ABB 1SDA056317R1 E3S 3200 four-pole fixed air circuit breaker rated at 3200 A with rear horizontal terminals and a PR122/P-LSIG electronic trip unit providing comprehensive LSIG protection for high-current low-voltage power distribution.
£23,853.79
The ABB 1SDA056317R1 is a high-performance SACE Emax E3S air circuit breaker designed for switching and protection in demanding high-current low-voltage power distribution systems. Rated at 3200 A, this four-pole fixed circuit breaker incorporates ABB's advanced PR122/P-LSIG electronic overcurrent release for comprehensive protection of industrial, commercial and infrastructure electrical networks.
Part of the proven ABB SACE Emax E3 series, the E3S 3200 combines substantial current-handling capability with strong short-circuit performance. The S performance level provides rated ultimate and service short-circuit breaking capacities of 75 kA across specified AC voltages up to 690 V AC, making the breaker suitable for demanding main distribution and high-fault-level applications.
The PR122/P-LSIG release provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. This version features a four-pole fixed configuration with rear horizontal terminals and is fitted with four auxiliary contacts plus circuit-breaker open/closed position indication for integration into low-voltage switchboards and power distribution systems.
Air circuit breakers such as the ABB E3S 3200 provide switching, isolation and automatic protection for high-current low-voltage distribution circuits. The electronic release monitors circuit conditions and commands the breaker to open when configured overload, short-circuit or earth-fault thresholds are reached, helping protect conductors, switchgear and connected electrical equipment.
The PR122/P-LSIG release combines long-time, short-time, instantaneous and earth-fault protection functions for comprehensive protection and coordination within complex electrical networks. Together with the E3S breaker's 75 kA short-circuit performance and fixed rear-terminal arrangement, the 1SDA056317R1 is well suited to critical switchboards requiring dependable high-current protection.
| Series | SACE Emax E3 |
|---|---|
| ABB order code | 1SDA056317R1 |
| Product type | Air circuit breaker |
| Frame | E3 |
| Short-circuit performance level | S |
| Rated current (In) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Rated operational current (Ie) | 3200 A |
| Number of poles | 4 |
| Current type | AC |
| Trip unit | PR122/P-LSIG |
| Release type | Electronic |
| Protection functions | LSIG – long-time, short-time, instantaneous and earth-fault |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 75 kA |
| Rated service short-circuit breaking capacity (Ics) at 400 V AC | 75 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 75 kA |
| Rated service short-circuit breaking capacity (Ics) at 690 V AC | 75 kA |
| Rated short-time withstand current (Icw), 1 s | 75 kA |
| Rated short-time withstand current (Icw), 3 s | 65 kA |
| Power loss | 330 W |
| Installation | Fixed |
| Terminal connection | Rear horizontal |
| Auxiliary contacts | 4 |
| Position indication | Open / closed |
| Electrical durability at ≤440 V | 6000 cycles |
| Electrical durability at 500–690 V | 5000 cycles |
| Mechanical durability | 20,000 cycles |
| Weight | 90 kg |
| EAN | 8015644576578 |
| Product group | 310513-New Emax |
The ABB 1SDA056317R1 is a SACE Emax E3S 3200 four-pole fixed air circuit breaker rated at 3200 A and equipped with a PR122/P-LSIG electronic overcurrent release.
The PR122/P-LSIG provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection functions.
The circuit breaker has a rated current and rated uninterrupted current of 3200 A.
The E3S 3200 has rated ultimate and service short-circuit breaking capacities of 75 kA at 400 V AC, with the E3S performance level maintaining 75 kA at specified AC voltages up to 690 V.
The 1SDA056317R1 is a fixed four-pole circuit breaker with rear horizontal terminals, designed for permanent installation within compatible low-voltage switchboards.
ABB SACE Emax air circuit breakers provide dependable high-current switching and protection for demanding low-voltage power distribution systems, combining advanced electronic protection, high short-circuit performance and robust switchboard construction.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.