1SDA056556R1 ABB E3V800 PR122/P-LSI 800A 4P Withdrawable Air Circuit Breaker

1SDA056556R1 ABB E3V800 PR122/P-LSI 800A 4P Withdrawable Air Circuit Breaker

ABB 1SDA056556R1 E3V800 PR122/P-LSI is an 800 A four-pole withdrawable SACE Emax air circuit breaker moving part with PR122/P-LSI electronic protection and a 130 kA ultimate breaking capacity at 415 V AC.

SKU: 1SDA056556R1MPN: 1SDA056556R1
Price
List Price £15,645.90 ex VAT
Your Price (ex VAT) Save 25%
£11,734.43 25% OFF
You save £3,911.48 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,734.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,734.43

Why Choose the ABB E3V800 PR122/P-LSI 800A 4P Withdrawable Air Circuit Breaker?

The ABB E3V800 PR122/P-LSI, order code 1SDA056556R1, is a high-performance SACE Emax air circuit breaker (ACB) moving part designed for protection and switching in demanding low-voltage power distribution systems. As part of the ABB SACE Emax E3 series, this four-pole withdrawable breaker combines an 800 A current rating with the advanced PR122/P-LSI electronic overcurrent release and the high short-circuit performance of the E3V platform.

This E3V breaker is supplied as the moving part for a withdrawable four-pole installation, allowing convenient removal from the associated fixed part for inspection and maintenance. The PR122/P-LSI electronic release provides long-time, short-time and instantaneous protection functions, while four auxiliary contacts provide open/closed circuit-breaker position indication.

With a rated uninterrupted current of 800 A, rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 130 kA at 415 V AC, the E3V800 is engineered for installations with demanding fault levels. Its rated short-time withstand current of 85 kA for 1 s further supports reliable operation in high-current industrial distribution systems.

Key Advantages

  • High-performance ABB SACE Emax E3V air circuit breaker moving part for low-voltage distribution.
  • 800 A rated uninterrupted current for high-current electrical systems.
  • Four-pole withdrawable configuration simplifies inspection and maintenance.
  • Advanced PR122/P-LSI electronic overcurrent release.
  • Provides long-time, short-time and instantaneous protection.
  • High 130 kA ultimate breaking capacity at 415 V AC.
  • Four auxiliary contacts provide open/closed position indication.
  • Designed for demanding industrial, commercial and infrastructure power-distribution applications.

Key Features

  • ABB SACE Emax E3V series.
  • 800 A rated uninterrupted current (Iu).
  • Four-pole circuit-breaker configuration.
  • Withdrawable moving part construction.
  • PR122/P-LSI R800 electronic overcurrent release.
  • LSI protection functions for long-time, short-time and instantaneous protection.
  • 690 V AC rated operational voltage.
  • 130 kA Icu at 415 V AC.
  • 100 kA Ics at 415 V AC.
  • 85 kA short-time withstand current for 1 s.
  • 65 kA short-time withstand current for 3 s.
  • 12 kV rated impulse withstand voltage.
  • Fitted with four auxiliary contacts and open/closed position indication.

Advanced Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax E3V provide switching and overcurrent protection for high-current low-voltage distribution systems. The E3V performance level offers high fault-current interruption capability, helping protect switchboards, cables, transformers and connected electrical equipment against potentially damaging short-circuit conditions.

The PR122/P-LSI electronic release provides configurable long-time, short-time and instantaneous protection functions for coordinated electrical protection. Combined with the withdrawable construction, high breaking capacity and auxiliary position indication, the 1SDA056556R1 is well suited to critical installations where protection performance and maintainability are important.

Typical Applications

  • Industrial low-voltage switchboards and distribution systems.
  • Main incoming and feeder circuit protection.
  • Transformer secondary protection.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • High-current installations with demanding prospective fault levels.

Technical Specifications

Series SACE Emax E3
ABB order code 1SDA056556R1
Product type Air circuit breaker moving part
Frame / performance level E3V
Rated uninterrupted current (Iu) 800 A
Rated operational current (Ie) 800 A
Number of poles 4
Installation Withdrawable
Protection release PR122/P-LSI R800 electronic release
Protection functions LSI – long-time, short-time and instantaneous
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 130 kA
Rated service short-circuit breaking capacity (Ics) at 415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) at 690 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 85 kA
Rated short-time withstand current (Icw), 3 s 65 kA
Power loss 36 W
Mechanical durability 20,000 cycles
Auxiliary contacts 4
Position indication Open / closed
Standard IEC
EAN 8015644578961

Frequently Asked Questions

What is the ABB 1SDA056556R1 used for?

The ABB 1SDA056556R1 is an 800 A four-pole SACE Emax E3V air circuit breaker moving part used for switching and overcurrent protection in demanding low-voltage power distribution systems.

What protection release is fitted to the ABB E3V800?

This breaker is fitted with the PR122/P-LSI R800 electronic overcurrent release, providing long-time, short-time and instantaneous protection functions.

What is the breaking capacity of the ABB E3V800 PR122/P-LSI?

The E3V version has a rated ultimate short-circuit breaking capacity of 130 kA at 415 V AC and 100 kA at 690 V AC.

Is the ABB 1SDA056556R1 fixed or withdrawable?

The 1SDA056556R1 is the moving part of a withdrawable four-pole circuit breaker, allowing the breaker to be withdrawn from its associated fixed part for servicing and maintenance.

What is the rated current of the ABB E3V800 PR122/P-LSI?

The circuit breaker has a rated uninterrupted current of 800 A and is equipped with a PR122/P-LSI R800 electronic protection release.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax air circuit breakers are engineered for dependable protection and switching in demanding low-voltage power distribution systems, combining high interruption performance with advanced electronic protection and maintainable withdrawable construction.