ABB 1SDA056613R1 SACE Emax E3V 1600 three-pole withdrawable air circuit breaker moving part with 1600 A rated current, PR122/P-LSIG electronic protection and up to 130 kA ultimate short-circuit breaking capacity.
£12,349.22
The ABB 1SDA056613R1 is a high-performance SACE Emax E3V air circuit breaker moving part designed for protection and switching in demanding low-voltage electrical distribution systems. Configured as an E3V 1600 PR122/P-LSIG, this three-pole withdrawable unit combines a rated uninterrupted current of 1600 A with ABB's PR122/P electronic overcurrent release.
As part of the ABB SACE Emax series, the E3V 1600 is engineered for installations requiring high short-circuit performance, selective protection and dependable operation. The PR122/P-LSIG release provides long-time, short-time, instantaneous and ground-fault protection functions, helping protect electrical installations against overloads, short circuits and earth faults while supporting coordinated protection throughout the distribution system.
This configuration is a three-pole withdrawable moving part with a rated operational voltage of 690 V AC. The E3V performance level provides an ultimate short-circuit breaking capacity of 130 kA at 220–440 V AC and 100 kA at 500–690 V AC, making it suitable for high-fault-level industrial switchboards and critical power distribution systems.
Air circuit breakers such as the ABB SACE Emax E3V provide switching and protection for low-voltage electrical distribution systems where substantial prospective fault currents can occur. The E3V 1600 combines a 1600 A current rating with high short-circuit interruption capability, helping protect switchboards, busbars, cables and connected equipment against damaging overload, short-circuit and earth-fault conditions.
The PR122/P-LSIG electronic trip unit combines long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection. These functions provide comprehensive protection for critical distribution circuits, while the withdrawable construction allows the breaker moving part to be isolated and removed from compatible switchgear for inspection, servicing and maintenance.
| Series | SACE Emax |
|---|---|
| Product group | 310513-New Emax |
| Order code | 1SDA056613R1 |
| EAN | 8015644579531 |
| Customs tariff number | 85362090 |
| Product type | Air circuit breaker moving part |
| Frame | E3 |
| Performance level | V |
| Rated current (In) | 1600 A |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational current (Ie) | 1600 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated voltage (Ur) | 690 V |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Current type | AC |
| Number of poles | 3 |
| Installation | Withdrawable |
| Version | W / moving part |
| Trip unit | PR122/P-LSIG R1600 |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and ground fault (LSIG) |
| Ultimate short-circuit breaking capacity (Icu) at 220–440 V AC | 130 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500–690 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 220–440 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 500–690 V AC | 85 kA |
| Short-time withstand current (Icw), 1 s | 85 kA |
| Short-time withstand current (Icw), 3 s | 65 kA |
| Short-circuit current at 480 V | 125 kA |
| Power loss | 150 W |
| Electrical durability at ≤440 V | 10000 cycles |
| Electrical durability at 500–690 V | 10000 cycles |
| Electrical operating frequency | 20 cycles per hour |
| Mechanical durability | 20000 cycles |
| Mechanical operating frequency | 60 cycles per hour |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Ground-fault protection | Integrated through LSIG release |
| Product net width | 432 mm |
| Product net height | 461 mm |
| Product net depth | 396.5 mm |
| Product net weight | 64 kg |
| Standard | IEC |
The ABB 1SDA056613R1 is a 1600 A withdrawable air circuit breaker moving part used for switching and protecting demanding low-voltage electrical distribution systems, including main incomers and high-current distribution feeders.
The circuit breaker moving part has a rated uninterrupted current of 1600 A and is equipped with a PR122/P-LSIG R1600 electronic overcurrent release.
The PR122/P-LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.
The E3V 1600 has an ultimate short-circuit breaking capacity of 130 kA at 220–440 V AC and 100 kA at 500–690 V AC, with a short-time withstand current of 85 kA for 1 s.
The 1SDA056613R1 is a three-pole withdrawable air circuit breaker moving part designed for use with a compatible ABB SACE Emax fixed part and switchgear assembly.
ABB SACE Emax air circuit breakers are designed for dependable switching and protection in demanding low-voltage power distribution systems, combining high short-circuit performance, comprehensive electronic protection and maintainable withdrawable construction for critical industrial and commercial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.