1SDA056444R1 ABB E3H2000 PR122/P-LSI 2000 A 4-Pole Fixed Air Circuit Breaker

1SDA056444R1 ABB E3H2000 PR122/P-LSI 2000 A 4-Pole Fixed Air Circuit Breaker

ABB 1SDA056444R1 E3H2000 is a 2000 A four-pole fixed SACE Emax air circuit breaker with a PR122/P-LSI electronic overcurrent release, LSI protection, rear horizontal terminals and up to 100 kA ultimate short-circuit breaking capacity for demanding low-voltage power distribution.

SKU: 1SDA056444R1MPN: 1SDA056444R1
Price
List Price £21,596.49 ex VAT
Your Price (ex VAT) Save 25%
£16,197.37 25% OFF
You save £5,399.12 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £16,197.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£16,197.37

Why Choose the ABB 1SDA056444R1 E3H2000 Air Circuit Breaker?

The ABB 1SDA056444R1 is a high-performance SACE Emax E3H air circuit breaker (ACB) designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the ABB New Emax E3 series, this four-pole fixed circuit breaker combines a 2000 A rated current with the PR122/P-LSI electronic overcurrent release for dependable protection of industrial, commercial and infrastructure power installations.

The E3H2000 is equipped with ABB's PR122/P-LSI R2000 electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection. This LSI configuration supports selective coordination and effective fault protection without integrated ground-fault protection, making it suitable for high-current distribution systems requiring advanced electronic overcurrent protection.

With a 2000 A rated uninterrupted current, four-pole fixed construction and rear flat horizontal terminals, the 1SDA056444R1 is engineered for permanent integration into low-voltage switchboards. The E3H performance level provides an ultimate short-circuit breaking capacity of 100 kA from 220–500 V AC and 85 kA at 660–690 V AC, supporting installations with substantial prospective fault currents.

Key Advantages

  • High-performance ABB SACE Emax E3H air circuit breaker for demanding low-voltage power distribution.
  • 2000 A rated uninterrupted current for high-current industrial, commercial and infrastructure applications.
  • PR122/P-LSI electronic overcurrent release for advanced circuit protection.
  • LSI functionality provides long-time, short-time and instantaneous protection for effective system coordination.
  • Four-pole construction supports three-phase systems requiring neutral switching.
  • Ultimate short-circuit breaking capacity of up to 100 kA for high-fault-level installations.
  • Fixed mounting with rear flat horizontal terminals supports permanent switchboard integration.
  • Four auxiliary contacts with open/closed position indication support circuit-breaker monitoring and control.

Key Features

  • ABB SACE Emax E3H2000 series air circuit breaker.
  • 2000 A rated uninterrupted current.
  • Four-pole configuration.
  • Fixed circuit-breaker version.
  • Rear flat horizontal terminals.
  • PR122/P-LSI R2000 electronic overcurrent release.
  • LSI protection covering long-time, short-time and instantaneous functions.
  • Rated operational voltage up to 690 V AC.
  • Rated insulation voltage of 1000 V.
  • Rated impulse withstand voltage of 12 kV.
  • Ultimate short-circuit breaking capacity of up to 100 kA.
  • Rated short-time withstand current of 75 kA for 1 s.

Advanced Protection for High-Current Power Distribution

Air circuit breakers such as the ABB E3H2000 provide switching, isolation and protection for high-current low-voltage distribution systems. The electronic trip unit monitors current conditions and enables the breaker to interrupt overload and short-circuit faults, helping protect busbars, cables, transformers and connected electrical equipment from potentially damaging overcurrents.

The integrated PR122/P-LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. Combined with the E3H breaker's 2000 A current rating, four-pole construction, ultimate breaking capacity of up to 100 kA and fixed configuration, the 1SDA056444R1 is particularly suited to main distribution circuits requiring dependable electronic protection, selective coordination and high fault-clearing performance.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Manufacturing and process plants.
  • Commercial and large-building electrical distribution.
  • Main incomer and high-current feeder protection.
  • Three-phase four-wire electrical distribution systems.
  • Generator and transformer distribution circuits.
  • Power control centres and fixed switchgear assemblies.
  • Infrastructure and utility installations with high prospective fault currents.

Technical Specifications

Product group 310513-New Emax
Series SACE Emax / New Emax E3
ABB order code 1SDA056444R1
Product type Air circuit breaker
Frame / performance type E3H
Short-circuit performance level H
Rated current (In) 2000 A
Rated operational current (Ie) 2000 A
Rated uninterrupted current (Iu) 2000 A
Number of poles 4
Mounting version Fixed
Terminal arrangement Rear flat horizontal terminals
Trip unit PR122/P-LSI R2000 electronic overcurrent release
Release type Electronic
Protection functions LSI – long-time, short-time and instantaneous
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu), 220–500 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu), 660–690 V AC 85 kA
Rated service short-circuit breaking capacity (Ics), 220–690 V AC 85 kA
Rated short-time withstand current (Icw) 75 kA for 1 s; 65 kA for 3 s
Current type AC
Power loss 130 W
Electrical durability 9,000 cycles at ≤440 V AC; 9,000 cycles at 500–690 V AC
Electrical operating frequency 20 cycles per hour
Mechanical durability 20,000 cycles
Mechanical operating frequency 60 cycles per hour
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Standards IEC
Dimensions (H × W × D) 418 × 530 × 302 mm
Net weight 76 kg
EAN 8015644577841
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA056444R1 used for?

The ABB 1SDA056444R1 is a fixed air circuit breaker used for switching and protecting high-current low-voltage electrical distribution circuits against overload and short-circuit conditions.

What is the rated current of the ABB E3H2000 1SDA056444R1?

The circuit breaker has a rated uninterrupted current of 2000 A, making it suitable for demanding industrial, commercial and infrastructure power distribution applications.

What protection unit is fitted to the ABB 1SDA056444R1?

The 1SDA056444R1 is fitted with an ABB PR122/P-LSI R2000 electronic overcurrent release, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What does LSI protection mean?

LSI denotes long-time overload protection, short-time short-circuit protection and instantaneous short-circuit protection. Unlike an LSIG configuration, this LSI version does not include integrated ground-fault protection.

What is the short-circuit breaking capacity of the ABB E3H2000?

The E3H2000 1SDA056444R1 provides an ultimate short-circuit breaking capacity of 100 kA from 220–500 V AC and 85 kA at 660–690 V AC, with a rated service short-circuit breaking capacity of 85 kA across the specified operating-voltage range.

Is the ABB 1SDA056444R1 fixed or withdrawable?

The 1SDA056444R1 is a four-pole fixed air circuit breaker with rear flat horizontal terminals for permanent integration into compatible low-voltage switchboards.

Trusted ABB Power Distribution Technology

ABB SACE Emax air circuit breakers provide robust high-current switching and advanced electronic protection for demanding low-voltage distribution systems, combining high short-circuit performance with dependable protection and practical switchgear integration.