ABB 1SDA056642R1 is a SACE Emax E3 V 2000 A three-pole withdrawable air circuit breaker with a PR121/P-LSIG electronic release providing long-time, short-time, instantaneous and earth-fault protection for demanding low-voltage power distribution systems.
£17,057.20
The ABB 1SDA056642R1 is a high-performance SACE Emax E3 V withdrawable air circuit breaker (ACB) designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the ABB SACE Emax series, this three-pole breaker combines a 2000 A rated current with advanced electronic protection and high short-circuit performance for industrial, commercial and infrastructure power distribution applications.
The E3V2000 is equipped with an ABB PR121/P-LSIG electronic overcurrent release, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. These L, S, I and G protection functions provide comprehensive protection while supporting selective coordination within complex low-voltage distribution networks.
With a rated current of 2000 A, a three-pole withdrawable configuration and a rated operational voltage of up to 690 V AC, the 1SDA056642R1 is well suited to main distribution boards, industrial switchgear and high-current feeder applications. The E3 V performance level provides a rated ultimate short-circuit breaking capacity of 130 kA at 400 V AC for installations with high prospective fault currents.
Air circuit breakers such as the ABB SACE Emax E3V2000 provide controlled switching and protection for high-current low-voltage distribution circuits. The PR121/P-LSIG electronic release combines long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, helping safeguard switchboards, conductors and connected electrical equipment against a broad range of damaging fault conditions.
The short-time protection function supports selective coordination between protective devices, while the earth-fault function provides additional protection against ground-fault conditions. Combined with the high-breaking-capacity E3 V platform and withdrawable construction, the 1SDA056642R1 is particularly suited to industrial switchgear where dependable protection, maintainability and system availability are important.
| Product group | 310513-New Emax |
|---|---|
| Series | SACE Emax E3 |
| ABB order code | 1SDA056642R1 |
| Product type | Air circuit breaker |
| Frame | E3 |
| Performance level | V |
| Rated current (In) | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Release | PR121/P-LSIG |
| Release type | Electronic |
| Protection functions | Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) |
| Rated ultimate short-circuit breaking capacity (Icu) at 380–440 V AC | 130 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 660–690 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 380–440 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 500–690 V AC | 85 kA |
| Rated short-time withstand current (Icw), 1 s | 85 kA |
| Rated short-time withstand current (Icw), 3 s | 65 kA |
| Current type | AC |
| Version | Withdrawable |
| Standard | IEC |
The ABB 1SDA056642R1 is a SACE Emax E3 V air circuit breaker used for switching and protecting high-current low-voltage electrical distribution circuits in industrial, commercial and infrastructure installations.
The circuit breaker has a rated current of 2000 A.
The 1SDA056642R1 is fitted with an ABB PR121/P-LSIG electronic overcurrent release, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.
The E3 V version provides a rated ultimate short-circuit breaking capacity of 130 kA at 400 V AC and a rated service short-circuit breaking capacity of 100 kA at 400 V AC.
The 1SDA056642R1 is a three-pole withdrawable air circuit breaker designed for integration into compatible SACE Emax withdrawable switchgear installations.
ABB SACE Emax air circuit breakers are widely used in demanding low-voltage power distribution systems where advanced electronic protection, high short-circuit performance and serviceable switchgear configurations are required.