1SDA056372R1 ABB E3H1250 PR122/P-LSI 1250A 3-Pole Fixed Air Circuit Breaker

1SDA056372R1 ABB E3H1250 PR122/P-LSI 1250A 3-Pole Fixed Air Circuit Breaker

ABB 1SDA056372R1 is a SACE Emax E3H1250 three-pole fixed air circuit breaker rated at 1250 A with rear horizontal terminals and a PR122/P-LSI R1250 electronic overcurrent release for high-performance low-voltage circuit protection.

SKU: 1SDA056372R1MPN: 1SDA056372R1
Price
List Price £12,845.99 ex VAT
Your Price (ex VAT) Save 25%
£9,634.49 25% OFF
You save £3,211.50 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,634.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,634.49

Why Choose the ABB E3H1250 PR122/P-LSI 1250A 3-Pole Air Circuit Breaker?

The ABB E3H1250 PR122/P-LSI, order code 1SDA056372R1, is a high-performance SACE Emax air circuit breaker (ACB) designed for switching and protection in demanding low-voltage electrical distribution systems. As part of the ABB SACE Emax E3 series, this three-pole fixed circuit breaker combines a 1250 A rated current with the PR122/P-LSI R1250 electronic overcurrent release.

The PR122/P-LSI trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. This LSI configuration supports selective coordination and dependable protection against sustained overloads and short-circuit faults, making the breaker suitable for industrial, commercial and infrastructure power distribution applications.

With a 1250 A rated current, three-pole configuration, fixed construction and rear horizontal terminals, the E3H1250 is designed for permanent integration into low-voltage switchboards. Its E3H high-performance configuration provides substantial short-circuit interruption capability for electrical networks with demanding prospective fault levels.

Key Advantages

  • High-performance ABB SACE Emax E3H air circuit breaker for demanding low-voltage distribution systems.
  • 1250 A rated current for high-current electrical distribution applications.
  • Three-pole configuration for three-phase electrical systems.
  • Advanced PR122/P-LSI R1250 electronic overcurrent release.
  • Long-time, short-time and instantaneous overcurrent protection.
  • E3H high-breaking-capacity performance level for networks with substantial prospective fault currents.
  • Fixed construction for permanent switchboard integration.
  • Rear horizontal terminals provide a practical connection arrangement for switchboard busbar systems.

Key Features

  • ABB SACE Emax E3H1250 air circuit breaker.
  • 1250 A rated current.
  • Three-pole (3P) configuration.
  • PR122/P-LSI electronic overcurrent release.
  • R1250 release rating.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Fixed (F) installation.
  • Rear horizontal (HR) terminals.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • Designed for demanding industrial and commercial low-voltage power distribution.

High-Performance Circuit Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax E3H1250 provide switching, isolation and overcurrent protection for important low-voltage distribution circuits. The electronic trip unit monitors current conditions and initiates circuit-breaker operation when configured protection thresholds are exceeded, helping protect cables, switchgear and connected electrical equipment against damaging overloads and short circuits.

The PR122/P-LSI release provides three complementary levels of overcurrent protection. Long-time protection responds to sustained overloads, short-time protection supports selective fault clearing and coordination with downstream protective devices, while instantaneous protection provides rapid interruption of severe short-circuit currents. Combined with the E3H breaker's high short-circuit performance, the 1SDA056372R1 is well suited to demanding power distribution networks.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution systems.
  • Transformer and generator distribution systems.
  • Commercial and infrastructure electrical installations.
  • Manufacturing and process facilities.
  • Incomer and high-capacity feeder protection.

Technical Specifications

Series SACE Emax E3
ABB order code 1SDA056372R1
Product group 310513-New Emax
Product type Air circuit breaker
Frame / performance level E3H
Rated current 1250 A
Number of poles 3
Version Fixed
Terminal arrangement Rear horizontal
Trip unit PR122/P-LSI
Release rating R1250
Release type Electronic overcurrent release
Protection functions LSI
Long-time protection L
Short-time protection S
Instantaneous protection I
Rated operational voltage Up to 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 12 kV
Rated ultimate short-circuit breaking capacity at 400–415 V AC 100 kA
Rated service short-circuit breaking capacity at 400–415 V AC 85 kA
Rated short-time withstand current (1 s) 75 kA
Rated short-time withstand current (3 s) 65 kA
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Net weight 72 kg
EAN 8015644577124
Customs tariff number 85362090

Frequently Asked Questions

What is the ABB 1SDA056372R1 used for?

The ABB 1SDA056372R1 is a SACE Emax E3H1250 air circuit breaker designed for switching and protecting demanding low-voltage electrical distribution circuits, including industrial incomers, feeders and main distribution systems.

What is the rated current of the ABB E3H1250 PR122/P-LSI?

The E3H1250 is rated at 1250 A and is configured as a three-pole circuit breaker for three-phase low-voltage power distribution.

What protection functions does the PR122/P-LSI trip unit provide?

The PR122/P-LSI electronic overcurrent release provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection.

What is the breaking capacity of the ABB E3H1250?

The E3H performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 400–415 V AC and a rated service short-circuit breaking capacity of 85 kA at 400–415 V AC.

Is the ABB 1SDA056372R1 fixed or withdrawable?

The 1SDA056372R1 is a fixed three-pole air circuit breaker equipped with rear horizontal terminals for permanent integration into low-voltage switchboards and power distribution equipment.

Trusted for Critical Power Distribution

ABB SACE Emax air circuit breakers are designed for dependable protection and control of low-voltage electrical distribution systems, combining high-current switching capability with advanced electronic overcurrent protection for demanding industrial, commercial and infrastructure applications.