voltage power-distribution systems.
This circuit breaker is fitted with the ABB PR122/P-LI R4000 electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection.
The circuit breaker has a rated uninterrupted current of 4000 A and a rated operational voltage of 690 V AC.
The 1SDA056811R1 is a four-pole withdrawable moving part designed for use with the corresponding ABB SACE Emax fixed part.
LI denotes long-time overload and instantaneous short-circuit protection, providing electronic protection against sustained overcurrents and severe short-circuit faults.
ABB SACE Emax air circuit breakers provide dependable switching and electronic protection for demanding low-voltage distribution systems, combining high current capability, robust short-circuit performance and service-friendly withdrawable construction for critical electrical infrastructure.
We use cookies