1SDA056541R1 ABB E3V800 PR122/P-LSIG 800A 4-Pole Fixed Air Circuit Breaker

1SDA056541R1 ABB E3V800 PR122/P-LSIG 800A 4-Pole Fixed Air Circuit Breaker

ABB 1SDA056541R1 is a SACE Emax E3V800 800 A four-pole fixed air circuit breaker with rear horizontal terminals and a PR122/P-LSIG R800 electronic overcurrent release providing long-time, short-time, instantaneous and earth-fault protection for demanding low-voltage power distribution systems.

SKU: 1SDA056541R1MPN: 1SDA056541R1
Price
List Price £17,022.13 ex VAT
Your Price (ex VAT) Save 25%
£12,766.60 25% OFF
You save £4,255.53 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,766.60
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,766.60

Why Choose the ABB E3V800 PR122/P-LSIG 800A 4-Pole Air Circuit Breaker?

The ABB 1SDA056541R1 is a high-performance SACE Emax E3V air circuit breaker designed for protection and switching in demanding low-voltage electrical distribution systems. Rated at 800 A, this four-pole fixed circuit breaker incorporates ABB’s PR122/P-LSIG R800 electronic overcurrent release for comprehensive protection of industrial, commercial and infrastructure power networks.

As part of the ABB SACE Emax range, the E3V800 combines very high short-circuit performance with advanced electronic protection. The PR122/P-LSIG trip unit provides long-time, short-time, instantaneous and earth-fault protection functions, helping protect electrical installations against overloads, short circuits and earth faults while supporting selective protection and coordination within low-voltage distribution systems.

The E3V800 PR122/P-LSIG has a rated uninterrupted current of 800 A, a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 130 kA at 400 V AC. This version is supplied as a four-pole fixed circuit breaker with rear horizontal terminals, four auxiliary contacts and circuit-breaker open/closed position indication for integration into demanding switchboard applications.

Key Advantages

  • High-performance ABB SACE Emax E3V air circuit breaker for demanding low-voltage power distribution.
  • 800 A rated current for industrial, commercial and infrastructure installations.
  • Four-pole construction for applications requiring switching of all four conductors.
  • PR122/P-LSIG R800 electronic overcurrent release for comprehensive circuit protection.
  • LSIG protection provides long-time, short-time, instantaneous and earth-fault protection.
  • 130 kA ultimate short-circuit breaking capacity at 400 V AC for demanding fault levels.
  • Fixed construction with rear horizontal terminals for robust switchboard integration.

Key Features

  • ABB SACE Emax E3V800 air circuit breaker.
  • 800 A rated uninterrupted current.
  • Four-pole fixed configuration.
  • PR122/P-LSIG R800 electronic overcurrent release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • 690 V AC rated operational voltage.
  • 130 kA Icu at 400 V AC.
  • 100 kA Ics at 400 V AC.
  • 85 kA short-time withstand current for 1 s.
  • 12 kV rated impulse withstand voltage.
  • Rear horizontal main terminals.
  • Four auxiliary contacts with circuit-breaker open/closed position indication.

High-Performance LSIG Protection for Low-Voltage Distribution

Air circuit breakers such as the ABB SACE Emax E3V800 provide switching, isolation and protection for important low-voltage distribution circuits. The four-pole configuration enables switching of three phase conductors and the neutral, making it suitable for electrical systems where complete four-pole isolation is required.

The PR122/P-LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. Combined with the E3V frame’s 130 kA ultimate breaking capacity at 400 V AC and fixed rear-horizontal-terminal construction, this makes the 1SDA056541R1 particularly suitable for main incomers, feeders and critical distribution circuits requiring comprehensive electronic protection and high fault-interruption performance.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incomer and feeder circuit protection.
  • Three-phase systems requiring neutral switching.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical installations.
  • Power distribution centres and fixed switchgear assemblies.

Technical Specifications

Product group 310513-New Emax
Series SACE Emax
Order code / MPN 1SDA056541R1
Product type Air circuit breaker
Frame E3V
Rated current (In) 800 A
Rated operational current (Ie) 800 A
Rated uninterrupted current (Iu) 800 A
Number of poles 4
Execution Fixed
Current type AC
Trip unit PR122/P-LSIG R800 electronic overcurrent release
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth-fault (LSIG)
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 130 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) at 400 V AC 100 kA
Rated service short-circuit breaking capacity (Ics) at 500 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) at 690 V AC 85 kA
Rated short-time withstand current (Icw) 85 kA for 1 s
Main terminal arrangement Rear horizontal
Power loss 22 W
Electrical durability at up to 440 V 12000 cycles
Electrical durability at 500–690 V 12000 cycles
Mechanical durability 20000 cycles
Auxiliary contacts 4
Position indication Circuit breaker open/closed
Standard IEC
EAN 8015644578817
HS code 85362090
Product net weight 90 kg

Frequently Asked Questions

What is the ABB 1SDA056541R1 used for?

The ABB 1SDA056541R1 is a SACE Emax E3V800 air circuit breaker used for switching and protecting low-voltage electrical distribution circuits, particularly applications requiring four-pole switching, high breaking capacity and comprehensive LSIG protection.

What is the rated current of the ABB E3V800 1SDA056541R1?

The circuit breaker has a rated uninterrupted current of 800 A and is equipped with a PR122/P-LSIG R800 electronic overcurrent release.

What protection functions does the PR122/P-LSIG trip unit provide?

The PR122/P-LSIG electronic overcurrent release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.

What is the breaking capacity of the ABB E3V800 1SDA056541R1?

The E3V800 has a rated ultimate short-circuit breaking capacity of 130 kA at 400 V AC and 100 kA at 690 V AC. Its rated service short-circuit breaking capacity is 100 kA at 400 V AC and 85 kA at 690 V AC.

Is the ABB 1SDA056541R1 fixed or withdrawable?

The 1SDA056541R1 is a four-pole fixed air circuit breaker with rear horizontal terminals for integration into compatible ABB SACE Emax low-voltage switchgear assemblies.

Trusted ABB Protection for Critical Power Systems

ABB SACE Emax air circuit breakers are engineered for dependable protection and switching in demanding low-voltage power distribution systems, combining high breaking performance with advanced electronic protection for industrial, commercial and infrastructure installations.