ABB 1SDA056618R1 E3V1600 PR121/P-LSIG is a 1600 A four-pole withdrawable SACE Emax air circuit breaker moving part with PR121/P-LSIG electronic LSIG protection and a 130 kA ultimate short-circuit breaking capacity at 400–415 V AC.
£15,120.82
The ABB E3V1600 PR121/P-LSIG, order code 1SDA056618R1, is a high-performance SACE Emax air circuit breaker (ACB) moving part designed for switching and comprehensive protection in demanding low-voltage power distribution systems. As part of the ABB SACE Emax E3 series, this four-pole withdrawable breaker combines a 1600 A current rating with the PR121/P-LSIG R1600 electronic overcurrent release.
This E3V breaker is supplied as the moving part for a withdrawable four-pole installation, allowing convenient removal from the associated fixed part for inspection, servicing and maintenance. The PR121/P-LSIG electronic release provides long-time, short-time, instantaneous and earth-fault protection, helping safeguard electrical installations against overloads, short circuits and earth faults.
With a rated uninterrupted current of 1600 A and an ultimate short-circuit breaking capacity of 130 kA at 400–415 V AC, the E3V1600 is engineered for installations with demanding prospective fault currents. Its rated short-time withstand current of 85 kA for 1 s further supports dependable operation in high-current industrial and infrastructure distribution systems.
Air circuit breakers such as the ABB SACE Emax E3V provide switching and overcurrent protection for high-current low-voltage distribution systems. Their high interruption capability helps protect switchboards, cables, transformers and connected electrical equipment against damaging overload, short-circuit and earth-fault conditions.
The PR121/P-LSIG electronic release combines long-time, short-time and instantaneous overcurrent protection with integrated earth-fault protection. Together with the withdrawable construction, high breaking capacity and auxiliary status contacts, the 1SDA056618R1 provides a robust and maintainable protection solution for critical industrial power-distribution systems.
| Series | SACE Emax E3 |
|---|---|
| ABB order code | 1SDA056618R1 |
| Product type | Air circuit breaker moving part |
| Frame / performance level | E3V |
| Rated uninterrupted current (Iu) | 1600 A |
| Release rated current | 1600 A |
| Number of poles | 4 |
| Installation | Withdrawable |
| Protection release | PR121/P-LSIG R1600 electronic release |
| Protection functions | LSIG – long-time, short-time, instantaneous and earth-fault |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 130 kA |
| Rated service short-circuit breaking capacity (Ics) at 400–415 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 500 V AC | 85 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Rated service short-circuit breaking capacity (Ics) at 690 V AC | 85 kA |
| Rated short-time withstand current (Icw), 1 s | 85 kA |
| Rated short-time withstand current (Icw), 3 s | 65 kA |
| Overload release setting range | 400–1600 A |
| Short-time short-circuit release setting range | 1600–16000 A |
| Instantaneous short-circuit release setting range | 2400–24000 A |
| Earth-fault protection | Integrated |
| Protection rating | IP20 |
| Auxiliary contacts | 2 NO + 2 NC |
| Position indication | Open / closed |
| Operating element | Push-button |
| Motor operating mechanism | Optional |
| Dimensions (W × H) | 558 × 461 mm |
| Weight | approx. 96 kg |
| Standard | IEC |
| EAN | 8015644579586 |
The ABB 1SDA056618R1 is a 1600 A four-pole SACE Emax E3V air circuit breaker moving part used for switching and comprehensive overcurrent protection in demanding low-voltage power distribution systems.
The breaker is fitted with the PR121/P-LSIG R1600 electronic overcurrent release, providing long-time, short-time, instantaneous and earth-fault protection.
The E3V1600 has a rated ultimate short-circuit breaking capacity of 130 kA at 400–415 V AC and 100 kA at 690 V AC.
The 1SDA056618R1 is the moving part of a withdrawable four-pole air circuit breaker, allowing it to be removed from the associated fixed part for inspection and maintenance.
Yes. The PR121/P-LSIG electronic release provides integrated earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
ABB SACE Emax air circuit breakers are engineered for dependable switching and comprehensive electrical protection in demanding low-voltage distribution systems, combining high interruption performance with electronic protection and maintainable withdrawable construction.