Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB E3S3200PR121/P-LSIG is a 3200 A four-pole withdrawable SACE Emax air circuit breaker moving part with a PR121/P-LSIG R3200 electronic trip unit providing long-time, short-time, instantaneous and earth-fault protection.
£28,994.45
The ABB E3S3200PR121/P-LSIG is a high-performance 3200 A four-pole air circuit breaker moving part designed for reliable switching and comprehensive overcurrent protection in demanding low-voltage power distribution systems. Part of the established ABB SACE Emax New Emax series, this E3S configuration combines high-current switching capability with the PR121/P-LSIG electronic overcurrent release.
The PR121/P-LSIG trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. These LSIG functions help safeguard cables, busbars, switchboards and connected electrical equipment against sustained overloads, severe short-circuit currents and earth faults while supporting selective protection and coordination across complex electrical distribution networks.
With a rated uninterrupted current of 3200 A, a four-pole withdrawable moving-part configuration and a PR121/P-LSIG R3200 overcurrent release, ABB order code 1SDA056330R1 is designed for compatible SACE Emax withdrawable switchgear. The moving part is fitted with four auxiliary contacts and circuit-breaker open/closed position indication for signalling, monitoring and control integration.
Air circuit breakers such as the ABB E3S3200 provide switching and overcurrent protection for high-current low-voltage distribution circuits. The electronic trip release monitors circuit conditions and initiates breaker operation when configured protection thresholds are exceeded, helping protect cables, busbars, switchboards and connected electrical equipment against damaging overload, short-circuit and earth-fault currents.
The PR121/P-LSIG release combines four essential protection functions within a single electronic trip system. Together with the 3200 A four-pole E3S configuration, 75 kA short-circuit breaking capacity and service-friendly withdrawable construction, this moving part is well suited to critical main distribution and high-current feeder applications requiring integrated earth-fault protection.
| Series | SACE Emax / New Emax |
|---|---|
| ABB order code | 1SDA056330R1 |
| Extended product type | E3S3200PR121/P-LSIGIn=3200A4pWMP |
| Product type | Air circuit breaker moving part |
| Frame | E3S |
| Short-circuit performance level | S |
| Rated current | 3200 A |
| Rated operational current | 3200 A |
| Rated uninterrupted current | 3200 A |
| Number of poles | 4 |
| Current type | AC |
| Rated operational voltage | 690 V AC |
| Rated voltage | 690 V |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 12 kV |
| Rated ultimate short-circuit breaking capacity | 75 kA at 220–690 V AC |
| Rated service short-circuit breaking capacity | 75 kA at 220–690 V AC |
| Rated short-time withstand current | 75 kA for 1 s; 65 kA for 3 s |
| Execution | Withdrawable moving part (WMP) |
| Trip unit | PR121/P-LSIG |
| Release type | Electronic |
| Overcurrent release rating | R3200 |
| Protection functions | L, S, I and G |
| Long-time overload protection | Yes |
| Short-time short-circuit protection | Yes |
| Instantaneous short-circuit protection | Yes |
| Integrated earth-fault protection | Yes |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Power loss | 570 W |
| Electrical durability | 6000 cycles at Ue ≤ 440 V; 5000 cycles at Ue 500–690 V |
| Maximum electrical operating frequency | 20 cycles per hour |
| Mechanical durability | 20,000 cycles |
| Maximum mechanical operating frequency | 60 cycles per hour |
| Dimensions (W × H × D) | 558 × 461 × 396.5 mm |
| Net weight | 81 kg |
| EAN | 8015644576707 |
| HS code | 85362090 |
| Standard | IEC |
It is a 3200 A four-pole air circuit breaker moving part designed for switching and protecting high-current low-voltage AC power distribution circuits in compatible ABB SACE Emax withdrawable switchgear.
The PR121/P-LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
The E3S3200 provides rated ultimate and service short-circuit breaking capacities of 75 kA from 220 to 690 V AC, together with rated short-time withstand currents of 75 kA for 1 s and 65 kA for 3 s.
ABB order code 1SDA056330R1 is a four-pole withdrawable moving part for a compatible SACE Emax E3S circuit-breaker installation.
Yes. The G function of the PR121/P-LSIG electronic release provides integrated earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
ABB SACE Emax air circuit breakers are widely used in industrial and commercial low-voltage distribution systems, combining robust high-current switching technology with configurable electronic protection and service-friendly withdrawable construction for demanding electrical installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.