ABB 1SDA056529R1 SACE Emax E3V 800 three-pole fixed air circuit breaker with 800 A rated current, horizontal rear terminals, PR121/P-LSI electronic protection and up to 130 kA ultimate short-circuit breaking capacity.
£9,341.74
The ABB 1SDA056529R1 is a high-performance SACE Emax E3V air circuit breaker (ACB) designed for protection and switching in demanding low-voltage electrical distribution systems. Configured as an E3V 800 PR121/P-LSI, this three-pole fixed circuit breaker combines a rated uninterrupted current of 800 A with ABB's PR121/P electronic overcurrent release.
As part of the ABB SACE Emax series, the E3V 800 is engineered for applications requiring high short-circuit performance, reliable operation and adjustable electronic protection. The PR121/P-LSI release provides long-time, short-time and instantaneous protection functions, helping protect electrical installations against overloads and short circuits while supporting selective coordination within the distribution system.
This configuration is a three-pole fixed circuit breaker with horizontal rear terminals and a rated operational voltage of 690 V AC. The E3V performance level provides an ultimate short-circuit breaking capacity of 130 kA at 380–440 V AC, making the 1SDA056529R1 particularly suitable for high-fault-level industrial switchboards and critical power distribution systems.
Air circuit breakers such as the ABB SACE Emax E3V provide switching and protection for low-voltage electrical distribution systems where substantial prospective fault currents can occur. The E3V performance level offers high short-circuit interruption capability, helping protect switchboards, busbars, cables and connected equipment against damaging overload and short-circuit conditions.
The PR121/P-LSI electronic trip unit provides long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. Its adjustable protection settings allow the breaker to be coordinated with other protective devices in the electrical installation, while the fixed construction and horizontal rear terminals support straightforward integration into compatible low-voltage switchboards.
| Series | SACE Emax |
|---|---|
| Product group | 310513-New Emax |
| Order code | 1SDA056529R1 |
| EAN | 8015644578695 |
| Product type | Air circuit breaker |
| Frame | E3 |
| Performance level | V |
| Rated current (In) | 800 A |
| Rated uninterrupted current (Iu) | 800 A |
| Rated operational current (Ie) | 800 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Installation | Fixed |
| Terminal arrangement | Horizontal rear terminals |
| Trip unit | PR121/P-LSI R800 |
| Release type | Electronic overcurrent release |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Overload release adjustment range | 320–800 A |
| Short-time delayed short-circuit adjustment range | 800–8000 A |
| Instantaneous short-circuit adjustment range | 1200–12000 A |
| Ultimate short-circuit breaking capacity (Icu) at 220–440 V AC | 130 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500–690 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 220–440 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 500–690 V AC | 85 kA |
| Short-time withstand current (Icw), 1 s | 85 kA |
| Short-time withstand current (Icw), 3 s | 65 kA |
| Power loss | 22 W |
| Electrical durability | 12000 cycles |
| Mechanical durability | 20000 cycles |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Open / closed |
| Integrated earth-fault protection | No |
| Integrated motor operator | No |
| Optional motor operator | Yes |
| Weight | approx. 72 kg |
The ABB 1SDA056529R1 is an 800 A air circuit breaker used for switching and protecting low-voltage electrical distribution systems, including main incomers and high-performance distribution feeders.
The circuit breaker has a rated uninterrupted current of 800 A and uses a PR121/P-LSI R800 electronic overcurrent release.
The PR121/P-LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.
The E3V 800 has an ultimate short-circuit breaking capacity of 130 kA at 380–440 V AC and 100 kA at 500–690 V AC.
The 1SDA056529R1 is a three-pole fixed air circuit breaker equipped with horizontal rear terminals for integration into compatible low-voltage switchboards.
ABB SACE Emax air circuit breakers are designed for dependable switching and protection in demanding low-voltage power distribution systems, combining high short-circuit performance, adjustable electronic protection and robust construction for industrial and commercial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.