1SDA056701R1 ABB E3V 3200 PR122/P-LSIG 3200 A 4-Pole Air Circuit Breaker

1SDA056701R1 ABB E3V 3200 PR122/P-LSIG 3200 A 4-Pole Air Circuit Breaker

ABB 1SDA056701R1 SACE Emax E3V 3200 four-pole fixed air circuit breaker with 3200 A rated current and PR122/P-LSIG electronic long-time, short-time, instantaneous and ground-fault protection.

SKU: 1SDA056701R1MPN: 1SDA056701R1
Price
List Price £38,807.29 ex VAT
Your Price (ex VAT) Save 25%
£29,105.47 25% OFF
You save £9,701.82 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £29,105.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£29,105.47

Why Choose the ABB 1SDA056701R1 E3V 3200 Air Circuit Breaker?

The ABB 1SDA056701R1 is a high-performance SACE Emax E3V air circuit breaker designed for protection and switching in demanding low-voltage electrical distribution systems. Configured as an E3V 3200 PR122/P-LSIG, this four-pole fixed circuit breaker combines a rated current of 3200 A with ABB's PR122/P electronic overcurrent release.

As part of the ABB SACE Emax series, the E3V 3200 is engineered for installations requiring high short-circuit performance, selective protection and dependable operation. The PR122/P-LSIG release provides long-time, short-time, instantaneous and ground-fault protection functions, helping protect electrical installations against overloads, short circuits and earth faults while supporting coordinated protection throughout the distribution system.

This configuration is a four-pole fixed air circuit breaker suitable for high-current three-phase distribution systems where switching of the neutral conductor is required. Its 3200 A current rating, E3V performance level and comprehensive LSIG electronic protection make it suitable for main incomers, high-capacity feeders and critical industrial and commercial switchboard applications.

Key Advantages

  • High-performance ABB SACE Emax E3V air circuit breaker for demanding low-voltage distribution systems.
  • 3200 A rated current for high-capacity industrial and commercial power distribution.
  • PR122/P-LSIG R3200 electronic trip unit providing comprehensive adjustable circuit protection.
  • LSIG protection provides long-time, short-time, instantaneous and ground-fault protection functions.
  • Four-pole configuration supports applications requiring switching and isolation of the neutral conductor.
  • Integrated ground-fault protection provides an additional layer of protection for distribution systems and connected equipment.
  • Electronic protection supports selective coordination throughout complex electrical distribution networks.
  • Fixed construction provides robust permanent installation within compatible low-voltage switchboards.

Key Features

  • ABB SACE Emax E3V 3200 series.
  • 3200 A rated current.
  • Four-pole configuration.
  • Fixed circuit breaker construction.
  • PR122/P-LSIG R3200 electronic overcurrent release.
  • LSIG protection functions for long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.
  • Integrated ground-fault protection through the LSIG electronic release.
  • Adjustable electronic protection for effective system coordination.
  • Four-pole design suitable for three-phase and neutral distribution arrangements.
  • Designed for high-current low-voltage switchboard applications.
  • Suitable for main distribution and critical high-capacity feeder protection.

Comprehensive Four-Pole Protection for High-Current Distribution

Air circuit breakers such as the ABB SACE Emax E3V provide switching and protection for low-voltage electrical distribution systems where substantial load currents and prospective fault currents can occur. The E3V 3200 combines a 3200 A current rating with comprehensive electronic protection, helping safeguard switchboards, busbars, cables and connected equipment against damaging overload, short-circuit and ground-fault conditions.

The PR122/P-LSIG electronic trip unit combines long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection. Together with its four-pole construction, these functions make the 1SDA056701R1 well suited to high-current three-phase distribution systems where neutral switching, selective coordination, earth-fault protection and dependable fixed circuit protection are required.

Typical Applications

  • Main incoming circuit protection in low-voltage switchboards.
  • Industrial power distribution systems.
  • High-current distribution feeders.
  • High-fault-level electrical distribution systems.
  • Manufacturing and process plant electrical systems.
  • Commercial and infrastructure power distribution.
  • Generator and transformer distribution systems.
  • Three-phase systems requiring four-pole switching and neutral isolation.
  • Critical circuits requiring comprehensive LSIG electronic protection.
  • Fixed switchgear requiring high-capacity 3200 A circuit protection.

Technical Specifications

Series SACE Emax
Product group 310513-New Emax
Order code 1SDA056701R1
Product type Air circuit breaker
Frame E3
Performance level V
Frame size 3200 A
Rated current (In) 3200 A
Number of poles 4
Installation Fixed
Trip unit PR122/P-LSIG R3200
Release type Electronic overcurrent release
Protection functions Long-time, short-time, instantaneous and ground fault (LSIG)
Ground-fault protection Integrated through LSIG release
Rating plug 3200 A
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA056701R1 used for?

The ABB 1SDA056701R1 is a 3200 A four-pole fixed air circuit breaker used for switching and protecting demanding low-voltage electrical distribution systems, including main incomers and high-current distribution feeders.

What is the rated current of the ABB 1SDA056701R1?

The circuit breaker has a rated current of 3200 A and is equipped with a PR122/P-LSIG R3200 electronic overcurrent release.

What protection does the PR122/P-LSIG trip unit provide?

The PR122/P-LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection, supporting comprehensive and selective protection within the electrical distribution system.

Why does the ABB 1SDA056701R1 use LSIG protection?

LSIG protection combines long-time, short-time, instantaneous and ground-fault protection, allowing the breaker to protect against overloads and multiple types of electrical fault while supporting selective coordination with other protective devices.

Is the ABB 1SDA056701R1 fixed or withdrawable?

The 1SDA056701R1 is a four-pole fixed air circuit breaker designed for permanent installation within compatible low-voltage switchboards.

Trusted Protection from ABB

ABB SACE Emax air circuit breakers are designed for dependable switching and protection in demanding low-voltage power distribution systems, combining high-current capability, comprehensive electronic protection and robust construction for critical industrial and commercial installations.