Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA056594R1 E3V 1600 PR121/P-LSIG is a 1600 A three-pole fixed SACE Emax air circuit breaker with rear horizontal terminals and electronic LSIG protection for demanding low-voltage power distribution systems.
£11,019.74
The ABB E3V 1600 PR121/P-LSIG, order code 1SDA056594R1, is a high-performance fixed air circuit breaker (ACB) designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the proven ABB SACE Emax E3 series, this three-pole breaker combines a 1600 A rated current with the PR121/P-LSIG electronic overcurrent release.
The PR121/P-LSIG trip unit provides long-time, short-time, instantaneous and earth-fault protection, helping safeguard electrical installations against overloads, short circuits and ground faults. The E3V performance level provides high short-circuit capability for industrial switchboards, power distribution assemblies and infrastructure applications where dependable protection and service continuity are essential.
This version is configured as a 3-pole fixed breaker with rear horizontal terminals and a PR121/P-LSIG R1600 release. It is also fitted with four auxiliary contacts and open/closed circuit-breaker position indication, supporting effective integration into switchboard monitoring, signalling and control systems.
Air circuit breakers such as the ABB E3V provide switching and protection for high-current low-voltage distribution circuits. The PR121/P-LSIG electronic release monitors current and provides long-time, short-time, instantaneous and earth-fault protection functions, helping safeguard cables, busbars and connected equipment against damaging electrical faults.
The fixed SACE Emax configuration is suited to switchboards where a permanently installed circuit breaker is required. Rear horizontal terminals facilitate integration with suitable busbar arrangements, while the auxiliary contacts and breaker position indication support signalling, supervision and automation functions.
| Series | SACE Emax E3 |
|---|---|
| Order code | 1SDA056594R1 |
| Product type | Air circuit breaker |
| Rated current (In) | 1600 A |
| Number of poles | 3P |
| Release | PR121/P-LSIG R1600 |
| Release type | Electronic overcurrent release |
| Protection functions | LSIG – long-time, short-time, instantaneous and earth-fault |
| Version | Fixed |
| Terminal arrangement | Rear horizontal |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 130 kA |
| Rated short-time withstand current (Icw) | 85 kA for 1 s |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| EAN | 8015644579340 |
| Weight | 72 kg |
It is a 1600 A air circuit breaker used for switching and protecting low-voltage electrical distribution systems against overload, short-circuit and earth-fault conditions.
The breaker uses an ABB PR121/P-LSIG R1600 electronic release, providing long-time, short-time, instantaneous and earth-fault protection functions.
This version is a 3-pole air circuit breaker with a rated current of 1600 A.
The 1SDA056594R1 is a fixed-version SACE Emax E3V circuit breaker equipped with rear horizontal terminals.
The E3V platform provides a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC and a short-time withstand current of 85 kA for 1 s.
ABB SACE Emax air circuit breakers are engineered for dependable protection and switching in demanding low-voltage power distribution systems, combining advanced electronic protection with robust construction and high short-circuit performance.
We use cookies