1SDA056680R1 ABB E3V2500 PR121/P-LI 2500 A 4-Pole Withdrawable Air Circuit Breaker

1SDA056680R1 ABB E3V2500 PR121/P-LI 2500 A 4-Pole Withdrawable Air Circuit Breaker

ABB 1SDA056680R1 E3V2500 is a 2500 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LI electronic overcurrent release for high-current low-voltage power distribution.

SKU: 1SDA056680R1Alt SKU: E3V2500PR121/P-LIIMPN: 1SDA056680R1
Price
List Price £35,268.67 ex VAT
Your Price (ex VAT) Save 25%
£26,451.50 25% OFF
You save £8,817.17 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £26,451.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£26,451.50

Why Choose the ABB E3V2500 PR121/P-LI Air Circuit Breaker?

The ABB E3V2500 PR121/P-LI, order code 1SDA056680R1, is a high-performance SACE Emax air circuit breaker (ACB) moving part designed for protection and switching in high-current low-voltage power-distribution systems. Part of the ABB SACE Emax E3 series, this four-pole withdrawable configuration combines a 2500 A rated current with the PR121/P-LI electronic overcurrent release.

The PR121/P-LI release provides long-time overload and instantaneous short-circuit protection, helping protect switchboards, conductors and downstream electrical equipment against damaging overcurrents. The E3V performance level provides high short-circuit breaking capability for demanding industrial, commercial and infrastructure power-distribution installations.

This model is a four-pole withdrawable moving part rated for operation up to 690 V AC. It incorporates four auxiliary contacts and open/closed position indication, while its withdrawable construction supports inspection, maintenance and replacement within compatible SACE Emax fixed parts without permanently disturbing the main switchboard installation.

Key Advantages

  • High-current 2500 A SACE Emax air circuit breaker moving part.
  • PR121/P-LI electronic overcurrent release provides overload and instantaneous short-circuit protection.
  • Four-pole configuration for switching and protection of three-phase systems with neutral.
  • Withdrawable construction supports efficient switchboard maintenance and servicing.
  • High V-level short-circuit performance for demanding electrical distribution networks.
  • 690 V AC rated operational voltage supports a wide range of industrial applications.
  • Integrated auxiliary contacts and position indication support switchboard monitoring and control.

Key Features

  • ABB SACE Emax E3V2500 air circuit breaker moving part.
  • 2500 A rated current.
  • Four-pole withdrawable version.
  • PR121/P-LI electronic overcurrent release.
  • L protection: long-time overload protection.
  • I protection: instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four auxiliary contacts with open/closed position indication.
  • High short-circuit breaking capacity for demanding low-voltage distribution systems.

Reliable Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E3V2500 provide switching and overcurrent protection at main incomer and feeder levels of low-voltage electrical distribution systems. The PR121/P-LI electronic release monitors circuit current and provides long-time protection against sustained overload conditions together with instantaneous tripping during severe short-circuit faults.

The withdrawable design is particularly valuable in critical switchboards where maintenance accessibility and service continuity are important. The moving part can be disconnected from its compatible fixed section for inspection or servicing, while the E3V platform provides the high current and short-circuit performance required by demanding industrial power networks.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power-distribution systems.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical installations.
  • Transformer secondary and main incomer protection.
  • High-current feeder protection.
  • Withdrawable switchgear and power-distribution assemblies.

Technical Specifications

Series SACE Emax E3
ABB order code 1SDA056680R1
Product type Air circuit breaker moving part
Frame E3
Short-circuit performance level V
Rated current 2500 A
Rated uninterrupted current 2500 A
Rated operational current 2500 A
Number of poles 4P
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Release PR121/P-LI
Release type Electronic
Protection functions LI — long-time and instantaneous
Version Withdrawable
Rated ultimate short-circuit breaking capacity at 380–440 V AC 130 kA
Rated ultimate short-circuit breaking capacity at 500–690 V AC 100 kA
Rated service short-circuit breaking capacity at 380–440 V AC 100 kA
Rated service short-circuit breaking capacity at 500–690 V AC 85 kA
Rated short-time withstand current 85 kA for 1 s; 65 kA for 3 s
Power loss 350 W
Electrical durability 8000 cycles at ≤440 V AC; 7000 cycles at 500–690 V AC
Mechanical durability 20,000 cycles
Auxiliary contacts 4
Position indication Open / closed
Dimensions (W × H × D) 558 × 461 × 396.5 mm
Net weight 81 kg
EAN 8015644580209
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA056680R1 used for?

The ABB 1SDA056680R1 is a 2500 A four-pole SACE Emax air circuit breaker moving part used for switching and overcurrent protection in high-current low-voltage power-distribution systems.

What protection release is fitted to the ABB E3V2500?

This circuit breaker is fitted with an ABB PR121/P-LI electronic release, providing long-time overload and instantaneous short-circuit protection.

What is the rated current of the ABB E3V2500 PR121/P-LI?

The circuit breaker has a rated current of 2500 A.

Is the ABB 1SDA056680R1 fixed or withdrawable?

The 1SDA056680R1 is a withdrawable four-pole moving part designed for use with the corresponding ABB SACE Emax fixed section.

What does LI mean on the PR121/P release?

LI denotes long-time overload and instantaneous short-circuit protection, providing protection against sustained overcurrents and severe fault currents.

Trusted Protection for Industrial Power Systems

ABB SACE Emax air circuit breakers provide dependable switching and electronic protection for demanding low-voltage distribution systems, combining high current capability, robust short-circuit performance and service-friendly withdrawable construction.