1SDA056794R1 ABB E4S4000 PR121/P-LSIG 4000A 4P Air Circuit Breaker

1SDA056794R1 ABB E4S4000 PR121/P-LSIG 4000A 4P Air Circuit Breaker

ABB 1SDA056794R1 E4S4000 PR121/P-LSIG is a 4000 A four-pole fixed SACE Emax air circuit breaker with rear horizontal terminals and a PR121/P-LSIG R4000 electronic release providing long-time, short-time, instantaneous and earth-fault protection.

SKU: 1SDA056794R1MPN: 1SDA056794R1
Price
List Price £39,701.79 ex VAT
Your Price (ex VAT) Save 25%
£29,776.34 25% OFF
You save £9,925.45 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £29,776.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£29,776.34

Why Choose the ABB E4S4000 PR121/P-LSIG 4000A 4P Air Circuit Breaker?

The ABB E4S4000 PR121/P-LSIG, order code 1SDA056794R1, is a high-performance SACE Emax E4S air circuit breaker designed for protection and switching in high-current low-voltage electrical distribution systems. Rated at 4000 A, this four-pole fixed circuit breaker combines the robust ABB SACE Emax platform with a PR121/P-LSIG R4000 electronic overcurrent release.

The PR121/P-LSIG release provides long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection, delivering comprehensive protection against overload, short-circuit and earth-fault conditions. The E4S performance level is engineered for demanding main distribution applications where high continuous current capacity, selective protection and dependable fault interruption are required.

This configuration is supplied as a four-pole fixed circuit breaker with rear horizontal flat terminals. It has a rated operational current of 4000 A, rated operational voltage of 690 V AC and rated ultimate short-circuit breaking capacity of 75 kA across its specified AC voltage range, making it suitable for substantial industrial and infrastructure power-distribution systems.

Key Advantages

  • High-current 4000 A SACE Emax E4S air circuit breaker for demanding low-voltage distribution.
  • Four-pole configuration provides switching and protection across four conductors.
  • PR121/P-LSIG electronic overcurrent release provides L, S, I and G protection functions.
  • Integrated earth-fault protection provides additional protection for electrical distribution systems.
  • Fixed construction for permanent integration into high-capacity switchboards.
  • Rear horizontal flat terminals provide a practical busbar connection arrangement.
  • 75 kA ultimate and service short-circuit breaking capacity across the specified AC voltage range.
  • 75 kA short-time withstand current for both 1 s and 3 s supports robust system coordination.

Key Features

  • ABB SACE Emax E4S series.
  • 4000 A rated current.
  • Four-pole circuit-breaker configuration.
  • PR121/P-LSIG R4000 electronic overcurrent release.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Earth-fault protection (G).
  • Fixed execution with rear horizontal flat terminals.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.

Comprehensive 4000A Protection for High-Capacity Distribution

Air circuit breakers such as the ABB SACE Emax E4S are designed to protect high-capacity low-voltage distribution systems against damaging overload, short-circuit and earth-fault conditions. The PR121/P-LSIG electronic release combines long-time, short-time, instantaneous and earth-fault protection functions, helping safeguard busbars, feeders and connected equipment while supporting coordinated system protection.

The E4S4000 PR121/P-LSIG combines a substantial 4000 A current rating, four-pole construction and fixed rear-connected design with 75 kA short-circuit performance. These characteristics make it particularly suitable for main switchboards and high-capacity power-distribution assemblies where dependable fault interruption and comprehensive electronic protection are essential.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • High-capacity industrial power distribution systems.
  • Main incoming and high-current feeder protection.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry switchgear.
  • Transformer and generator distribution systems.
  • High-current busbar and distribution-board protection.
  • Electrical installations requiring four-pole switching and earth-fault protection.

Technical Specifications

Series SACE Emax E4S
ABB order code 1SDA056794R1
Product group 310513-New Emax
Product type Air circuit breaker
Rated current (In) 4000 A
Rated operational current (Ie) 4000 A
Rated uninterrupted current (Iu) 4000 A
Number of poles 4
Execution Fixed
Main terminal arrangement Rear flat horizontal
Protection release PR121/P-LSIG R4000
Release technology Electronic
Protection functions Long-time (L), short-time (S), instantaneous (I) and earth-fault (G)
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 75 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 75 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 75 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 75 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 75 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 75 kA
Rated short-time withstand current (Icw), 1 s 75 kA
Rated short-time withstand current (Icw), 3 s 75 kA
Short-circuit performance level S
Overload release adjustment range 1250–4000 A
Mechanical endurance 15000 cycles
Electrical endurance at ≤440 V AC 5000 cycles
Electrical endurance at 500–690 V AC 4000 cycles
Power loss 360 W
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Standard IEC
EAN 8015644581343
HS code 85362090

Frequently Asked Questions

What is the ABB 1SDA056794R1?

The ABB 1SDA056794R1 is an E4S4000 SACE Emax air circuit breaker rated at 4000 A, with four poles, fixed construction, rear horizontal flat terminals and a PR121/P-LSIG R4000 electronic overcurrent release.

What is the rated current of the E4S4000 PR121/P-LSIG?

The ABB E4S4000 PR121/P-LSIG 1SDA056794R1 has a rated operational and uninterrupted current of 4000 A.

What protection functions does the PR121/P-LSIG release provide?

The PR121/P-LSIG electronic release provides long-time overload protection (L), short-time short-circuit protection (S), instantaneous short-circuit protection (I) and earth-fault protection (G).

Is ABB 1SDA056794R1 fixed or withdrawable?

ABB 1SDA056794R1 is a fixed four-pole air circuit breaker with rear horizontal flat main terminals.

What is the rated operational voltage of ABB 1SDA056794R1?

The E4S4000 PR121/P-LSIG has a rated operational voltage of 690 V AC, with a rated insulation voltage of 1000 V.

What is the short-circuit breaking capacity of ABB 1SDA056794R1?

The E4S4000 provides a rated ultimate short-circuit breaking capacity of 75 kA and a rated service short-circuit breaking capacity of 75 kA across its specified AC operating-voltage range.

Trusted by Electrical Engineers Worldwide

ABB SACE Emax air circuit breakers are widely used in industrial, commercial and infrastructure power distribution systems where dependable high-current switching, comprehensive electronic protection and robust low-voltage switchgear performance are required.