1SDA056753R1 ABB E3L2500 PR121/P-LSI 2500 A 3-Pole Fixed Air Circuit Breaker

1SDA056753R1 ABB E3L2500 PR121/P-LSI 2500 A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA056753R1 E3L2500 is a 2500 A three-pole fixed SACE Emax air circuit breaker with a PR121/P-LSI electronic trip unit providing LSI protection for high-current low-voltage power distribution systems.

SKU: 1SDA056753R1MPN: 1SDA056753R1
Price
List Price £23,701.17 ex VAT
Your Price (ex VAT) Save 25%
£17,775.88 25% OFF
You save £5,925.29 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,775.88
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,775.88

Why Choose the ABB E3L2500 PR121/P-LSI Air Circuit Breaker?

The ABB 1SDA056753R1 is a high-performance SACE Emax E3L air circuit breaker designed for switching and protection in high-current low-voltage electrical distribution systems. Identified as E3L2500PR121/P-LSI, this three-pole fixed circuit breaker combines a 2500 A rated current with ABB's PR121/P-LSI electronic overcurrent release for dependable circuit protection.

As part of the ABB SACE Emax / New Emax E3 range, the E3L2500 is engineered for demanding industrial, commercial and infrastructure power distribution applications. Its L short-circuit performance level provides an ultimate short-circuit breaking capacity of 130 kA at 400 V AC, while its fixed construction and rear flat horizontal terminals provide a robust installation arrangement for low-voltage switchboards.

The integrated PR121/P-LSI electronic trip unit provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection. With a rated operational voltage of up to 690 V AC, three-pole configuration and 2500 A rated uninterrupted current, the 1SDA056753R1 is well suited to main incoming, feeder and distribution protection duties in substantial low-voltage installations.

Key Advantages

  • High-capacity 2500 A air circuit breaker for low-voltage power distribution.
  • Three-pole configuration for three-phase electrical systems.
  • PR121/P-LSI electronic trip unit provides long-time, short-time and instantaneous overcurrent protection.
  • High 130 kA Icu at 400 V AC ultimate short-circuit breaking capacity.
  • Fixed circuit breaker construction for permanent switchboard installations.
  • Rear flat horizontal terminals support practical switchboard connection.
  • Rated for operation at voltages up to 690 V AC.
  • Part of ABB's proven SACE Emax circuit breaker range for demanding power distribution applications.

Key Features

  • ABB SACE Emax E3L series.
  • 2500 A rated operational and uninterrupted current.
  • Three-pole circuit breaker configuration.
  • PR121/P-LSI electronic overcurrent release.
  • Long-time overload, short-time and instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 130 kA Icu and Ics at 400 V AC.
  • 85 kA Icu at 690 V AC.
  • Fixed circuit breaker design with rear flat horizontal terminals.
  • 15,000-operation mechanical endurance.
  • Fitted with four auxiliary contacts and open/closed position indication.

Reliable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB E3L2500 provide switching and protection for high-current low-voltage distribution systems. The circuit breaker interrupts abnormal current conditions to help protect cables, busbars, switchgear and connected equipment against damage caused by overloads and short circuits.

The PR121/P-LSI electronic release provides long-time overload, short-time and instantaneous short-circuit protection. Combined with the E3L's high breaking performance and fixed installation design, this makes the 1SDA056753R1 suitable for distribution boards, switchboards and industrial installations where dependable and selective electrical protection is required.

Typical Applications

  • Main incoming circuit protection in low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer and generator protection systems.
  • Protection of distribution feeders and busbar systems.
  • Large commercial and infrastructure electrical installations.
  • Manufacturing plants and process facilities.
  • High-current switchgear and electrical distribution installations.

Technical Specifications

Series SACE Emax / New Emax E3
Product group 310513-New Emax
ABB order code 1SDA056753R1
Product type Air circuit breaker
Frame E3
Short-circuit performance level L
Rated current (In) 2500 A
Rated operational current (Ie) 2500 A
Rated uninterrupted current (Iu) 2500 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Current type AC
Trip unit PR121/P-LSI
Trip unit type Electronic
Protection functions L, S and I
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 130 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 130 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 110 kA
Service short-circuit breaking capacity (Ics) at 440 V AC 110 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 65 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 65 kA
Rated short-time withstand current (Icw), 1 s 15 kA
Installation type Fixed
Terminal connection Rear flat horizontal
Version F
Auxiliary contacts 4
Position indication Open / closed
Mechanical endurance 15,000 operations
Electrical endurance at ≤440 V AC 1,800 operations
Electrical endurance at 500–690 V AC 1,300 operations
Power loss 335 W
Dimensions (H × W × D) 418 × 404 × 302 mm
Net weight 60 kg
Standard IEC
EAN 8015644580933

Frequently Asked Questions

What is the ABB 1SDA056753R1 used for?

The ABB 1SDA056753R1 is a 2500 A three-pole air circuit breaker used for switching and protecting high-current low-voltage electrical distribution systems.

What trip unit is fitted to the ABB E3L2500?

This version is fitted with the ABB PR121/P-LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the rated current of the 1SDA056753R1?

The circuit breaker has a rated operational and uninterrupted current of 2500 A.

What is the breaking capacity of the ABB E3L2500?

The E3L performance version has an ultimate short-circuit breaking capacity (Icu) and service short-circuit breaking capacity (Ics) of 130 kA at 400 V AC.

Is the ABB 1SDA056753R1 a fixed or withdrawable circuit breaker?

The 1SDA056753R1 is a fixed SACE Emax circuit breaker with rear flat horizontal terminals, designed for permanent installation within low-voltage switchboards and power distribution assemblies.

Trusted ABB Power Distribution Protection

ABB SACE Emax air circuit breakers are designed for demanding low-voltage power distribution applications, combining high breaking performance, electronic protection and robust construction for dependable electrical system protection.