ABB 1SDA056360R1 E3H800 is an 800 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LI electronic overcurrent release and up to 100 kA ultimate short-circuit breaking capacity for demanding low-voltage power distribution.
£10,853.47
The ABB 1SDA056360R1 is a high-performance SACE Emax E3H air circuit breaker (ACB) moving part designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the ABB New Emax E3 series, this four-pole withdrawable circuit breaker combines an 800 A rated current with the PR121/P-LI electronic overcurrent release for dependable protection of industrial, commercial and infrastructure power installations.
The E3H800 is equipped with ABB's PR121/P-LI R800 electronic trip unit, providing long-time overload and instantaneous short-circuit protection. This LI protection configuration provides essential electronic overcurrent protection, while the four-pole construction supports switching and protection across three phase conductors and the neutral conductor in compatible low-voltage distribution systems.
With an 800 A rated uninterrupted current, four-pole withdrawable moving-part construction and an ultimate short-circuit breaking capacity of 100 kA at 400 V AC, the 1SDA056360R1 is engineered for switchboards with substantial prospective fault currents. Its withdrawable construction allows the moving part to be removed from the corresponding fixed cradle for inspection, servicing or replacement.
Air circuit breakers such as the ABB E3H800 provide switching and protection for demanding low-voltage distribution systems. The electronic trip unit monitors current conditions and enables the breaker to interrupt overload and short-circuit faults, helping protect busbars, cables, transformers and connected electrical equipment from potentially damaging overcurrents.
The integrated PR121/P-LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. Combined with the E3H breaker's 800 A current rating, four-pole construction, ultimate breaking capacity of up to 100 kA and withdrawable design, the 1SDA056360R1 is particularly suited to main distribution circuits requiring dependable protection, high short-circuit performance and maintainable switchgear.
| Product group | 310513-New Emax |
|---|---|
| Series | SACE Emax / New Emax E3 |
| ABB order code | 1SDA056360R1 |
| Product type | Air circuit breaker moving part |
| Frame / performance type | E3H |
| Short-circuit performance level | H |
| Rated current (In) | 800 A |
| Rated operational current (Ie) | 800 A |
| Rated uninterrupted current (Iu) | 800 A |
| Number of poles | 4 |
| Version | Withdrawable (W) |
| Configuration | Moving part (MP) |
| Trip unit | PR121/P-LI R800 electronic overcurrent release |
| Release type | Electronic |
| Protection functions | LI – long-time and instantaneous |
| Instantaneous short-circuit protection setting range | 1200–12000 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu), 220–500 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu), 660–690 V AC | 85 kA |
| Rated service short-circuit breaking capacity (Ics), 220–690 V AC | 85 kA |
| Rated short-time withstand current (Icw) | 75 kA for 1 s; 65 kA for 3 s |
| Current type | AC |
| Power loss | 36 W |
| Electrical durability | 12,000 cycles at ≤440 V AC; 12,000 cycles at 500–690 V AC |
| Electrical operating frequency | 20 cycles per hour |
| Mechanical durability | 20,000 cycles |
| Mechanical operating frequency | 60 cycles per hour |
| Auxiliary contacts | 4 (2 NO + 2 NC) |
| Position indication | Circuit breaker open / closed |
| Integrated motor drive | No |
| Motor drive | Optional |
| Degree of protection | IP2X |
| Standards | IEC |
| Dimensions (H × W × D) | 461 × 558 × 396.5 mm |
| Net weight | 81 kg |
| EAN | 8015644577001 |
| Customs tariff number | 85362090 |
The ABB 1SDA056360R1 is a withdrawable air circuit breaker moving part used for switching and protecting low-voltage electrical distribution circuits against overload and short-circuit conditions.
The circuit breaker has a rated uninterrupted current of 800 A, making it suitable for demanding industrial and commercial power distribution applications.
The 1SDA056360R1 is fitted with an ABB PR121/P-LI R800 electronic overcurrent release, providing long-time overload and instantaneous short-circuit protection.
LI denotes long-time overload protection and instantaneous short-circuit protection, providing electronic overcurrent protection for low-voltage distribution circuits.
The E3H800 1SDA056360R1 provides an ultimate short-circuit breaking capacity of 100 kA from 220–500 V AC and 85 kA at 660–690 V AC, with a rated service short-circuit breaking capacity of 85 kA across the specified operating-voltage range.
The 1SDA056360R1 is a four-pole withdrawable circuit-breaker moving part designed for use with a compatible ABB SACE Emax fixed part within low-voltage switchgear.
ABB SACE Emax air circuit breakers provide robust switching and electronic protection for demanding low-voltage distribution systems, combining high short-circuit performance with dependable protection and maintainable withdrawable switchgear configurations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.