ABB 1SDA056501R1 is a SACE Emax E3H 3200 A three-pole fixed air circuit breaker with rear horizontal terminals and a PR122/P-LSIG electronic trip unit for high-current low-voltage power distribution protection.
£22,151.74
The ABB 1SDA056501R1 is a high-performance SACE Emax E3H air circuit breaker (ACB) designed for switching and protection in high-current low-voltage electrical distribution systems. Identified as E3H3200 PR122/P-LSIG In=3200A 3P F HR, this three-pole fixed circuit breaker combines a 3200 A rated current with the advanced ABB PR122/P-LSIG electronic overcurrent release.
As part of the ABB SACE Emax / New Emax range, the E3H3200 is engineered for demanding industrial, commercial and infrastructure power distribution applications. Its PR122/P-LSIG electronic trip unit provides long-time, short-time, instantaneous and ground-fault protection, helping safeguard cables, busbars, transformers and connected equipment against overloads, short circuits and earth faults.
This version features a three-pole fixed construction with rear horizontal terminals for permanent installation within low-voltage switchboards. With a rated uninterrupted current of 3200 A, rated operational voltage up to 690 V AC and an ultimate short-circuit breaking capacity of 100 kA at 400 V AC, it is suited to high-power distribution systems where dependable protection and substantial fault-current interruption capability are required.
Air circuit breakers such as the ABB E3H3200 provide switching and automatic protection for high-current low-voltage electrical distribution systems. The PR122/P electronic release continuously monitors electrical conditions and provides configurable protection functions to help safeguard cables, busbars, transformers and downstream equipment against damaging overload and fault currents.
The LSIG configuration combines long-time overload protection, short-time selective short-circuit protection, instantaneous short-circuit protection and ground-fault protection. Together with the E3H breaker’s high short-circuit performance, this makes the 1SDA056501R1 suitable for main distribution applications where protection coordination, reliability and high fault-current interruption capability are important.
| Series | SACE Emax / New Emax |
|---|---|
| ABB product group | 310513-New Emax |
| Order code | 1SDA056501R1 |
| Product type | Air circuit breaker |
| Frame | E3H |
| Short-circuit performance level | H |
| Rated current | 3200 A |
| Rated uninterrupted current | 3200 A |
| Rated operational current | 3200 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 12 kV |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | PR122/P-LSIG |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and ground fault (LSIG) |
| Overload release setting range | 1280–3200 A |
| Ultimate short-circuit breaking capacity | 100 kA at 400 V AC |
| Service short-circuit breaking capacity | 85 kA at 400 V AC |
| Rated short-time withstand current | 75 kA for 1 s; 65 kA for 3 s |
| Mounting type | Fixed |
| Terminal arrangement | Rear flat horizontal |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Mechanical durability | 20,000 cycles |
| Power loss | 330 W |
| Dimensions (H × W × D) | 418 × 404 × 302 mm |
| Net weight | 60 kg |
| Standard | IEC |
| EAN | 8015644578411 |
The ABB 1SDA056501R1 is a 3200 A air circuit breaker used for switching and protecting high-current low-voltage electrical distribution circuits in industrial, commercial and infrastructure installations.
The circuit breaker has a rated uninterrupted current of 3200 A and uses the ABB SACE Emax E3H frame.
The PR122/P-LSIG electronic release provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.
This model is a three-pole fixed air circuit breaker with rear horizontal terminals for permanent installation within a low-voltage switchboard.
The E3H3200 has an ultimate short-circuit breaking capacity of 100 kA at 400 V AC, a service short-circuit breaking capacity of 85 kA at 400 V AC and a rated short-time withstand current of 75 kA for 1 s.
ABB SACE Emax air circuit breakers are designed for dependable switching and protection of low-voltage power distribution systems, combining high current ratings, advanced electronic protection and robust construction for demanding industrial, commercial and infrastructure installations.