1SDA056587R1 ABB E3V1250 PR122/P-LI 1250A 4P Withdrawable Air Circuit Breaker

1SDA056587R1 ABB E3V1250 PR122/P-LI 1250A 4P Withdrawable Air Circuit Breaker

ABB 1SDA056587R1 E3V1250 PR122/P-LI is a 1250 A four-pole withdrawable SACE Emax air circuit breaker moving part with PR122/P-LI electronic protection and a 130 kA ultimate short-circuit breaking capacity at 415 V AC.

SKU: 1SDA056587R1MPN: 1SDA056587R1
Price
List Price £15,362.99 ex VAT
Your Price (ex VAT) Save 25%
£11,522.24 25% OFF
You save £3,840.75 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,522.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,522.24

Why Choose the ABB E3V1250 PR122/P-LI 1250A 4P Withdrawable Air Circuit Breaker?

The ABB E3V1250 PR122/P-LI, order code 1SDA056587R1, is a high-performance SACE Emax air circuit breaker (ACB) moving part designed for switching and overcurrent protection in demanding low-voltage power distribution systems. As part of the ABB SACE Emax E3 series, this four-pole withdrawable breaker combines a 1250 A current rating with the PR122/P-LI R1250 electronic overcurrent release.

This E3V breaker is supplied as the moving part for a withdrawable four-pole installation, enabling convenient removal from the associated fixed part for inspection and maintenance. The PR122/P-LI electronic release provides long-time overload and instantaneous short-circuit protection, while four auxiliary contacts and open/closed position indication support integration with switchboard monitoring and control systems.

With a rated uninterrupted current of 1250 A, rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 130 kA at 415 V AC, the E3V1250 is engineered for high-current installations with demanding prospective fault levels. Its rated short-time withstand current of 85 kA for 1 s further supports reliable operation in heavy-duty electrical distribution applications.

Key Advantages

  • High-performance ABB SACE Emax E3V air circuit breaker moving part.
  • 1250 A rated uninterrupted current for high-current distribution systems.
  • Four-pole withdrawable configuration supports convenient servicing and maintenance.
  • Advanced PR122/P-LI R1250 electronic overcurrent release.
  • Provides long-time overload and instantaneous short-circuit protection.
  • High 130 kA ultimate short-circuit breaking capacity at 415 V AC.
  • 85 kA short-time withstand current for 1 s.
  • Four auxiliary contacts and open/closed position indication support switchboard monitoring.

Key Features

  • ABB SACE Emax E3V series.
  • 1250 A rated uninterrupted current (Iu).
  • Four-pole circuit-breaker configuration.
  • Withdrawable moving part construction.
  • PR122/P-LI R1250 electronic overcurrent release.
  • LI protection functions for long-time and instantaneous protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 130 kA Icu at 415 V AC.
  • 100 kA Ics at 415 V AC.
  • 85 kA Icw for 1 s.
  • 65 kA Icw for 3 s.
  • Fitted with four auxiliary contacts and open/closed position indication.

Reliable LI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E3V provide switching and overcurrent protection for high-current low-voltage distribution systems. Their high interruption capability helps protect switchboards, cables, transformers and connected electrical equipment against damaging overload and short-circuit conditions.

The PR122/P-LI electronic release combines long-time overload protection with instantaneous short-circuit protection. Together with the withdrawable construction, high breaking capacity and auxiliary status contacts, the 1SDA056587R1 provides a robust and maintainable solution for critical industrial and infrastructure power-distribution systems.

Typical Applications

  • Industrial low-voltage switchboards and distribution systems.
  • Main incoming and feeder circuit protection.
  • Transformer secondary protection.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • High-current installations with demanding prospective fault levels.

Technical Specifications

Series SACE Emax E3
ABB order code 1SDA056587R1
Product type Air circuit breaker moving part
Frame / performance level E3V
Rated uninterrupted current (Iu) 1250 A
Rated operational current (Ie) 1250 A
Number of poles 4
Installation Withdrawable
Protection release PR122/P-LI R1250 electronic release
Protection functions LI – long-time and instantaneous
Current type AC
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 130 kA
Rated service short-circuit breaking capacity (Ics) at 415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) at 690 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 85 kA
Rated short-time withstand current (Icw), 3 s 65 kA
Power loss 90 W
Electrical durability 12,000 cycles
Mechanical durability 20,000 cycles
Auxiliary contacts 4
Position indication Open / closed
Dimensions (W × H × D) 558 × 461 × 396.5 mm
Net weight 81 kg
Standard IEC
EAN 8015644579272

Frequently Asked Questions

What is the ABB 1SDA056587R1 used for?

The ABB 1SDA056587R1 is a 1250 A four-pole SACE Emax E3V air circuit breaker moving part used for switching and overcurrent protection in demanding low-voltage power distribution systems.

What protection release is fitted to the ABB E3V1250?

The breaker is fitted with the PR122/P-LI R1250 electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E3V1250 PR122/P-LI?

The E3V1250 has a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC and 100 kA at 690 V AC.

Is the ABB 1SDA056587R1 fixed or withdrawable?

The 1SDA056587R1 is the moving part of a withdrawable four-pole air circuit breaker, allowing removal from the associated fixed part for inspection and maintenance.

What is the rated current of the ABB E3V1250 PR122/P-LI?

The circuit breaker has a rated uninterrupted current of 1250 A and is equipped with a PR122/P-LI R1250 electronic protection release.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax air circuit breakers are engineered for dependable switching and electrical protection in demanding low-voltage distribution systems, combining high interruption performance with advanced electronic protection and maintainable withdrawable construction.